Value of three-dimensional speckle tracking imaging in diagnosis of severe multi-vessel coronary artery stenosis of non-myocardial infarction in resting state
返回论文页
|更新时间:2021-10-08
|
Value of three-dimensional speckle tracking imaging in diagnosis of severe multi-vessel coronary artery stenosis of non-myocardial infarction in resting state
Journal of Clinical Ultrasound in MedicineVol. 22, Issue 5, Pages: 344-348(2020)
LIU Yafei, TAN Yu, ZENG Saiqun, et al. Value of three-dimensional speckle tracking imaging in diagnosis of severe multi-vessel coronary artery stenosis of non-myocardial infarction in resting state. [J]. Journal of Clinical Ultrasound in Medicine 22(5):344-348(2020)
LIU Yafei, TAN Yu, ZENG Saiqun, et al. Value of three-dimensional speckle tracking imaging in diagnosis of severe multi-vessel coronary artery stenosis of non-myocardial infarction in resting state. [J]. Journal of Clinical Ultrasound in Medicine 22(5):344-348(2020) DOI: 10.16245/j.cnki.issn1008-6978.2020.05.008.
Value of three-dimensional speckle tracking imaging in diagnosis of severe multi-vessel coronary artery stenosis of non-myocardial infarction in resting state
Objective To investigate the value of three-dimensional speckle tracking imaging(3 D-STI) in the diagnosis of severe multi-vessel coronary artery stenosis of non-myocardial infarction in resting state.Methods A total of 100 patients with suspected coronary heart disease who underwent coronary angiography were selected as the research objects in our hospital.The patients were divided into severe multi-vessel stenosis group(40 cases)
severe single-vessel stenosis group(30 cases) and control group(30 cases) according to the results of coronary angiography.3 D-STI technology was used to measure the global longitudinal strain(3 D-GLS)
global circumferential strain(3 D-GCS)
global area strain(3 D-GAS) and global radial strain(3 D-GRS) of the left ventricle at rest.The receiver operating characteristic(ROC) curve was used to analyze the value of3 D-STI in the diagnosis of severe multi-vessel coronary artery stenosis.Results The 3 D-GLS
3 D-GCS
3 D-GAS
3 D-GRS of severe multi-vessel stenosis group and severe single-vessel stenosis group were significantly lower than those of control group(all P<0.05).The 3 D-GLS and 3 D-GAS of severe multi-vessel stenosis group were significantly lower than those of severe single-vessel stenosis group(both P<0.05).The area under the ROC curve predicted by 3 D-GLS for multiple severe stenosis of coronary artery was 0.780
and the sensitivity was 85.1% when the cutoff value was-12%.The area under the ROC curve predicted by 3 D-GAS for multiple severe stenosis of coronary artery was 0.770
and the specificity was 80.2%
when the cutoff value was-21%.When 3 D-GLS was used in parallel with any of the indicators of 3 D-GCS
3 D-GAS and 3 D-GRS
the sensitivity of diagnosis of severe multi-vessel coronary artery stenosis was higher than that of single indicator.Conclusion 3 D-STI has certain diagnostic value for severe multi-vessel coronary artery stenosis of non-myocardial infarction at rest
3 D-GLS and 3 DGAS can be used as more effective diagnostic indicators for severe multi-vessel coronary artery stenosis.
Evaluation of left ventricular function in patients with aortic stenosis with different wall thickness by three-dimensional speckle tracking imaging
Evaluation of left ventricular systolic function in hemodialysis patients with valve calcification by three-dimensional speckle tracking imaging
Value of myocardial longitudinal strain and peak strain dispersion in the assessment of left ventricular systolic function in patients with atrial fibrillation and normal left ventricular ejection fraction
Related Author
JIANG Yanna
ZHAO Yang
XU Sheng
JIANG Yanna
ZHAO Yang
XU Sheng
ZHOU Jinling
WANG Feng
Related Institution
Department of Ultrasound,Liaoning JinqiuHospital
Department of Cardiac Ultrasound,the Second Hospital of Hebei Medical University
Medical imaging Department,Fujian Health College Affiliated to Fujian Provincial Organs Hospital