ZHAO Yang, JIANG Yanna, WANG Xinxian, et al. Evaluation of left ventricular systolic function in patients with hyperuricemia by three-dimensional speckle tracking imaging. [J]. Journal of Clinical Ultrasound in Medicine 23(2):115-118(2021)
ZHAO Yang, JIANG Yanna, WANG Xinxian, et al. Evaluation of left ventricular systolic function in patients with hyperuricemia by three-dimensional speckle tracking imaging. [J]. Journal of Clinical Ultrasound in Medicine 23(2):115-118(2021) DOI: 10.16245/j.cnki.issn1008-6978.2021.02.013.
Evaluation of left ventricular systolic function in patients with hyperuricemia by three-dimensional speckle tracking imaging
Objective To evaluate the left ventricular systolic function in patients with hyperuricemia(HU) by threedimensional speckle tracking imaging(3 D-STI).Methods Twenty-five hyperuricemia patients(HU group) and 30 healthy volunteers(control group) matched by sex and age were selected.Left atrial end systolic diameter(LAD)
left ventricular end diastolic diameter(LVEDd)
and left ventricular end systolic diameter(LVESD) were measured by conventional two-dimensional echocardiography
and left ventricular end diastolic volume(LVEDV)
left ventricular end systolic volume(LVESV) and left ventricular ejection fraction(LVEF) were measured by Simpson biplane method.At the same time
3 D-STI was applied to measure the global longitudinal strain(GLS)
global radial strain(GRS)
global circumferential strain(GCS) and global area strain(GAS) of the left ventricle
and carry on the correlation analysis with blood uric acid value.The ROC curve was drawn to analyze the diagnostic efficacy of left ventricular systolic function damage predicted by 3 D-STI parameters in patients with HU.Results Compared with the control group
LAD
LVEDD
LVESD
LVEDV
LVESV and LVEF in HU group had no significant difference.The left ventricular GLS
GCS and GAS in HU group were reduced significantly
and the difference were statistically significant(all P<0.05).Correlation analysis showed that blood uric acid value was negatively correlated with GLS and GCS(r=-0.571
-0.463
both P<0.05).ROC curve showed that among the 3 D-STI parameters
when the cut-off value of GLS was20.35%
the area under the curve of GLS was 0.919
the sensitivity was 95%
the specificity was 66%
and Youden index was0.61.Conclusion 3 D-STI can evaluate the changes of left ventricular systolic function in patients with HU in early stage.
Evaluation of left ventricular global systolic function in patients with type 2 diabetes mellitus complicated with hyperuricemia by three-dimensional speckle tracking imaging
Related Author
ZHAO Yang
WANG Xinxian
XU Sheng
JIANG Yanna
王莉
王晶晶
孙丽娟
刘艳君
Related Institution
Department of Ultrasound,the First Affiliated Hospital of China Medical University
Department of ultrasound,Beijing Obstetrics and Gynecology Hospital,Capital Medical University