Value of shear wave elastography combined with BI-RADS classification in the differential diagnosis of maximum diameter≤2 cm breast cancer
Objective To explore the value of shear wave elastography(SWE)combined with breast imaging reporting and data system(BI-RADS) classification in the differential diagnosis of breast cancer with a maximum diameter ≤2 cm(hereinafter referred to as small breast cancer).Methods A total of 177 small breast lesions(maximum diameter ≤2 cm)were selected from 171 patients with breast lesions confirmed by pathology
among which 155 were benign and 22 were malignant.Preoperative BI-RADS classification and SWE were performed to obtain maximum elasticity value(Emax)
average elasticity value(Emean)
minimum elasticity value(Emin)and standard deviation(Esd)
the differences between benign and malignant lesions were compared.The receiver operating characteristic(ROC)curve was drawn to determine the diagnostic critical value of Emax
and the BI-RADS classification was adjusted according to the Emax of category 4 a lesions. The diagnostic efficacy of SWE and BI-RADS classification alone and in combination for BI-RADS 4 a lesions was compared.Results Among the 177 lesions
BI-RADS classification showed 57 lesions were category 3
94 lesions were category 4 a
13 lesions were category 4 b
8 lesions were category 4 c
and 5 lesions were category 5. Emax
Emean
Emin and Esd were significantly higher in malignant compared with benign lesions(all P<0.05).By using cutoff of Emax 87.5 Kpa for downgrading BI-RADS category 4 a lesions to category 3
71 category 4 a lesions were downgraded and 5 cancers were missed.The sensitivity
specificity
accuracy and the area under the ROC curve of Emax combined with BI-RADS in the diagnosis of small breast cancer were 77.3%
82.6%
79.1% and 0.861(95%CI:0.801~0.909)
there were statistically significant differences compared with those of BI-RADS classification alone(all P<0.05).Conclusion Compared with the BI-RADS classification alone
the combined application of SWE can improve the specificity and accuracy in the diagnosis of small breast cancer
and reduce the unnecessary puncture and surgery for 4 a lesions in the clinical diagnosis and treatment
with good application value.
关键词
剪切波弹性成像BI-RADS分类乳腺病灶良恶性
Keywords
Shear wave elastographyBI-RADS classificationBreast lesionsbenign and malignant
The application value of shear wave elastography in evaluating the treatment effect of testicular epididymitis caused by testicular appendage torsion in children
Conventional ultrasound combined with shear wave elastography to distinguish pleomorphic adenoma from Warthin tumor of parotid: comparative with MRI
Application of transperineal shear wave elastography combined with anterior chamber structure parameters in POP screening for puerperaeundergoing natural delivery
Related Author
周玮珺
杨敏
刘勇
徐平
吴兰英
王颖
肖榕
冷晨蕾
Related Institution
安徽医科大学第一附属医院
南京鼓楼医院
Department of ultrasound,Beijing Shijitan Hospital,Capital Medical University