NI Enzhen, ZHANG Guoliang, ZHANG Jin, et al. Correlation between contrast-enhanced ultrasound quantitative parameters and papillary thyroid carcinoma with extrathyroidal invasion. [J]. Journal of Clinical Ultrasound in Medicine 22(11):812-815(2020)
NI Enzhen, ZHANG Guoliang, ZHANG Jin, et al. Correlation between contrast-enhanced ultrasound quantitative parameters and papillary thyroid carcinoma with extrathyroidal invasion. [J]. Journal of Clinical Ultrasound in Medicine 22(11):812-815(2020) DOI: 10.16245/j.cnki.issn1008-6978.2020.11.004.
Correlation between contrast-enhanced ultrasound quantitative parameters and papillary thyroid carcinoma with extrathyroidal invasion
ObjectiveTo investigate the correlation between contrast-enhanced ultrasound(CEUS) quantitativeparameters and papillary thyroid carcinoma(PTC)with extrathyroidal extension(ETE).MethodsRetrospective analysis of thepathological diagnosis in 112 patients with PTC(157 nodules)were performed
including 60 lesions with extrathyroidal extension(ETE group)and 97 lesions without extrathyroidal extension(no ETE group). The size
internal echo
size of the edge
blood flowsignal
ration of anteroposterior diameter to transverse diameter
CEUS enhancement pattern and intensity of the nodules betweentwo groups were compared. Then Logistic regression analysis was used to analyze risk factors for screening of PTC with ETE.ROCwas drawn to analyze the time from peak to one half(TPH)
the wash in slope(WIS)and tumor maximum size in the diagnosis ofPTC with ETE. Taken maximum Youden index as cutoff value
the sensitivity
specificity of diagnosis of PTC with ETE weremeasured.ResultsTumor maximum size and the quantitative parameters of CEUS(WIS
RT
TTP
TPH)were significantlydifferent between the ETE group and no ETE group(all P<0.05). Multivariate Logistic regression analysis showed that tumormaximum size
TPH and WIS were independent risk factors in diagnosing PTC with ETE(OR=4.135
0.907
16.721
all P<0.05).Among the quantitative analysis parameters
TPH had the greatest value in diagnosing PTC with ETE. When cutoff value was60.96
the sensitivity and specificity were 88.3% and 60.8%
and area under the ROC curve was 0.805.ConclusionTumormaximum size
Application of contrast-enhanced ultrasound liver imaging reporting and data system in high-risk patients with alpha-fetoprotein- negative hepatocellular carcinoma
CEUS 5-point method and CEUS predictive models assessment of different sizes BI-RADS 4 of breast lesions comparative research
Related Author
郑丽丽
任新平
詹维伟
冯梅晶
李军建
黄哲
周萍萍
吴晓贝
Related Institution
江苏省无锡市新吴区新瑞医院 上海交通大学医学院附属瑞金医院无锡分院超声科
Department of Ultrasound,Tongji Hospital,Tongji Medical College ,Huazhong University of Science and Technology
Department of Ultrasound, Southwest Hospital, Third Military Medical University Army Medical University
Shanghai General Hospital
the Second Affiliated Hospital of Hainan Medical University