SHEN Yeqin, DU Lei, LUO Ji, et al. Value of contrast-enhanced ultrasound and endoscopic ultrasonography in clinical staging of bladder cancer. [J]. Journal of Clinical Ultrasound in Medicine 23(3):232-235(2021)
SHEN Yeqin, DU Lei, LUO Ji, et al. Value of contrast-enhanced ultrasound and endoscopic ultrasonography in clinical staging of bladder cancer. [J]. Journal of Clinical Ultrasound in Medicine 23(3):232-235(2021) DOI: 10.16245/j.cnki.issn1008-6978.2021.03.027.
Value of contrast-enhanced ultrasound and endoscopic ultrasonography in clinical staging of bladder cancer
Objective To compare the application value of preoperative contrast-enhanced ultrasound(CEUS)and endoscopic ultrasonography(EUS)in clinical staging of bladder cancer.Methods A total of 97 patients with bladder cancer who were admitted to our hospital were selected
they were underwent CEUS and EUS before operation and pathological diagnosis after operation.The results of pathological staging were used as gold standard
the coincidence rate of CEUS and EUS in the clinical staging of bladder cancer was compared.Receiver operating characteristic(ROC)curve was drawn to compare the diagnostic value of two methods for bladder cancer staging.Results Among 97 patients with pathological stage
the number of cases in T1
T2
T3
T4 stage were 27
23
30 and 17
respectively.The coincidence rate of CEUS in T1~T4 stages were 77.78%
86.96%
56.67%
88.24%
respectively.And the coincidence rate of EUS were 74.07%
65.22%
36.67%
17.65%
respectively.There were no significant difference of coincidence rates between the two methods in T1
T2
T3 stages.The coincidence rate of CEUS in T4 stage was higher than that of EUS(P<0.05).ROC curve analysis showed that the diagnostic sensitivity
specificity
positive predictive value
negative predictive values of CEUS and EUS were 87.50%
82.35%
58.33%
95.89% and 67.50%
64.71%
29.73%
90.00%
respectively
area under curve were 0.849 and 0.661
the difference were statistically significant(all P<0.05).Conclusion Preoperative CEUS and EUS can be used in the diagnosis of bladder cancer staging
and the diagnostic value of CEUS in patients with T4 stage is higher than that of EUS.
Application of contrast-enhanced ultrasound liver imaging reporting and data system in high-risk patients with alpha-fetoprotein- negative hepatocellular carcinoma
Related Author
郑丽丽
任新平
詹维伟
冯梅晶
李军建
沈业芹
杜磊
罗骥
Related Institution
江苏省无锡市新吴区新瑞医院 上海交通大学医学院附属瑞金医院无锡分院超声科
六安市人民医院超声医学科
Department of Ultrasound,Tongji Hospital,Tongji Medical College ,Huazhong University of Science and Technology
Department of Ultrasound, Southwest Hospital, Third Military Medical University Army Medical University