
浏览全部资源
扫码关注微信
陆军军医大学(第三军医大学)第一附属医院超声科
纸质出版日期:2021,
网络出版日期:2021-5-15,
扫 描 看 全 文
[1]何丽君,何芸,覃折波,等.2017欧洲抗风湿联盟类风湿关节炎超声评分法临床应用的可行性研究[J].陆军军医大学学报(原第三军医大学学报),2021,43(09):863-870.HE Lijun,HE Yun,QIN Zhebo,et al.Clinical application of 2017 EULAR for rheumatoid arthritis ultrasound scoring: a feasible study of 62 cases[J].J Amry Med Univ (J Third Mil Med Univ),2021,43(09):863-870.
HE Lijun, HE Yun, QIN Zhebo, et al. Clinical application of 2017 EULAR for rheumatoid arthritis ultrasound scoring: a feasible study of 62 cases[J]. Journal of Army Medical University, 2021,43(9):863-870.
[1]何丽君,何芸,覃折波,等.2017欧洲抗风湿联盟类风湿关节炎超声评分法临床应用的可行性研究[J].陆军军医大学学报(原第三军医大学学报),2021,43(09):863-870.HE Lijun,HE Yun,QIN Zhebo,et al.Clinical application of 2017 EULAR for rheumatoid arthritis ultrasound scoring: a feasible study of 62 cases[J].J Amry Med Univ (J Third Mil Med Univ),2021,43(09):863-870. DOI: 10.16016/j.1000-5404.202011039.
HE Lijun, HE Yun, QIN Zhebo, et al. Clinical application of 2017 EULAR for rheumatoid arthritis ultrasound scoring: a feasible study of 62 cases[J]. Journal of Army Medical University, 2021,43(9):863-870. DOI: 10.16016/j.1000-5404.202011039.
目的对比评估2017欧洲抗风湿联盟(European League Against Rheumatism,EULAR)类风湿关节炎超声评分法临床应用的可行性。方法采用横断面研究设计,纳入2017年1月至2019年2月于第一附属医院风湿免疫科确诊为类风湿关节炎(rheumatoidarthritis,RA)并行完整小关节超声检查患者62例,分析双侧手、腕、足小关节滑膜炎灰阶超声(greyscale ultrasound,GSUS)与能量多普勒超声(power Doppler ultrasound,PDUS)表现。由1名具有10年肌骨超声工作经验的高年资医师及1.5年肌骨超声工作经验的初级医师分别按照2017 EULAR评分法进行两次评分,加权kappa评价观察者内、观察间一致性。高年资医师再次按照临床应用较广泛的Szkudlarek评分法评价,χ2检验比较两种评分法。以高年资医师2017 EULAR评分为参照,计算每例患者2017 EULAR评分法关节滑膜炎GSUS、PDUS的总评分,与临床指标DAS28、ESR、CRP、RF、Anti-CCP、IL-6、TNF作相关性分析,非正态变量采用Spearman
双正态变量采用Pearson。结果与Szkudlarek评分法对比,滑膜炎GSUS 2级在近指、跖趾关节分布差异具有统计学意义(P<0.05),GSUS 3级在掌指、近指、跖趾关节差异均具有统计学意义(P<0.05);滑膜炎PDUS 1、2级在腕、掌指、近指、跖趾关节差异均具有统计学意义(P<0.05)。滑膜炎GSUS、PDUS与DAS28、ESR、CRP、IL-6呈正相关(P<0.05)。不同年资评价者滑膜炎GSUS、PDUS具有较好的观察者内、观察者间一致性,kappa值在0.494~1之间。结论2017 EULAR评分法可相对改善既往超声半定量评分法分布不均的情况,与DAS28、ESR、CRP、IL-6等临床指标呈正相关,不同经验观察者一致性较好,是值得临床应用推广的评分法。
ObjectiveTo assess the clinical feasibility of the 2017 European League Against Rheumatism (EULAR) ultrasound definition and quantification system for rheumatoid arthritis (RA) ultrasound scoring system. Methods A total of 62 RA patients diagnosed in the Department of Rheumatology and Immunology of our hospital and undergoing complete small joints ultrasonography from January 2017 to February 2019 were enrolled in this cross-sectional study. The grey scale ultrasonography (GSUS) and power Doppler ultrasonography (PDUS) of synovitis in the hands
wrist and feet were retrospectively analyzed and semi-quantitatively (grades 0~3) scored twice by a physician with 10-year experience in musculoskeletal ultrasound and a junior physician with 1.5-year experience in this aspect
respectively
according to 2017EULAR. Weighted kappa test was used to evaluate intra and inter-observer consistency. The senior physician assessed the ultrasonographical data again according to the most widely used Szkudlarek scoring. Chi-square test was used to compare the 2 scoring systems. After the 2017 EULAR scores of senior physicians were taken as reference
the scores of GSUS and PDUS were summed up to an total score
and the correlation of the GSUS
PDUS and total scores with clinical parameters were analyzed with Spearman correlation analysis for non-normally distributed variables and Pearson for binormal variable. ResultsCompared with the results of Szkudlarek method
the distributions of 2017 EULAR GSUS grade 2 in the proximal interphalangeal and metatarsophalangeal joints were of significant differences (P<0.05)
and so were those of GSUS grade 3 in the metacarpophalangeal
proximal interphalangeal and metatarsophalangeal joints (P<0.05). The PDUS differences of grade 1 and 2 in the wrist
metacarpophalangeal
proximal interphalangeal
and metatarsophalangeal joints were statistically significant (P<0.05). Both GSUS and PDUS scores were positively correlated with disease activity (DAS)28 score
erythrocyte sedimentation rate (ESR)
and levels of C-reactive protein (CRP) and IL-6 (P<0.05). There was a good consistency between different observers in 2017 EULAR GSUS and PDUS scoring
with a weighted kappa value ranging from 0.494 to 1. Conclusion2017 EULAR scoring system can relatively improve the uneven distribution of the existing semi-quantitative scoring
and the results are positively correlated with clinical indicators
such as DSA28 score
ESR
and levels of CRP and IL-6. It also has a good consistency among different observers. So it is worthy of clinical promotion.
类风湿关节炎2017欧洲抗风湿联盟滑膜炎超声评分
rheumatoid arthritis2017 EULARsynovitisultrasonographyscoring
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621