The value of ultrasonic shear wave elastography combined with serum midkine, thymidine kinase 1, thyrotropin and thyroglobulin ratio in differential diagnosis of benign and malignant thyroid nodules
Ke Shu-li. The value of ultrasonic shear wave elastography combined with serum midkine, thymidine kinase 1, thyrotropin and thyroglobulin ratio in differential diagnosis of benign and malignant thyroid nodules[J]. Journal of Clinical Ultrasound in Medicine, 2023,25(8).
Ke Shu-li. The value of ultrasonic shear wave elastography combined with serum midkine, thymidine kinase 1, thyrotropin and thyroglobulin ratio in differential diagnosis of benign and malignant thyroid nodules[J]. Journal of Clinical Ultrasound in Medicine, 2023,25(8).DOI:
Objective To investigate the value of ultrasonic shear wave elastography (SWE) combined with serum midkine (MK)
thymidine kinase 1 (TK1)
and the thyrotropin and thyroglobulin (TSH/Tg) ratio in the differential diagnosis of benign and malignant thyroid nodules. Methods The clinical data of 129 patients with thyroid nodules (129 nodules) who were admitted to our hospital from May 2020 to May 2022 were retrospectively selected. According to postoperative pathological results or puncture results
they were divided into benign group with 98 cases and malignant group with 31 cases
all of which underwent ultrasonic SWE examination and serum MK
TK1
TSH and Tg detection. SWE parameters [minimum modulus of elasticity (Emin)
maximum modulus of elasticity (Emax) and average modulus of elasticity (Emean)] in the two groups were compared
and the serum MK
TK1 and TSH/Tg ratio in the two groups were compared. Receiver operating characteristic (ROC) curve was used to analyze the differential diagnosis value of SWE parameters combined with serum MK
TK1 and TSH/Tg ratio for benign and malignant thyroid nodules. Results Compared with the benign group
the Emax
Emin and Emean value and the serum MK
TK1 and TSH/Tg ratio in the malignant group were significantly increased (P<0.05). The area under curve (AUC)
sensitivity and specificity of SWE parameter combined with serum MK
TK1 and TSH/Tg ratio were 0.893
83.92% and 89.82%
respectively. The value of SWE parameter in the differential diagnosis of benign and malignant thyroid nodules was significantly better than that of each indicator alone. Conclusion The SWE parameters Emax
Emin
Emean values and serum MK
TK1
TSH/Tg ratio are significantly different in thyroid nodules of different properties. Their combined detection is of high value in the differential diagnosis of benign and malignant thyroid nodules
which is more advantageous than the single application of various indicators.
关键词
超声剪切波弹性成像中期因子胸苷激酶1促甲状腺素与甲状腺球蛋白比值甲状腺结节良恶性鉴别诊断
Keywords
Ultrasonic shear wave elastographyMidkineThymidine kinase 1Thyrotropin to thyroglobulin ratioThyroid nodulesBenign and malignantDifferential diagnostic