Nursing care of patients undergoing coronary angiography based on coronary computed tomography angiography guidebooks with different CT devices
返回论文页
|更新时间:2023-12-22
|
Nursing care of patients undergoing coronary angiography based on coronary computed tomography angiography guidebooks with different CT devices
Journal of Chongqing Medical UniversityVol. 44, Issue 10, Pages: 1367(2019)
作者机构:
四川大学华西医院放射科,成都,610041
作者简介:
基金信息:
DOI:
CLC:
Published:2019,
扫 描 看 全 文
Li Li, Zhao Lihong, Li Juan, et al. Nursing care of patients undergoing coronary angiography based on coronary computed tomography angiography guidebooks with different CT devices. [J]. Journal of Chongqing Medical University 44(10):1367(2019)
DOI:
Li Li, Zhao Lihong, Li Juan, et al. Nursing care of patients undergoing coronary angiography based on coronary computed tomography angiography guidebooks with different CT devices. [J]. Journal of Chongqing Medical University 44(10):1367(2019)DOI:
Nursing care of patients undergoing coronary angiography based on coronary computed tomography angiography guidebooks with different CT devices
Objective:To investigate the effects of different scanning methods and medication with different computed tomography (CT) devices on subjects and their nursing care during coronary angiography. Methods:Based on the coronary computed tomography angiography(CCTA) guidebooks,subjects were divided into the group A and group B. Group A had scanning scheme a of the comput-ed tomography angiography(CTA) using the 2016 Siemens second-generation dual-source CT device in our hospital and medication in accordance with nurses’ experience;group B had scanning scheme b of coronary CTA using 2017 General Electrical(GE) wide detec-tor CT device in our hospital and medication based on iodine flow rate. The one-time examination success rate,contrast agent ex-travasation,adverse reaction rate,and the satisfaction of the subjects were observed. The difference was considered statistically signifi-cant if P<0.05. Results:Requirements for subjects’ cooperation,subjects’ individual factors,failure rate,rescanning rate and the inci-dence of contrast agent extravasation in the group B were lower than those in the group A;satisfaction degree in the group B was higher than that in the group A;all differences had statistical significance(P<0.05). However,the incidence of adverse reactions in two groups had no statistically significant difference(P>0.05). Conclusion:GE wide detector device combined with the iodine flow rate has low requirement for subjects’ cooperation and high one-time success rate,which can effectively improve the patients’ satisfaction degree and simplify the nursing process, worthy of promotion and application in clinical medical laboratory.