COMPARISON OF PAGE AND ELISA METHODS IN DETECTION OF HUMAN ROTAVIRUS. [J]. Journal of Chongqing Medical University (4):275-277(1993) DOI: 10.13406/j.cnki.cyxb.1993.04.008.
COMPARISON OF PAGE AND ELISA METHODS IN DETECTION OF HUMAN ROTAVIRUS
Human Rotavirus( HR V) was detected in 182 stool samples from the patients suspected of suffering from virus diarrhea PAGE and ELISA methods -were applied and compared. The correspondence rate of the two methods was 81.87%. The sensitivities for PAGE and ELISA methods were 98.33% and 95%
the specificities were 100% and 92.5%
reproducibilities
99.0% and 94.0% respectively Since ELISA is a simple
and rapid procedure
it can be widely used in small Laborato-
关键词
人轮状病毒聚丙烯酰胺凝胶电泳酶联免疫吸附试验
Keywords
Human RotavirusPolyacrylamide gel electrophoresisEnzyme linked immunosorbent assay.