Vascular Reactivity of Black Plaster Based on the Theory of “Open-Close in the Interstices” in Knee Osteoarthritis Model Rabbits with Cold Blood Coagulation and Blood Stasis Syndrome
返回论文页
|更新时间:2022-10-08
|
Vascular Reactivity of Black Plaster Based on the Theory of “Open-Close in the Interstices” in Knee Osteoarthritis Model Rabbits with Cold Blood Coagulation and Blood Stasis Syndrome
WANG Jiajing, ZHU Ting, LIU Ziheng, et al. Vascular Reactivity of Black Plaster Based on the Theory of “Open-Close in the Interstices” in Knee Osteoarthritis Model Rabbits with Cold Blood Coagulation and Blood Stasis Syndrome. [J]. 22(4):401-406(2022)
DOI:
WANG Jiajing, ZHU Ting, LIU Ziheng, et al. Vascular Reactivity of Black Plaster Based on the Theory of “Open-Close in the Interstices” in Knee Osteoarthritis Model Rabbits with Cold Blood Coagulation and Blood Stasis Syndrome. [J]. 22(4):401-406(2022) DOI: 10.14009/j.issn.1672-2124.2022.04.004.
Vascular Reactivity of Black Plaster Based on the Theory of “Open-Close in the Interstices” in Knee Osteoarthritis Model Rabbits with Cold Blood Coagulation and Blood Stasis Syndrome
OBJECTIVE: To evaluate the mechanism of black plaster based on the theory of “open-close in the interstices” through the study of the vascular reactivity of the knee osteoarthritis model rabbits with cold blood coagulation and blood stasis syndrome. METHODS: The rabbit model of knee osteoarthritis with cold coagulation and blood stasis syndrome was prepared by combining cold stimulation with drug induction. Vascular effects of the periprosthetic arterial network(lower femoral artery
lateral superior genicular artery and inferior lateral genicular artery) in rabbits were closely observed by using color Doppler ultrasound techniques and blood flow indicators. Effects of Goupi plaster(manufacturer 1
manufacturer 2 and manufacturer 3 group) and black plaster matrix(matrix group) on the diameter
blood flow velocity and hemorheological indicators of the perigenicular artery network were investigated from 0 d to 15 d. RESULTS: After 15 d of treatment
the vascular diameter of the the lower femoral artery
the lateral superior genicular artery and inferior lateral genicular artery of the rabbits in the manufacturer 1
the manufacturer 2 and the manufacturer 3 groups and the matrix group increased
and the blood flow velocity increased
the whole blood viscosity and erythrocyte aggregation indicators showed the decreasing trend
and erythrocyte deformability indicators showed the increasing trend. CONCLUSIONS: Both the black plaster matrix and the Goupi plaster have the effects of inducing vascular effects of perigenicular artery network
suggesting that the black plaster matrix also plays a key role in promoting the “open-close in the interstices”.
关键词
黑膏药狗皮膏腠理开阖寒凝血瘀证膝骨关节炎家兔模型血管反应性
Keywords
Black plasterGoupi plasterOpen-close in the intersticesKnee osteoarthritis model rabbits with cold blood coagulation and blood stasis syndromeVascular reactivity