WANG Xiangqian, XU Huaning, CAI Ting, et al. Establishment of predictive models of contrast-enhanced ultrasound in the evaluation of BI-RADS 4 category breast lesions. [J]. Journal of Clinical Ultrasound in Medicine 23(2):110-114(2021)
WANG Xiangqian, XU Huaning, CAI Ting, et al. Establishment of predictive models of contrast-enhanced ultrasound in the evaluation of BI-RADS 4 category breast lesions. [J]. Journal of Clinical Ultrasound in Medicine 23(2):110-114(2021) DOI: 10.16245/j.cnki.issn1008-6978.2021.02.012.
Establishment of predictive models of contrast-enhanced ultrasound in the evaluation of BI-RADS 4 category breast lesions
Objective To analyze the features of contrast-enhanced ultrasound(CEUS) of benign and malignant breast lesions
construct a predictive model
and to explore the value of this model for risk assessment of breast imaging report and data system(BI-RADS) 4 category of lesions.Methods A total of 174 patients with a total of 180 lesions(BI-RADS 4 category)who underwent breast ultrasound examination in our hospital were selected.All patients obtained the final pathological results through surgery.The cases were divided into model construction group(91 cases with 94 lesions) and model verification group(83 cases with 86 lesions).Single-factor and multi-factor Logistic regression analysis was performed on the characteristics of the CEUS enhancement mode of the model building group to construct a predictive model and draw the ROC curve.The diagnostic efficacy of the predictive model for benign and malignant breast lesions was calculated
and the consistency of the blind reading results was analyzed by ultrasound doctor with different experience.Results The characteristic risk factors of Logistic regression analysis were "crab foot" sign or vascular distortion sign
enhanced uniformity and enhanced focal area(OR=11.308
5.980
3.377
all P
<
0.01).The Logistic regression equation(the predictive model):y=-4.239+2.425 x
8
+1.788 x
3
+1.217 x
5
(x
8
: "crab foot" sign or vascular distortion sign
x
3
:enhanced uniformity
x
5
:enhanced focal area).The area under ROC curve of the CEUS predictive model in distinguishing benign and malignant breast lesions was 0.909
the sensitivity
specificity
accuracy
positive predictive value and negative predictive value of the CEUS predictive model were 95.83%
81.58%
89.53%
86.79% and 93.94%
respectively.The Kappa value of the blind reading result consistency test between the different ultrasound doctor was 0.683.Conclusion Breast CEUS prediction model has a high risk assessment value for BI-RADS 4 category of breast lesions
and different ultrasound doctor use this prediction model to diagnose benign and malignant breast lesions has high consistency.
关键词
超声检查造影剂乳腺肿瘤良恶性Logistic模型
Keywords
UltrasonographyContrast agentBreast tumorbenign and malignantLogistic models
Clinical diagnostic value of qualitative and quantitative parameters of contrastenhanced ultrasonography in benign and malignant breast nodules
Application of contrast-enhanced ultrasound liver imaging reporting and data system in high-risk patients with alpha-fetoprotein- negative hepatocellular carcinoma
Related Author
SUN Min
HU Xiaodan
YANG Zhaohui
LIU Hongmei
YU Ling
Xu Qing
XIAO Rong
郑丽丽
Related Institution
Department of Function,the Hospital of Chengdu Office of People’s Government of Tibetan Autonomous Region
江苏省无锡市新吴区新瑞医院 上海交通大学医学院附属瑞金医院无锡分院超声科
Department of Ultrasound,Tongji Hospital,Tongji Medical College ,Huazhong University of Science and Technology
Department of Ultrasound, Southwest Hospital, Third Military Medical University Army Medical University