Application value of virtual touch tissue imaging quantification technique in detecting acute liver failure and evaluating the effect of preventive medication in rats
DU Yang, TU Jizheng, HAN Mei, et al. Application value of virtual touch tissue imaging quantification technique in detecting acute liver failure and evaluating the effect of preventive medication in rats[J]. Journal of Clinical Ultrasound in Medicine, 2020,22(10):721-724.
DU Yang, TU Jizheng, HAN Mei, et al. Application value of virtual touch tissue imaging quantification technique in detecting acute liver failure and evaluating the effect of preventive medication in rats[J]. Journal of Clinical Ultrasound in Medicine, 2020,22(10):721-724. DOI: 10.16245/j.cnki.issn1008-6978.2020.10.001.
Objective To investigate the clinical application value of virtual touch tissue imaging quantification(VTIQ) technique in detecting acute liver failure(ALF)and evaluating the effect of preventive medication in rats.Methods Twenty-four male SD rats were randomly divided into the control group
the model group and the treatment group with eight rats in each group. The treatment group was treated by gavage with Medilac-S(100 mg·kg
-1
·d
-1
)after dilution
while the control group and the model group were treated with the same volume of warm normal saline for 8 d. On the 6 th and 7 th day of the experiment
the model group and the treatment group were intraperitoneally injected with TAA(200 mg·kg
-1
·d
-1
). The shear wave velocity(SWV)of liver were measured and compared among three groups before and after the establishment of the model.Taken pathological result as the golden standard
ROC curve was drawn to obtain the cut-off value for predicting ALF by SWV
and area under the curve was calculated.Results Before modeling
the SWV mean of control group
model group and treatment group were(2.43 ± 0.57)m/s
(2.61 ± 0.42)m/s and(2.71 ± 0.49)m/s
respectively
and the difference was not statistical significance. After modeling
the SWV mean of control group
model group and treatment group were(2.50±0.71)m/s
(3.56±0.48)m/s and(3.06±0.27)m/s
respectively. The SWV mean in the model group was higher than that in the control group
and the difference was statistical significance(P
<
0.05). With cut-off value of 2.83 m/s
the area under the curve
sensitivity and specificity were 0.938
100% and 75.00% in predicting ALF
respectively.Conclusion The VTIQ technique has a potential application value in predicting ALF and evaluating the effect of preventive medication.