
浏览全部资源
扫码关注微信
南京市浦口区中医院功能科
纸质出版日期:2020,
扫 描 看 全 文
[1]高翔,舒开凤,刘微微.胎心容积辅助诊断技术筛查孕中晚期胎儿心脏流出道病变的可行性[J].临床超声医学杂志,2020,22(09):655-659.
GAO Xiang, SHU Kaifeng, LIU Weiwei. Feasibility of fetal heart volume assisted diagnosis technique for screening fetal cardic outflow disease during middle and late pregnancy[J]. Journal of Clinical Ultrasound in Medicine, 2020,22(9):655-659.
[1]高翔,舒开凤,刘微微.胎心容积辅助诊断技术筛查孕中晚期胎儿心脏流出道病变的可行性[J].临床超声医学杂志,2020,22(09):655-659. DOI: 10.16245/j.cnki.issn1008-6978.2020.09.004.
GAO Xiang, SHU Kaifeng, LIU Weiwei. Feasibility of fetal heart volume assisted diagnosis technique for screening fetal cardic outflow disease during middle and late pregnancy[J]. Journal of Clinical Ultrasound in Medicine, 2020,22(9):655-659. DOI: 10.16245/j.cnki.issn1008-6978.2020.09.004.
目的分析胎心容积辅助诊断技术筛查孕中晚期胎儿心脏流出道病变的可行性。方法选取在我院行超声检查的孕中晚期单胎孕妇190例
常规行二维超声心动图检查
采集、储存胎儿心脏容积数据
然后应用胎心容积辅助诊断技术对成像进行后处理
并进行图像质量评分
比较处理前后图像质量评分的差异。应用Pearson相关分析法分析两种方法测得的主动脉和肺动脉内径之间的相关性;应用Bland-Altman检验分析两种方法的一致性
并分析观察者内和观察者间的重复性。结果 176例(92.63%)孕妇采用胎心容积辅助诊断技术获得了胎儿心脏左、右室流出道切面的清晰图像
测得主动脉和肺动脉内径;软件处理前后左室流出道和右室流出道切面图像质量评分比较差异均有统计学意义(Z=-6.958、-8.521
均P=0.000)。Pearson相关分析显示
二维超声心动图和胎心容积辅助诊断技术测得的主动脉和肺动脉内径均呈正相关(r=0.83、0.79
均P<0.05);Bland-Altman检验显示
两种方法测得主动脉和肺动脉内径的一致性较好
95%一致性界限分别为-1.18~1.01、-1.81~1.03;胎心容积辅助诊断技术测量主动脉、肺动脉内径观察者间和观察者内的组内相关系数均>0.85。结论胎心容积辅助诊断技术在孕中晚期单胎胎儿心脏流出道病变筛查中具有一定可行性
临床应用价值较好。
Objective To analyze the feasibility of fetal heart volume assisted diagnosis technique in the screening offetal cardiac outflow disease during middle and late pregnancy.Methods One hundred and ninety cases of single pregnantwomen in mid-late pregnancy were underwent ultrasonography in our hospital were selected. The routine two-dimensionalechocardiography was performed on all the fetuses
the fetal heart volume data were collected.The imaing was post-processed bythe fetal heart volume assisted diagnosis technique.Image quality score was performed and the difference of image quality scorebefore and after processing was compared.The correlation between the aortic and pulmonary artery diameters measured by thetwo methods was analyzed by Pearson correlation analysis.The consistency of the two methods was analyzed by Bland-Altmantest
and the intra observer and inter observer repeatability were analyzed as well.Results One hundred and seventy-six(92.63%)pregnant women obtained clear images of the left and right ventricular outflow tract sections of the fetal heart byfetal heart volume assisted diagnosis technique
the aortic and pulmonary artery diameters were measured.The image qualityscores of left and right ventricular outflow tract before and after processing were statistically significant(Z=-6.958
-8.521
both P=0.000).Pearson correlation analysis showed that the aortic and pulmonary artery diameters measured by two-dimensionalechocardiography and fetal heart volume assisted diagnosis technique were positively correlated(r=0.83
0.79
both P<0.05).Bland-Altman test showed suggested that the consistency of the two methods in measuring the diameters of aorta and pulmonaryartery was good.The 95% consistency limits were-1.18~1.01 and-1.81~1.03
respectively.In addition
the intraclass correlationcoefficient values of aortic diameter and pulmonary artery diameter measured by fetal heart volume assisted diagnosis technique were all >0.85.Conclusion The fetal heart volume assisted diagnosis technique has a good application value in the screening ofsingle fetal cardiac outflow disease during the middle and late pregnancy.
超声检查胎心容积辅助诊断孕中晚期胎儿心脏流出道病变
UltrasonographyFetal heart volume assisted diagnosisMiddle and late pregnancyFetusCardiac outflow disease
0
浏览量
10
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621