Luo Chunli, et al. A STUDY OF URINARY MICROAMOUNT HEMOGLOBIN BY THE USE OF LATEX AGGLUTINATION TEST[J]. Journal of Chongqing Medical University, 1994,(2).
Luo Chunli, et al. A STUDY OF URINARY MICROAMOUNT HEMOGLOBIN BY THE USE OF LATEX AGGLUTINATION TEST[J]. Journal of Chongqing Medical University, 1994,(2).DOI:
method of urinary microamount hemoglobin determination by the use of latex agglutinationtest was reported
The rabbits were immunited by the specific Hb A antigen then isolated fromhuman red blood cell. The specific antibody was acquired sensitized by latex. The result showed thatthe lowest detectable level of microamount hemoglobin in urinary was 150μg/ml which was inaccordance with that of Japan Yiteng report. The slide agglutination was used in the experiment
theresul will be acquired within 5 min. The method is simple
rapid
sensitive
accurate and suitable forclinical applications and it is a supplement of urinary instrument.The false negative and positivewere also studied.