王世科, 郭大静, 张维, 等. T1WI 3D-VISTA在大脑中动脉狭窄中的诊断价值[J]. 重庆医科大学学报, 2018,43(8):1067.
Wang Shike, Guo Dajing, Zhang Wei, et al. Diagnostic value of T1WI 3D volumetric isotropic TSE acquisition in middle cerebral artery stenosis[J]. Journal of Chongqing Medical University, 2018,43(8):1067.
目的:探讨T1加权三维容积各向同性快速自旋回波成像(T1-weighted 3D-volumetric isotropic TSE acquisition,T1WI 3D-VISTA)在大脑中动脉(middle cerebral artery,MCA)狭窄中的诊断价值。方法:回顾性分析本院2016年5月至2017年7月因怀疑MCA狭窄行磁共振时间飞跃法血管成像(time of flight magnetic resonance angiography,TOF-MRA)和T1WI 3D-VISTA检查并经数字减影血管造影(digital subtraction angiography,DSA)验证确诊为狭窄的33名患者图像。将所得图像由2位高年资放射医师采用盲法阅片,对T1WI 3D-VISTA图像质量进行评分并测量血管狭窄率。利用SPSS 17.0软件进行统计学分析,采用随机单位组方差分析对比T1WI 3D-VISTA、TOF-MRA和DSA三者的测量结果,组间比较采用LSD-t检验;以DSA为金标准对比T1WI 3D-VISTA和TOF-MRA对狭窄的显示情况并计算T1WI 3D-VISTA诊断狭窄的敏感度、特异度等参数。结果:33例病人共计37支MCA检出不同程度狭窄或闭塞;T1WI 3D-VISTA、TOF-MRA和DSA测得的平均狭窄率分别为(63.189±16.050)%、(66.014±15.395)%和(61.351±16.366)%,差异有统计学意义(F=5.443,P=0.006),T1WI 3D-VISTA和TOF-MRA之间差异无统计学意义(P=0.050),DSA和T1WI 3D-VISTA之间差异无统计学意义(P=0.200),DSA和TOF-MRA之间差异有统计学意义(P=0.001)。T1WI 3D-VISTA和DSA诊断MCA狭窄程度的一致性好(?资=0.874,P=0.000),TOF-MRA和DSA诊断MCA狭窄程度的一致性一般(?资=0.593,P=0.000)。结论:T1WI 3D-VISTA技术在诊断MCA狭窄中与DSA有很好的一致性,对MCA狭窄有较好的诊断价值。
Objective:To evaluate the diagnostic value of T1-weighted 3D-volumetric isotropic TSE acquisition(T1WI 3D-VISTA) in middle cerebral artery(MCA) stenosis. Methods:The time of flight magnetic resonance angiography(TOF-MRA) and T1WI 3D-VISTA images of 33 patients who were proved have MCA stenosis by digital subtraction angiography(DSA) from May 2016 to July 2017 were retrospectively analyzed. The images were estimated by two experienced radiologists to score the image quality of T1WI 3D-VISTA and measure the vascular stenosis rate blindly. SPSS 17.0 software was used for statistical analysis. Randomized blocks of variance and LSD-t test were used for analyzing the stenosis rate of T1WI 3D-VISTA,TOF-MRA and DSA. The consistency between T1WI 3D-VISTA and DSA with TOF-MRA and DSA was compared and the sensitivity,specificity and other parameters of T1WI 3D-VISTA was calculated using DSA as the gold standard. Results:Totally 37 arteries were diagnosed with varying degrees of steno-sis or occlusion. The mean stenosis rates of T1WI 3D-VISTA,TOF-MRA and DSA were (63.189±16.050)%,(66.014±15.395)% and (61.351±16.366)% respectively,with statistically significant difference(F=5.443,P=0.006). There was no significant difference between T1WI 3D-VISTA and TOF-MRA(P=0.050),between T1WI 3D-VISTA and DSA(P=0.200),while the stenosis rates of TOF-MRA was significantly higher than that of DSA(P=0.001). A good consistency between T1WI 3D-VISTA and DSA(?资=0.874,P=0.000) while a middle consistency between TOF-MRA and DSA(?资=0.593,P=0.000) was observed. Conclusion:The T1WI 3D-VISTA technique has a good consistency with DSA in diagnosing MCA stenosis,and it has a good diagnostic value for MCA stenosis.
T1加权三维容积各向同性快速自旋回波成像磁共振时间飞跃法血管成像数字减影血管造影大脑中动脉狭窄
T1WI 3D volumetric isotropic TSE acquisitiontime of flight magnetic resonance angiographydigital subtrac-tion angiographymiddle cerebral artery stenosis
0
浏览量
97
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621