Diagnostic value of contrast-enhanced ultrasound guiding fine-needle aspiration cytology for lateral cervical lymph nodes metastasis in papillary thyroid carcinoma
返回论文页
|更新时间:2023-10-09
|
Diagnostic value of contrast-enhanced ultrasound guiding fine-needle aspiration cytology for lateral cervical lymph nodes metastasis in papillary thyroid carcinoma
Journal of Clinical Ultrasound in MedicineVol. 22, Issue 10, Pages: 737-741(2020)
PAN Dai, XU Yuanbing, MA Fen, et al. Diagnostic value of contrast-enhanced ultrasound guiding fine-needle aspiration cytology for lateral cervical lymph nodes metastasis in papillary thyroid carcinoma. [J]. Journal of Clinical Ultrasound in Medicine 22(10):737-741(2020)
PAN Dai, XU Yuanbing, MA Fen, et al. Diagnostic value of contrast-enhanced ultrasound guiding fine-needle aspiration cytology for lateral cervical lymph nodes metastasis in papillary thyroid carcinoma. [J]. Journal of Clinical Ultrasound in Medicine 22(10):737-741(2020) DOI: 10.16245/j.cnki.issn1008-6978.2020.10.005.
Diagnostic value of contrast-enhanced ultrasound guiding fine-needle aspiration cytology for lateral cervical lymph nodes metastasis in papillary thyroid carcinoma
Objective To explore the value of contrast-enhanced ultrasound guide fine-needle aspiration cytology(CEUS-FNAC)in the diagnosis of lateral cervical lymph nodes(LCLNs)metastasis in papillary thyroid carcinoma(PTC).Methods One hundred and twenty-eight cases of PTC patients who underwent preoperative LCLNS fine-needle aspiration cytology and subsequently surgical treatment were selected. All of them were randomly divided into control group and experimental group with 64 cases each. Conventional ultrasound guide fine-needle aspiration cytology(US-FNAC)was performed on 113 suspicious LCLNs in control group
and CEUS-FNAC was performed on 118 suspicious LCLNs in experimental group. Taken pathological results as the golden standard
and the sensitivity
specificity and accuracy of US-FNAC and CEUS-FNAC in the diagnosis of LCLNs were calculated and compared. The diagnosis value of different sizes(≤10 mm or >10 mm)of LCLNs by US-FNAC and CEUS-FNAC were further analyzed.Results The sensitivity
specificity and accuracy of US-FNAC in the diagnosis of LCLNs metastasis in control group were 72.3%
79.2% and 75.2%
respectively
and of CEUS-FNAC in experimental group were 90.2%
93.5% and 91.5%
respectively. The differences between the two methods were statistically significant(both P<0.05).When the maximum diameter of LCLNs ≤10 mm
the sensitivity and accuracy of CEUS-FNAC in the diagnosis of metastatic lymph node were higher than those of US-FNAC
and the difference were statistically significant(both P<0.05). When maximum diameter of LCLNs >10 mm
there were no significant differences in the sensitivity
specificity and accuracy between CEUS-FNAC and US-FNAC.Conclusion CEUS-FNAC has a higher diagnosis efficiency of LCLNs metastasis in PTC patients
Correlation between contrast-enhanced ultrasound quantitative parameters and microvascular density in papillary thyroid carcinoma
Application of contrast-enhanced ultrasound liver imaging reporting and data system in high-risk patients with alpha-fetoprotein- negative hepatocellular carcinoma
Related Author
CHEN Ping
TANG Chunlin
CHEN Kaixuan
TAN Ying
LIN Yong
WU Feng
CHEN Xiaoqing
GUO Yanli
Related Institution
Department of Ultrasound,the First Affiliated Hospital of Army Medical University
陆军军医大学第一附属医院病理科
江苏省无锡市新吴区新瑞医院 上海交通大学医学院附属瑞金医院无锡分院超声科
Department of Ultrasound,Tongji Hospital,Tongji Medical College ,Huazhong University of Science and Technology
Department of Ultrasound, Southwest Hospital, Third Military Medical University Army Medical University