CAI Jin-kui,XU Hai-jia,LI Wei-kang,et al.Effect of N-butyl cyanoacrylate adhesive in preventing bone cement leakage during percutaneous kyphoplasty[J].JOURNAL OF REGIONAL ANATOMY AND OPERATIVE SURGERY,2023,32(10):876-881.
CAI Jin-kui,XU Hai-jia,LI Wei-kang,et al.Effect of N-butyl cyanoacrylate adhesive in preventing bone cement leakage during percutaneous kyphoplasty[J].JOURNAL OF REGIONAL ANATOMY AND OPERATIVE SURGERY,2023,32(10):876-881. DOI: 10.11659/jjssx.03E023070.
Effect of N-butyl cyanoacrylate adhesive in preventing bone cement leakage during percutaneous kyphoplasty
To explore the effect of N-butyl cyanoacrylate (NBCA) adhesive in preventing bone cement leakage during percutaneous kyphoplasty (PKP).
Methods
2
A total of 80 isolated porcine thoracolumbar vertebrae were selected to make the osteopolitic vertebral compression fracture model by decalcification and mechanical machine compression,and then divided into the conventional PKP group and the glue group according to random number table method, with 40 pieces in each group. Each group was further divided into the high-dose group and the low-dose group according to different injection doses of bone cement, with 20 pieces in each subgroup.The conventional PKP group performed PKP using traditional surgical methods,and the glue group was pretreated with NBCA pretreatment to close the intravertebral fissures with a self-designed vertebral fracture spraying tool before the cement injection,and then injected with bone cement.The distribution pattern of bone cement in vertebral body, the leakage rate of bone cement and the number of bone cement leakage in vertebral body were counted.
Results
2
There was no significant difference in bone mineral density of the glue group and the conventional PKP group after decalcification between or within the high-dose group and the low-dose group (
P
>
0.05). The diffusion effect of high-dose cement injection was better than that of low-dose cement injection in the glue group and the conventional PKP group (
P
>
0.05)
but there was no statistically significant difference in the diffusion effect between the groups (
P
<
0.05).The leakage rate of bone cement in the low-dose glue group was lower than that in the low-dose conventional PKP group (
P
<
0.05)
and the leakage rate of bone cement in the high-dose glue group was lower than that in the high-dose conventional PKP group (
P
<
0.05).
Conclusion
2
The pretreatment of vertebra with NBCA adhesive does not affect the diffusion distribution of bone cement in vertebra,which can effectively reduce the leakage rate of bone cement in PKP operation,and the diffusion effect of high-dose bone cement is better, but the leakage risk is also high.
Cheng X,Zhao K,Zha X,et al.Opportunistic screening using low-dose CT and the prevalence of osteoporosis in China:a nationwide,multicenter study[J].J Bone Miner Res,2021,36(3):427-435.doi:10.1002/jbmr.4187http://dx.doi.org/10.1002/jbmr.4187.
Zhan Y,Jiang J,Liao H,et al.Risk factors for cement leakage after vertebroplasty or kyphoplasty:a meta-analysis of published evidence[J].World Neurosurg,2017,101:633-642.doi:10.1016/j.wneu. 2017.01.124http://dx.doi.org/10.1016/j.wneu.2017.01.124.
Noguchi T,Yamashita K,Kamei R,et al.Current status and challenges of percutaneous vertebroplasty (PVP)[J].Jpn J Radiol,2023,41(1):1-13.doi:10.1007/s11604-022-01322-whttp://dx.doi.org/10.1007/s11604-022-01322-w.
Schleicher P,Wengert A,Neuhoff J,et al.Cement augmentation in spinal surgery[J].Unfallchirurgie (Heidelb),2022,125(6):460-466.doi:10.1007/s00113-022-01188-7http://dx.doi.org/10.1007/s00113-022-01188-7.
Lv N,Feng X,Liu H,et al.Study on the influence of balloon dilation mode on the intravertebral cleft of osteoporotic fracture[J].BMC Surg,2022,22(1):351-356.doi:10.1186/s12893-022-01750-5http://dx.doi.org/10.1186/s12893-022-01750-5.
Vizzuso A,Barbieri S,Petrella E,et al.Prostatic artery embolization using n-butyl cyanoacrylate glue in patients with indwelling catheter[J].Cardiovasc Intervent Radiol,2023,46(2):295-298.doi:10.1007/s00270-022-03315-8http://dx.doi.org/10.1007/s00270-022-03315-8.
Higashino N,Sonomura T,Fukuda K,et al.Feasibility and safety of n-butyl cyanoacrylate-lipiodol-iopamidol as an alternative liquid embolic material[J].Cardiovasc Intervent Radiol,2021,44(3):482-488.doi:10.1007/s00270-020-02681-5http://dx.doi.org/10.1007/s00270-020-02681-5.
Picel AC,Koo SJ,Roberts AC.Transcatheter arterial embolization with n-butyl cyanoacrylate for the treatment of acquired uterine vascular malformations[J].Cardiovasc Intervent Radiol,2016,39(8):1170-1176.doi:10.1007/s00270-016-1328-zhttp://dx.doi.org/10.1007/s00270-016-1328-z.
Martino C,Salzano F,Martino D,et al.A prospective randomized trial of n-butyl-cyanoacrylate + metacryloxysulfolane adhesive versus suture alone for grafting in rhinoplasty:9 year follow-up[J].Ann Otol Rhinol Laryngol,2021,130(5):483-489.doi:10.1177/0003489420 943910http://dx.doi.org/10.1177/0003489420943910.
Galibert P,Deramond H,Rosat P,et al.Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty[J].Neurochirurgie,1987,33(2):166-168.
Sebaaly A,Rizkallah M,Bachour F,et al.Percutaneous cement augmentation for osteoporotic vertebral fractures[J].EFORT Open Rev,2017,2(6):293-299.doi:10.1302/2058-5241.2.160057http://dx.doi.org/10.1302/2058-5241.2.160057.
Sasaki K,Okada T,Yamaguchi M,et al.Major and minor complications of the pancreas after transcatheter arterial embolization using n-butyl-2-cyanoacrylate for acute bleeding from pancreatic arteries[J].Jpn J Radiol,2022,40(3):308-317.doi:10.1007/s11604-021-01203-8http://dx.doi.org/10.1007/s11604-021-01203-8.
Elsebaey MA,Tawfik MA,Ezzat S,et al.Endoscopic injection sclerotherapy versus n-butyl-2 cyanoacrylate injection in the management of actively bleeding esophageal varices:a randomized controlled trial[J].BMC Gastroenterol,2019,19(1):23-29.doi:10.1186/s12876-019-0940-1http://dx.doi.org/10.1186/s12876-019-0940-1.
Powell DK,Baum S.Bronchopleural fistula treated with n-butyl cyanoacrylate glue after ablation[J].J Vasc Interv Radiol,2018,29(12):1692-1693.doi:10.1016/j.jvir.2018.06.008http://dx.doi.org/10.1016/j.jvir.2018.06.008.
Moreno BM,Isaksson B,Nyman R,et al.Portal vein embolization with n-butyl-cyanoacrylate before hepatectomy:a single-center retrospective analysis of 46 consecutive patients[J].Acta Radiol,2021,62(9):1170-1177.doi:10.1177/0284185120953802http://dx.doi.org/10.1177/0284185120953802.
Asan Z,Kilitci A.Use of cyanoacrylate to prevent cerebrospinal fluid fistulas after cranial surgery[J].Br J Neurosurg,2018,32(5):544-547.doi:10.1080/02688697.2018.1494265http://dx.doi.org/10.1080/02688697.2018.1494265.
Sultan A,Mohamed A.Efficacy and safety of using n-butyl cyanoacrylate in cranial fixation following trauma and other pathologies[J].Turk Neurosurg,2018,28(3):416-420.doi:10.5137/1019-5149.JTN.20117-17.1http://dx.doi.org/10.5137/1019-5149.JTN.20117-17.1.