HUANG Xiao-ling1, WANG Zhi-gang2. Performance of contrast-enhanced ultrasonography in renal artery stenosis. [J]. Journal of Chongqing Medical University 36(5):599-601(2011)
HUANG Xiao-ling1, WANG Zhi-gang2. Performance of contrast-enhanced ultrasonography in renal artery stenosis. [J]. Journal of Chongqing Medical University 36(5):599-601(2011) DOI: 10.13406/j.cnki.cyxb.2011.05.008.
Performance of contrast-enhanced ultrasonography in renal artery stenosis
TTP);③峰值强度与基础强度差值(Difference between peak and base intensity
PBD);④曲线上升斜率β。结果:当狭窄
>
50%时
除Ⅱ组肾实质TTP与正常对照组相比差异无统计学意义外(P
>
0.05)
其余各组兔肾实质各项指标与正常对照组相比差异均有统计学意义(P
<
0.05)
表现为AT、TTP延长
PBD降低、β减小
但Ⅱ组与Ⅰ组相比TTP及β的改变无统计学意义(P
>
0.05)。结论:当肾动脉狭窄
>
50%时
与正常对照组相比
肾实质灰阶超声造影各指标中
除Ⅱ组的TTP改变不明显外
其余各组兔各项指标均有明显改变
差异有统计学意义。
Abstract
Objective:To study the performance of contrast-enhanced ultrasonography in renal artery stenosis.Methods:Animal models of renal artery stenosis were established by operation in the left kidney of New Zealand rabbits
and divided into four groups according to the degrees of renal artery stenosis based on CTA.The degrees of stenosis were <50%
50%~69%
70%~99% and 100% in GroupⅠ
GroupⅡ
GroupⅢ and GroupⅣ
respectively.Contrast-enhanced ultrasonography was performed in all rabbits.The AT
TTP
PBS and β on the time-intensity curves of left kidneys of the four groups were compared with those of the control group.Results:All the parameters of renal cortex and medulla in the four groups
except TTP of GroupⅡ
were statistically different from those of the control group when stenosis was more than 50%(P<0.05).However
the TTPs of GroupⅡ and GroupⅠ
and the βs of GroupⅢ and GroupⅡ had no significant differences.Conclusion:All the parameters of renal cortex and medulla in the four groups
except TTP in groupⅡ
are statistically different from those of the control group when renal artery stenosis is more than 50%.