浏览全部资源
扫码关注微信
1.南京医科大学附属儿童医院药学部,南京 210008
2.中国药科大学基础医学与临床药学学院,南京 210009
3.南京医科大学附属儿童医院检验科,南京 210008
硕士研究生。研究方向:临床药学。E-mail:liusimin0330@163.com
药师,硕士。研究方向:儿科精准用药。E-mail:zyynjeryy0526@163.com
收稿:2025-12-29,
修回:2026-03-31,
录用:2026-03-31,
纸质出版:2026-05-15
移动端阅览
刘思敏,储雅旻,胡雅慧,等.人全血中他克莫司浓度测定方法的建立及临床应用 [J].中国药房,2026,37(09):1180-1184.
LIU Simin,CHU Yamin,HU Yahui,et al.Establishment and clinical application of a method for the determination of tacrolimus concentration in human whole blood[J].ZHONGGUO YAOFANG,2026,37(09):1180-1184.
刘思敏,储雅旻,胡雅慧,等.人全血中他克莫司浓度测定方法的建立及临床应用 [J].中国药房,2026,37(09):1180-1184. DOI: 10.6039/j.issn.1001-0408.2026.09.12.
LIU Simin,CHU Yamin,HU Yahui,et al.Establishment and clinical application of a method for the determination of tacrolimus concentration in human whole blood[J].ZHONGGUO YAOFANG,2026,37(09):1180-1184. DOI: 10.6039/j.issn.1001-0408.2026.09.12.
目的
2
建立测定人全血中他克莫司(TAC)浓度的方法,并将其应用于临床。
方法
2
采用甲醇沉淀蛋白的方法处理全血样品。采用液相色谱-串联质谱(LC-MS/MS)法进行测定,以子囊霉素为内标,使用Kinetex F5 100Å色谱柱,以含0.2 mmol/L甲酸的0.1 mmol/L醋酸铵溶液和甲醇为流动相进行梯度洗脱,流速为0.4 mL/min,进样体积为5 μL;采用电喷雾离子源在正离子模式下进行多反应监测(TAC
m
/
z
821.6→768.6,子囊霉素
m
/
z
809.4→756.1)。以2025年9月1-30日于南京医科大学附属儿童医院接受TAC治疗的83名患儿的86例全血样本为研究对象,采用上述方法测定全血中TAC浓度,并通过Spearman相关性分析、Bland-Altman分析、Passing-Bablok回归分析评估上述方法与传统酶放大免疫分析(EMIT)法的相关性和一致性。
结果
2
TAC的线性范围为0.5~100 ng/mL,准确度、精密度、提取回收率、基质效应、稳定性试验的考察结果均符合相关要求。临床应用结果显示,LC-MS/MS法和EMIT法测定的患儿全血中TAC浓度的中位值分别为4.4、4.0 ng/mL,且两种方法具有强相关性(相关系数为0.848 1)与良好的一致性(平均相对偏差为6.5%)。
结论
2
本研究成功建立了测定人全血中TAC浓度的LC-MS/MS法,且该法与EMIT法具有强相关性和良好的一致性,可用于临床治疗药物监测。
OBJECTIVE
2
To develop a method for the determination of tacrolimus (TAC) concentration in human whole blood and to apply it in clinical therapeutic drug monitoring.
METHODS
2
Whole blood samples were processed by protein precipitation with methanol. The determination was performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS), with ascomycin serving as the internal standard. Chromatographic separation was carried out on a Kinetex F5 100Å column with a mobile phase consisting of 0.1 mmol/L ammonium acetate containing 0.2 mmol/L formic acid and methanol. Gradient elution was performed at a flow rate of 0.4 mL/min. The injection volume was 5 μL. Detection was conducted using multiple reaction monitoring (
m
/
z
821.6→768.6 for TAC;
m
/
z
809.4→756.1 for ascomycin) with an electrospray ionization source in positive ion mode. The study focused on 86 whole blood samples collected from 83 pedi
atric patients who received TAC therapy at Children’s Hospital of Nanjing Medical University from September 1 to 30, 2025. The aforementioned method was employed to measure the TAC concentration in the whole blood samples. The correlation and agreement between the aforementioned method and the traditional enzyme multiplied immunoassay technique (EMIT) were evaluated through Spearman correlation analysis, Bland-Altman analysis, and Passing-Bablok regression analysis.
RESULTS
2
The linear range of TAC was 0.5-100 ng/mL; the evaluation results for accuracy, precision, extraction recovery, matrix effect, and stability tests all met the relevant requirements. Clinical application results showed that the median concentration of TAC in pediatric whole blood measured by LC-MS/MS and EMIT methods were 4.4 and 4.0 ng/mL, respectively. Moreover, the two methods exhibited a strong correlation (correlation coefficient of 0.848 1) and good agreement (average relative deviation of 6.5%).
CONCLUSIONS
2
A reliable LC-MS/MS method for the determination of TAC concentration in human whole blood is successfully established. This method demonstrates strong correlation and good agreement with the EMIT method, making it suitable for clinical therapeutic drug monitoring.
THOMSON A W , BONHAM C A , ZEEVI A . Mode of action of tacrolimus (FK506):molecular and cellular mechanisms [J ] . Ther Drug Monit , 1995 , 17 ( 6 ): 584 - 591 .
Improving Global Outcomes (KDIGO) Glomerular Di- seases Work Group . KDIGO 2021 clinical practice guideline for the management of glomerular diseases [J ] . Kidney Int , 2021 , 100 ( 4S ): S1 - S276 .
BRUNET M , VAN GELDER T , ÅSBERG A , et al . Therapeutic drug monitoring of tacrolimus-personalized therapy:second consensus report [J ] . Ther Drug Monit , 2019 , 41 ( 3 ): 261 - 307 .
LEGATT D F , SHALAPAY C E , CHENG S B . The EMIT 2000 tacrolimus assay:an application protocol for the Beckman Synchron LX20 PRO analyzer [J ] . Clin Biochem , 2004 , 37 ( 11 ): 1022 - 1030 .
DUBBELBOER I R , POHANKA A , SAID R , et al . Quantification of tacrolimus and three demethylated metabolites in human whole blood using LC-ESI-MS/MS [J ] . Ther Drug Monit , 2012 , 34 ( 2 ): 134 - 142 .
HIEU T B , DUNG N M , TOAN P Q , et al . Determination of tacrolimus in human whole blood in kidney transplant recipients using a rapid and specific LC-MS/MS method [J ] . Clinical Laboratory Analysis , 2023 , 37 ( 15/16 ): e24958 .
TSZYRSZNIC W , BOROWIEC A , PAWLOWSKA E , et al . Two rapid ultra performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) methods with common sample pretreatment for therapeutic drug monitoring of immunosuppressants compared to immunoassay [J ] . J Chromatogr B Analyt Technol Biomed Life Sci , 2013 , 928 : 9 - 15 .
BOER K , DEUFEL T , SCHMIDT D , et al . Application of the EMIT 2000 tacrolimus assay on the Abbott Architect c8000 high volume clinical chemistry analyzer [J ] . Clin Biochem , 2006 , 39 ( 10 ): 1041 - 1043 .
MOSCATO D , NONNATO A , ADAMO R , et al . Therapeutic monitoring of tacrolimus:aberrant results by an immunoassay with automated pretreatment [J ] . Clin Chim Acta , 2010 , 411 ( 1/2 ): 77 - 80 .
TRIVEDI V , SHAH P A , SHRIVASTAV P S , et al . Optimization of chromatography to overcome matrix effect for reliable estimation of four small molecular drugs from biological fluids using LC-MS/MS [J ] . Biomed Chromatogr , 2020 , 34 ( 3 ): e4777 .
GONG Z S , WU Z H , XU S X , et al . A high-throughput LC-MS/MS method for the quantification of four immunosuppressants drugs in whole blood [J ] . Clin Chim Acta , 2019 , 498 : 21 - 26 .
国家药典委员会 . 中华人民共和国药典:四部 [M ] . 2020年版 . 北京 : 中国医药科技出版社 , 2020 : 466 - 472 .
U.S. Food and Drug Administration . Bioanalytical method validation:guidance for industry [EB/OL ] .[ 2025-07-01 ] . https://www.fda.gov/regulatory-information/search-fda-guidance-documents/bioanalytical-method-validation-gui-dance-industry https://www.fda.gov/regulatory-information/search-fda-guidance-documents/bioanalytical-method-validation-gui-dance-industry .
BUCHWALD A , WINKLER K , EPTING T . Validation of an LC-MS/MS method to determine five immunosuppressants with deuterated internal standards including MPA [J ] . BMC Clin Pharmacol , 2012 , 12 : 2 .
ZHAO Y T , DAI H R , LI Y , et al . Comparison of LC-MS/MS and EMIT methods for the precise determination of blood sirolimus in children with vascular anomalies [J ] . Front Pharmacol , 2022 , 13 : 925018 .
GODFREY A R , JONES L , DAVIES M , et al . Miltefosine:a novel internal standard approach to lysophospholipid quantitation using LC-MS/MS [J ] . Anal Bioanal Chem , 2017 , 409 ( 11 ): 2791 - 2800 .
BODNAR-BRONIARCZYK M , PAWIŃSKI T , KUNICKI P K . Isotope-labeled versus analog internal standard in LC-MS/MS method for tacrolimus determination in human whole blood samples:a compensation of matrix effects [J ] . J Chromatogr B , 2019 , 1104 : 220 - 227 .
BAZIN C , GUINEDOR A , BARAU C , et al . Evaluation of the architect tacrolimus assay in kidney,liver,and heart transplant recipients [J ] . J Pharm Biomed Anal , 2010 , 53 ( 4 ): 997 - 1002 .
0
浏览量
6
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621