目的探讨HL-1改变兔肝脏组织声学环境的可行性及机制。方法实验组用HL-1静脉输入20min
约1h后解剖
取小块肝脏组织送病理
然后即行肝脏FU定点损伤及靶区组织温度测量
辐照时间为3s、6s、9s、12s、15s
功率3.04W、频率11MHz
脉冲1000Hz
实验后每只兔肝取2~3块未损伤组织测量其密度;对照组以Saline代替HL-1
其余步聚同实验组。结果两组温度变化趋势基本相同
但实验组各个辐照时间温度上升值均大于对照组(P<0.05)。大体观实验组兔肝脏外观呈粉红色
可见类似脂肪肝似的脂质沉着
病理检查肝细胞和肝血窦内均见大量脂质体沉积
肝血窦腔隙及中央静脉缩小
切面有“实变”感;肝组织密度测量实验组和对照组分别为1.1217±0.0281g.cm-3和1.0547±0.0388g.cm-3(P<0.01)。结论HL-1静脉输入可以导致肝脏组织结构发生相应的改变、加速超声能量在靶区组织处的沉积、提高组织的温升效果
因而改变了肝脏组织的AET。
Objective:To explore the feasibility and mechanism on changing acoustic environment in tissue (AET) of rabbit liver by HL-1 intravenous injection.Methods:10 New Zealand rabbits were randomly divided into two groups
treatment and control group with 5 rabbits respectively.Before rabbit livers were ablated in vitro by using focused ultrasound(FU)(3.04W
11MHz)
HL-1 was injected intravenously via rabbit ear marginal vine for 20 minutes.Rabbits were sacrificed by excessive anesthesia after 1 hour
and small pieces of liver tissue were cut for pathological exammation.Rabbits liver were ablated with FU in the manners of dot scan in different preplanned liver areas with various treatment time of 3s
6s
9s
12s and 15s
and its temperature in each dot was measured immediately after ablation.2 to 3 pieces of non-damaged tissues in each liver were chosen to measure its density after trial.All processes were the same as those of experiment group except replacing HL-1 with saline in control group.Results:Similar time-temperature curve showed in two groups except the temperature was higher in every dot in treatment group than that of control group( P <0.05).Pink
tumidity and lipid deposition were seen in the liver of treatment group.Pathological exammation showed augmentation
swelling and disorders of hepatocytes in treatment group;hepatic sinusoids and central vein of liver shrunk evidently.“Consolidation configuration” appearance was found in tissue section.Abundant liposome deposited in hepatocytes and sinusoids and accumulated in sinusoids in treatment group.The densities of liver tissues were 1.1217±0.0281 g.cm -3 and 1.0547±0.0388g.cm -3 ( P <0.01) in treatment and control group respectively.Conclusion:HL-1 can accumulate massively in rabbit liver and change its AET by intravenous injection
which can enhance the deposition of ultrasonic energy in target tissue and speed up temperature rising.
HL-1肝脏组织声学环境聚焦超声温升密度
HL-1Rabbit liverAcoustic environment in tissue (AET)Focused ultrasound (FU)Temperature risingDensity