Platelet count/spleen area ratio and platelet count/spleen diameter ratio in the diagnosis of esophageal varices in patients with hepatitis B cirrhosis
返回论文页
|更新时间:2021-10-08
|
Platelet count/spleen area ratio and platelet count/spleen diameter ratio in the diagnosis of esophageal varices in patients with hepatitis B cirrhosis
Journal of Clinical Ultrasound in MedicineVol. 23, Issue 3, Pages: 229-231(2021)
YANG Xueping, WANG Xuemei, WANG Yue, et al. Platelet count/spleen area ratio and platelet count/spleen diameter ratio in the diagnosis of esophageal varices in patients with hepatitis B cirrhosis. [J]. Journal of Clinical Ultrasound in Medicine 23(3):229-231(2021)
YANG Xueping, WANG Xuemei, WANG Yue, et al. Platelet count/spleen area ratio and platelet count/spleen diameter ratio in the diagnosis of esophageal varices in patients with hepatitis B cirrhosis. [J]. Journal of Clinical Ultrasound in Medicine 23(3):229-231(2021) DOI: 10.16245/j.cnki.issn1008-6978.2021.03.026.
Platelet count/spleen area ratio and platelet count/spleen diameter ratio in the diagnosis of esophageal varices in patients with hepatitis B cirrhosis
Objective To explore the value of platelet count/spleen area ratio(PC/SA)and platelet count/spleen diameter ratio(PC/SD)in the diagnosis of esophageal varices(EV)in patients with hepatitis B cirrhosis.Methods A total of 172 patients with hepatitis B cirrhosis were enrolled
they were divided into EV group(n=121)and no EV group(n=51)according to gastroscope
all of them were examined by gastroscope
blood routine examination and abdominal ultrasonography.Platelet count(PC)
spleen length diameter and spleen thickness diameter were measared.PC/SA and PC/SD were calculated.The value of PC/SA and PC/SD for diagnosis of EV was evaluated by receiver operating characteristic(ROC)curve. The diagnostic efficacy of PC/SA and PC/SD were compared.Results The spleen length diameter and spleen thickness diameter in EV group were significantly larger than those in no EV group
PC
PC/SA and PC/SD in EV group were significantly lower than those in no EV group(all P<0.001).The area under curve(AUC)of PC/SA for diagnosing EV was 0.846(95%CI:0.784~0.897).When the cutoff value was 10.29
the sensitivity
specificity
positive predictive value and negative predictive value were 79.4%
76.5%
88.9% and 60.9%
respectively.The AUC of PC/SD for diagnosis of EV was 0.816(95%CI:0.750~0.871).When the cutoff value was 629.65
the sensitivity
specificity
positive predictive value and negative predictive value were 87.6%
64.7%
85.5% and 68.7%
respectively.The AUC of PC/SA was higher than that of PC/SD(0.846 vs. 0.816
Z=2.954
P=0.003).Conclusion PC/SA and PC/SD can be used to screen EV in patients with hepatitis B cirrhosis.PC/SA
The clinical value of spleen stiffness by acoustic radiation force impulse imaging elastography combined with platelet count for predicting esophageal varices in hepatitis B-related cirrhosisZhang Da-kun, Chen min, Shi Xiao-juan, Wang Rui-fang,
Differential diagnostic value of ultrasound radiomics in parathyroid adenoma and parathyroid hyperplasia
Comparison of two different contrast media in ultrasound guided microwave ablation of small hepatocellular carcinoma
Related Author
张大鹍
陈敏
史晓娟
王瑞芳
杨学平
张瑶
王雪梅
王玥
Related Institution
中国中医科学院西苑医院
解放军总医院第五医学中心
Department of Ultrasound,Beijing Ditan Hospital,Capital Medical University
Department of Ultrasound,the First People Hospital of Neijiang