QIN Qin, WANG Dandan, TONG Minghui. Application of shear wave elastography in extraocular myopathies of thyroidophthalmopathy[J]. Journal of Clinical Ultrasound in Medicine, 2021,23(2):101-104.
QIN Qin, WANG Dandan, TONG Minghui. Application of shear wave elastography in extraocular myopathies of thyroidophthalmopathy[J]. Journal of Clinical Ultrasound in Medicine, 2021,23(2):101-104. DOI: 10.16245/j.cnki.issn1008-6978.2021.02.009.
Objective To evaluate the thickness and mean Young’s modulus(Emean) of four extraocular muscles in thyroid associated ophthalmopathy(TAO) by shear wave elastography(SWE)
and to explore SWE diagnostic value for TAO.Methods A random collection of 60 TAO patients hospitalized in the endocrinology department of our hospital were divided into two subgroups:38 patients in TAO edema stage(group A) and 22 patients in TAO fibrosis stage(group B)
50 healthy volunteers matching age and sex during the same period were selected as the control group.High-frequency ultrasound was used to measure the thickness of extraocular muscles
and SWE was used to measure Emean of extraocular muscles
the difference of above parameters among three groups were compared.The ROC curve was drawn
and the diagnostic efficiency of Tao was analyzed.Results The thickness and Emean value of extraocular muscles in the group A and group B were higher than those in the control group(both P<0.05).The Emean values of the four extraocular muscles in the control group
group A
and group B gradually increased(P<0.05)
and there was no significant difference in thickness between the group A and group B.The Emean cut-off value of superior
inferior
lateral and medial rectus for diagnosing TAO were 9.85 kPa
9.65 kPa
9.85 kPa
9.65 kPa
respectively
the sensitivity were 86%
78%
82%
80%
and the specificity were 90%
95%
95%
98%.Conclusion SWE can quantitatively assess the elasticity of extraocular muscles
which provide a reference for clinical diagnosis of extraocular muscle diseases in TAO.