Evaluation of right ventricular contrast echocardiography and transcranial Doppler foaming test on patent foramen ovale in patients with cryptogenic stroke
Evaluation of right ventricular contrast echocardiography and transcranial Doppler foaming test on patent foramen ovale in patients with cryptogenic stroke[J]. Journal of Clinical Ultrasound in Medicine, 2023,25(5).
Evaluation of right ventricular contrast echocardiography and transcranial Doppler foaming test on patent foramen ovale in patients with cryptogenic stroke[J]. Journal of Clinical Ultrasound in Medicine, 2023,25(5).DOI:
Objective: To explore the diagnostic value of contrast-enhanced transesophageal echocardiography (c-TTE) and contrast-enhanced transcranial doppler (c-TCD) in patients with cryptogenic stroke with patent foramen ovale (PFO). Methods: 102 patients with cryptogenic stroke who were diagnosed and treated in our hospital from January 2020 to December 2022 were selected. All patients underwent c-TCD examination and right heart contrast echocardiography. Transesophageal echocardiography (TEE) was used as the diagnostic gold standard. The diagnostic value of right heart contrast echocardiography and c-TCD examination for PFO in patients with cryptogenic stroke was compared. Results: TEE examination confirmed 44 cases of PFO in 102 patients with concealed stroke. The results of c-TCD examination showed that 36 cases were true positive
10 cases were false positive
8 cases were false negative
and 48 cases were true negative; The results of c-TTE showed that there were 42 cases of true positive
3 cases of false positive
2 cases of false negative and 55 cases of true negative. The analysis of the working characteristic (ROC) curve of the subjects showed that the AUC of c-TCD and c-TTE in the diagnosis of PFO in patients with occult stroke were 0.823 and 0.951 respectively
and the sensitivity
specificity and accuracy of c-TCD in the diagnosis of PFO in patients with occult stroke were 81.82%
82.76% and 82.35% respectively
which were significantly lower than 95.45%
94.83% and 95.10% of c-TTE (P<0.05). The semi-quantitative grading of right-to-left shunt by c-TCD was lower than that of c-TTE (P<0.05)
and the detection rate of right-to-left shunt by c-TCD was 30.39%
significantly lower than 58.82% of c-TTE (P<0.05). Conclusion: Compared with c-TCD
c-TTE has higher diagnostic value for cryptogenic stroke patients with PFO
and the degree of semi-quantitative grading of right-to-left shunt is higher and the detection rate is higher for cryptogenic stroke patients with PFO.
关键词
右心声学造影经颅多普勒发泡试验隐源性卒中卵圆孔未闭诊断价值右向左分流
Keywords
Contrast-enhanced transesophageal echocardiographyContrast-enhanced transcranial dopplerFor cryptogenic strokePatent foramen ovaleDiagnostic valueRight to left shunt