Clinical value of lung ultrasound score in predicting weaning success in patients with severe respiratory support
ObjectiveTo explore the value of lung ultrasound score in predicting weaning success in patients withsevere respiratory support.MethodsA total of 86 patients with severe respiratory support were selected
and they were dividedinto successful weaning group with 64 cases and weaning failure group with 22 cases according to the results of weaning. Thegeneral information
lung ultrasound score
oxygen partial pressure(Pa O2)
oxygenation index(Pa O2/Fi O2)
carbon dioxide partialpressure(Pa CO2)and p H of arterial blood(p H)in two groups before weaning were compared. The factors influencing theoutcome of weaning were analyzed by Logistic regression
and the correlation between lung ultrasound scores and arterial bloodgas analysis indexes were analyzed. The value of lung ultrasound score in predicting the weaning success was analyzed byreceiver operating characteristic(ROC)curve. The success rate of weaning was analyzed by histogram.ResultsThe negativefluid balance
diaphragm mobility
Pa O2
Pa O2/Fi O2 in the successful weaning group before weaning were higher than those in theweaning failure group
and lung ultrasound scores
heart rate and Pa CO2 were lower than those in the weaning failure group
andthe differences were statistically significant(all P<0.05). Logistic regression analysis showed that the negative fluid balance
heart rate
lung ultrasound score
Pa O2
Pa O2/Fi O2
and Pa CO2 before weaning were all related to the outcome of weaning(allP<0.05).The lung ultrasound score was positively correlated with Pa CO2(r=0.677
P<0.05)
and negatively correlated with Pa O2
Pa O2/Fi O2(r=-0.850
-0.634
both P<0.05). When the cut-off value >19.47 point
the AUC of lung ultrasound score inpredicting weaning sucess in patients with severe respiratory support was 0.784
the sensitivity was 54.55%
and the specificitywas 95.31%.ConclusionThe lung ultrasound score has a certain value in predicting the weaning success in patients withsevere respiratory support.
关键词
超声检查肺部肺通气面积重症呼吸支持撤机结局动脉血气分析
Keywords
UltrasonographylungLung ventilation areaSevere respiratory supportWeaning outcomeArterial blood gas analysis