
浏览全部资源
扫码关注微信
1. 杭州市儿童医院,杭州,310014
2. 浙江省人民医院,杭州,310014
纸质出版日期:2023,
扫 描 看 全 文
蒋莹莹, 詹尧平, 徐翔翔. LIKERT 五分量表法在建立儿科人血白蛋白临床应用评价标准的应用[J]. 儿科药学杂志, 2023,29(1):1-4.
Jiang Yingying, Zhan Yaoping, Xu Xiangxiang. Establishment and Application of Clinical Evaluation Criteria for Pediatric Human Serum Albumin Based on Likert Five Subscale Metho[J]. 2023,29(1):1-4.
蒋莹莹, 詹尧平, 徐翔翔. LIKERT 五分量表法在建立儿科人血白蛋白临床应用评价标准的应用[J]. 儿科药学杂志, 2023,29(1):1-4. DOI: 10.13407/j.cnki.jpp.1672-108X.2023.01.001.
Jiang Yingying, Zhan Yaoping, Xu Xiangxiang. Establishment and Application of Clinical Evaluation Criteria for Pediatric Human Serum Albumin Based on Likert Five Subscale Metho[J]. 2023,29(1):1-4. DOI: 10.13407/j.cnki.jpp.1672-108X.2023.01.001.
目的:建立儿科人血白蛋白临床应用评价标准
并依据标准分析评价儿科人血白蛋白的临床应用现状。方法:通过LIKERT 五分量表法确定儿科人血白蛋白合理应用评价指标;根据评价指标
建立人血白蛋白临床应用评价标准;根据建立的评价标准对杭州市儿童医院2019 年6 月至2020 年5 月使用人血白蛋白的127 例非手术住院病例进行临床应用现状分析与评价。结果:根据人血白蛋白评价标准的主要指标点评127 份医嘱
主要存在与其他药物连续静脉滴注时未冲管21 例(38. 18%)、剂量或给药途径不合理18 例(32. 73%)、治疗低蛋白血症者未达到使用指征8 例( 14. 55%)、无适应证或适应证不适宜6 例(10. 91%)、滴速与溶媒不合理2 例(3. 64%)。结论:通过LIKERT 五分量表法建立儿科人血白蛋白临床应用评价标准
评价并分析人血白蛋白临床应用的不合理因素
对促进临床合理使用人血白蛋白具有一定价值。
Objective: To establish the evaluation criteria for the clinical application of human serum albumin in pediatrics
and analyze and evaluate the clinical application status of human serum albumin according to the criteria. Methods: Firstly
the evaluation index of pediatric human serum albumin rational application was determined by Likert five subscale method. Secondly
according to the evaluation index
the clinical application evaluation standard of human serum albumin was established. Finally
according to the established evaluation criteria
the clinical application status of 127 non-surgical inpatients who used human serum albumin from June 2019 to May 2020 was analyzed and evaluated. Results: According to the main indicators of human serum albumin evaluation criteria
127 medical orders were evaluated. There were 21 cases (38. 18%) of not flushing tube when continuous intravenous drip with other drugs
18 cases (32. 73%) of unreasonable dosage or administration route
8 cases (14. 55%) who did not meet the indications for the treatment of hypoproteinemia
6 cases (10. 91%) with no indication or inappropriate indication
and 2 cases (3. 64%) of unreasonable dripping speed or solvent. Conclusion: The evaluation standard of clinical application of human serum albumin in pediatrics is established by Likert five subscale method
and the unreasonable factors of clinical application of human serum albumin are evaluated and analyzed
to promote the rational use of human serum albumin in the clinic.
LIKERT 五分量表法人血白蛋白评价标准合理用药
Likert five subscale methohuman serum albuminevaluationrational use of drugs
0
浏览量
16
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621