Value of two-dimensional ultrasound,elastography and contrast-enhanced ultrasound in the diagnosis of Hashimoto’s thyroiditis with benign and malignant thyroid nodules
返回论文页
|更新时间:2023-10-09
|
Value of two-dimensional ultrasound,elastography and contrast-enhanced ultrasound in the diagnosis of Hashimoto’s thyroiditis with benign and malignant thyroid nodules
Journal of Clinical Ultrasound in MedicineVol. 22, Issue 10, Pages: 751-754(2020)
LUO Xue, YANG Xiuqiong, ZHANG Yulin, et al. Value of two-dimensional ultrasound,elastography and contrast-enhanced ultrasound in the diagnosis of Hashimoto’s thyroiditis with benign and malignant thyroid nodules. [J]. Journal of Clinical Ultrasound in Medicine 22(10):751-754(2020)
LUO Xue, YANG Xiuqiong, ZHANG Yulin, et al. Value of two-dimensional ultrasound,elastography and contrast-enhanced ultrasound in the diagnosis of Hashimoto’s thyroiditis with benign and malignant thyroid nodules. [J]. Journal of Clinical Ultrasound in Medicine 22(10):751-754(2020) DOI: 10.16245/j.cnki.issn1008-6978.2020.10.008.
Value of two-dimensional ultrasound,elastography and contrast-enhanced ultrasound in the diagnosis of Hashimoto’s thyroiditis with benign and malignant thyroid nodules
Objective To evaluate the diagnostic value of two-dimensional ultrasound
elastography and contrast-enhanced ultrasound and their combinations in Hashimoto’s thyroiditis with benign and malignant nodules.Methods Two-dimensional ultrasound
elastography and contrast-enhanced ultrasound were performed on 54 nodules in 44 patients with Hashimoto’s thyroiditis respectively. The ultrasound diagnosis results were compared with the pathological results. The diagnostic efficiencies of two-dimensional ultrasound
elastography and ultrasound and their combinations were calculated in Hashimoto’s thyroiditis with benign and malignant nodules.Results Taken TI-RADS 4 and 5 as the diagnostic criteria for malignant nodules the diagnostic sensitivity
specificity and accuracy of two-dimensional ultrasound were 50.0%
82.5%
and 74.0%
respectively. Taken Young’s modulus value of nodules measured by shear wave elastography ≥46.1 kPa as the prediction index for malignant nodules
the diagnostic sensitivity
specificity and accuracy of elastography were 57.1%
85.0% and 77.7%
respectively. Taken low heterogeneity enhancement as the diagnostic criteria for malignant nodules
and the diagnostic sensitivity
specificity
and accuracy of contrast-enhanced ultrasound were 64.3%
80.0% and 75.9%
respectively. The diagnostic sensitivity
specificity
and accuracy of the combination of three methods were 85.7%
95.0% and 92.5%
respectively.The accuracy of combinations was higher than that of the single method
and the differences were statistically significant(all P<0.05).Conclusion The combination of different ultrasound methods(two-dimensional ultrasound
elastography
contrast-enhanced ultrasound)is more valuable than single ultrasound method in the diagnosis of Hashimoto’s thyroiditis with benign and malignant nodules
which is worthy of further promotion and application.
关键词
超声检查桥本氏甲状腺炎甲状腺结节良恶性
Keywords
UltrasonographyHashimoto’s thyroiditisThyroid nodulesbenign and malignant