[1]李琦,I.Riss.Express~(TM)前房植入术治疗难治性青光眼的疗效观察[J].重庆医科大学学报,2007(12):1320-1322.
LI Qi, et al. Clinical observation expressTM for refractory glaucoma[J]. Journal of Chongqing Medical University, 2007,(12):1320-1322.
[1]李琦,I.Riss.Express~(TM)前房植入术治疗难治性青光眼的疗效观察[J].重庆医科大学学报,2007(12):1320-1322. DOI: 10.13406/j.cnki.cyxb.2007.12.030.
LI Qi, et al. Clinical observation expressTM for refractory glaucoma[J]. Journal of Chongqing Medical University, 2007,(12):1320-1322. DOI: 10.13406/j.cnki.cyxb.2007.12.030.
目的:探讨一种新型的房水引流装置Express
TM
前房植入在治疗难治性青光眼的临床效果。方法:对35例(41只眼)难治性青光眼患者施行Express
TM
前房植入术
术中将ExpressTM值于巩膜瓣下
部分顽固性病例联合应用丝裂霉素或5-Fu
术后监测眼压、视力、视野情况和手术并发症情况。结果:41例难治青光眼
术后半年平均眼压(14.65±1.96)mmHg;一年平均眼压(13.81±1.91)mmHg。术后12个月
所有青光眼患者术后眼压与术前相比
有显著性差异
41例眼术前、术后视力无明显改变
完全成功33例占80%
总手术成功率90.2%(37/41)
本组失败4例
为眼压控制制不好或视野损伤加重
再次植入Express
TM
或行睫状体冷凝或小梁切除手术。并发症:有3例浅前房、2例短暂性眼压升高
无排斥反应和严重并发症。结论:Express
TM
前房植入术是治疗难治性青光眼的安全而有效术式。
Objective:To study and evaluate the outcome of Express
TM
Claucoma Valve Implantation for refractory glaucoma. Methods:Cases series included the eyes of Caucasian patients with refractory glaucoma
operated between 01.2003—10.2004. There were 41 eyes. The Ex-PRESS
TM
devices were inserted under the sclera flap and into the anterior chamber.If necessary anti-metabolile (MMc or 5-Fu) was used under the sclera flap before injecting the device. Each patient underwent ophthalmic examinations (Vision
IOP
visual field
gonioscopy
cup/disc ratio) before and after the operation. The longest postoperative follow-up period was 12 months. Resultes:The IOP decreased from 24.1±4.62mm Hg pre-operatively to 14.65±1.96mmHg at 26 weeks amt 13.81±1.91mmHg at one year. Success rate was 90.2% (IOP below 20 mm Hg with or without drugs). Complete success was 80% (IOP below 20 mm Hg without anti-glaucoma drops or medications). In 4 eyes IOP was not controlled with eyes drops
and the eves had already been re-operated. 3 cases had an athalamy in anterior chamber but recovered soon by treatment. None of the patients developed infection or irreversible damage to the eye. No case was found to have erosion. Conclusions:the safety and efficacy of the device ureter a sclera flap have been demonstrated in glaucoma surgery in this study.
ExpressTM前房植入术难治性青光眼
refraetory GlaucomaExpressTM