浏览全部资源
扫码关注微信
400038 重庆,陆军军医大学(第三军医大学)第一附属医院心血管内科
[舒茂琴,E-mail:shumaoqinswh@sina.com SHU Maoqin, E-mail: shumaoqinswh@sina.com
收稿:2023-06-09,
修回:2023-08-10,
纸质出版:2023-10-30
移动端阅览
柴虹, 舒茂琴, 蒋周芩, 等. 心腔内超声心动图下经导管房颤射频消融术有效性及安全性的回顾性队列研究[J]. 陆军军医大学学报, 2023,45(20):2159-2164.
Hong CHAI, Maoqin SHU, Zhouqin JIANG, et al. Efficacy and safety of intracardiac echocardiography-guided radiofrequency ablation for atrial fibrillation: a retrospective report of 192 cases[J]. Journal of Army Medical University, 2023, 45(20): 2159-2164.
柴虹, 舒茂琴, 蒋周芩, 等. 心腔内超声心动图下经导管房颤射频消融术有效性及安全性的回顾性队列研究[J]. 陆军军医大学学报, 2023,45(20):2159-2164. DOI: 10.16016/j.2097-0927.202306048.
Hong CHAI, Maoqin SHU, Zhouqin JIANG, et al. Efficacy and safety of intracardiac echocardiography-guided radiofrequency ablation for atrial fibrillation: a retrospective report of 192 cases[J]. Journal of Army Medical University, 2023, 45(20): 2159-2164. DOI: 10.16016/j.2097-0927.202306048.
目的
2
探索心腔内超声心动图(intracardiac echocardiography,ICE)指导下经导管房颤射频消融术的有效性及安全性。
方法
2
采用回顾性队列研究设计,收集2019年2月至2021年7月在我科行经导管房颤射频消融术的患者,根据其是否使用ICE,将其分为ICE组(
n
=192)和非ICE组(
n
=167),对比2组的放射暴露时间、放射暴露量、消融总时间、单圈隔离率及并发症等,评估ICE指导下房颤导管消融术的有效性及安全性。
结果
2
ICE组与非ICE组相比,消融总时间明显缩短[(68.35±1.09)min
vs
(74.37±1.69)min,
P
<
0.01
]
,单圈隔离率明显提高(70.83%
vs
53.89%,
P
<
0.01),放射暴露量[(33.86±1.51)mGy
vs
(212.30±21.11)mGy,
P
<
0.01
]
及放射暴露时间[(4.90±0.23)min
vs
(13.51±0.34)min,
P
<
0.01
]
明显减少。2组各发生2例并发症,无统计学差异,ICE组无严重并发症,非ICE组术中并发急性心包压塞1例。ICE组消融早期及晚期复发率较非ICE组无显著差异,但晚期复发率有降低的趋势(3.13%
vs
7.78%,
P
=0.06),2组安全性无显著差异。
结论
2
ICE指导下经导管房颤射频消融术有更高的消融效率、更少的射线暴露;2组安全性无显著差异,ICE组晚期复发率有降低的趋势。
Objective
2
To investigate the efficacy and safety of catheter ablation for atrial fibrillation under the guidance of intracardiac echocardiography (ICE).
Methods
2
A retrospective cohort trial was conducted on all the patients who underwent radiofrequency catheter ablation due to atrial fibrillation in our department from February 2019 to July 2020. They were divided into ICE group (
n
=192) and non-ICE group (
n
=167). The radiation exposure time
radiation exposure amount
total ablation time
single coil isolation rate
and incidence of complications were compared between the 2 groups to evaluate the efficacy and safety of ICE-guided ablation for atrial fibrillation.
Results
2
The ICE group had significantly shorter total ablation time (68.35±1.09
vs
74.37±1.69 min
P
<
0.01)
higher single coil isolation rate (70.83%
vs
53.89%
P
<
0.01)
less radiation exposure amount (33.86±1.51
vs
212.30±21.11 mGy
P
<
0.01) and shorter radiation time (4.90±0.23
vs
13.51±0.34 min
P
<
0.01) when compared with the non-ICE group. No statistical difference was seen in the incidence of complications between the 2 groups. Complications were observed in 2 cases of both groups. There were no serious complication in the ICE group
while 1 case of intraoperative cardiac perforation was in non-ICE group. Though no significant difference was found in the early and late recurrence rates of ablation in the ICE group than the non-ICE group
a decreasing trend in late recurrence rates was observed in both groups (3.13%
vs
7.78%
P
=0.06).
Conclusion
2
ICE-guided catheter ablation of atrial fibrillation has higher ablation efficiency and less radiation exposure. There is no significant difference in safety between the 2 groups
but ICE leads to a decreasing trend in late recurrence rate.
中华医学会心血管病学分会, 中国生物医学工程学会心律分会. 心房颤动诊断和治疗中国指南[J]. 中华心血管病杂志, 2023, 51(6) : 572-618. DOI: 10.3760/cma.j.cn112148-20230416-00221.
Chinese Society of Cardiovascular Diseases of Chinese Medical Association, Heart Rhythm Committee of Chinese Society of Biomedical Engineering. Chinese guidelines on diagnosis and management of atrial fibrillation[J]. Chin J Cardiol, 2023, 51(6): 572-618. DOI: 10.3760/cma.j.cn112148-20230416-00221.
BOERSMA L, ANDRADE J G, BETTS T, et al . Progress in atrial fibrillation ablation during 25 years of Europace journal[J ] . Europace, 2023, 25(9): euad244. DOI: 10.1093/europace/euad244.
BERTAGLIA E, DELLA BELLA P, TONDO C, et al . Image integration increases efficacy of paroxysmal atrial fibrillation catheter ablation: results from the CartoMerge TM Italian Registry[J ] . Europace, 2009, 11(8): 1004-1010. DOI: 10.1093/europace/eup152..
CAPONI D, CORLETO A, SCAGLIONE M, et al . Ablation of atrial fibrillation: does the addition of three-dimensional magnetic resonance imaging of the left atrium to electroanatomic mapping improve the clinical outcome? A randomized comparison of Carto-Merge vs . Carto-XP three-dimensional mapping ablation in patients with paroxysmal and persistent atrial fibrillation[J ] . Europace, 2010, 12(8): 1098-1104. DOI: 10.1093/europace/euq107..
ANDRADE J G, MONIR G, POLLAK S J, et al . Pulmonary vein isolation using "contact force" ablation: the effect on dormant conduction and long-term freedom from recurrent atrial fibrillation—a prospective study[J ] . Heart Rhythm, 2014, 11(11): 1919-1924. DOI: 10.1016/j.hrthm.2014.07.033.
NATALE A, REDDY V Y, MONIR G, et al . Paroxysmal AF catheter ablation with a contact force sensing catheter[J ] . J Am Coll Cardiol, 2014, 64(7): 647-656. DOI: 10.1016/j.jacc.2014.04.072.
ZHONG J Q, LONG D Y, CHU H M, et al . Intracardiac echocardiography Chinese expert consensus[J ] . Front Cardiovasc Med, 2022, 9: 1012731. DOI: 10.3389/fcvm.2022.1012731.
WINKLE R A, MEAD R H, ENGEL G, et al . Very long term outcomes of atrial fibrillation ablation[J ] . Heart Rhythm, 2023, 20(5): 680-688. DOI: 10.1016/j.hrthm.2023.02.002.
SOUSA P A, PUGA L, ADÃO L, et al . Two years after pulmonary vein isolation guided by ablation index—a multicenter study[J ] . J Arrhythmia, 2022, 38(3): 346-352. DOI: 10.1002/joa3.12696.
HUSSEIN A, DAS M, RIVA S, et al . Use of ablation index-guided ablation results in high rates of durable pulmonary vein isolation and freedom from arrhythmia in persistent atrial fibrillation patients[J ] . Circ Arrhythmia Electrophysiol, 2018 Sep; 11(9): e006576. DOI: 10.1161/CIRCEP.118.006576.
CALKINS H, HINDRICKS G, CAPPATO R, et al . 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: executive summary[J ] . J Interv Card Electrophysiol, 2017, 50(1): 1-55. DOI: 10.1007/s10840-017-0277-z.
DAS M, LOVEDAY J J, WYNN G J, et al . Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values[J ] . Europace, 2017, 19(5): 775-783. DOI: 10.1093/europace/euw105.
HUSSEIN A, DAS M, CHATURVEDI V, et al . Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation[J ] . J Cardiovasc Electrophysiol, 2017, 28(9): 1037-1047. DOI: 10.1111/jce.13281.
KLEEMANN T, BRACHMANN J, LEWALTER T, et al . Development of radiation exposure in patients undergoing pulmonary vein isolation in Germany between 2007 and 2014: great potential to minimize radiation dosage[J ] . Clin Res Cardiol, 2016, 105(10): 858-864. DOI: 10.1007/s00392-016-0994-9.
DEBRECENI D, JANOSI K, BOCZ B, et al . Zero fluoroscopy catheter ablation for atrial fibrillation: a systematic review and meta-analysis[J ] . Front Cardiovasc Med, 2023, 10: 1178783. DOI: 10.3389/fcvm.2023.1178783.
ELVIN GUL E, AZIZI Z, ALIPOUR P, et al . Fluoroless catheter ablation of atrial fibrillation: integration of intracardiac echocardiography and cartosound module[J ] . J Atr Fibrillation, 2021, 14(2): 20200477. DOI: 10.4022/jafib.20200477.
LIU X K, PALMER J. Outcomes of 200 consecutive, fluoroless atrial fibrillation ablations using a new technique[J]. Pacing Clinical Electrophis, 2018, 41(11): 1404-1411. DOI: 10.1111/pace.13492.
FRIEDMAN D J, POKORNEY S D, GHANE M A, et al . Predictors of cardiac perforation with catheter ablation of atrial fibrillation[J ] . JACC Clin Electrophysiol, 2020, 6(6): 636-645. DOI: 10.1016/j.jacep.2020.01.011.
BOTTONI N, DONATEO P, ROSSI L, et al . Impact of systematic use of intracardiac ultrasound during transseptal catheterization in the electrophysiology laboratory[J ] . J Cardiovasc Dev Dis, 2023, 10(2): 62. DOI: 10.3390/jcdd10020062.
RADINOVIC A, MAZZONE P, LANDONI G, et al . Different transseptal puncture for different procedures: Optimization of left atrial catheterization guided b y transesophageal echocardiography[J ] . Ann Card Anaesth, 2016, 19(4): 589-593. DOI: 10.4103/0971-9784.191548.
KNECHT S, WRIGHT M, LELLOUCHE N, et al . Impact of a patent foramen ovale on paroxysmal atrial fibrillation ablation[J ] . J Cardiovasc Electrophysiol, 2008, 19(12): 1236-1241. DOI: 10.1111/j.1540-8167.2008.01260.x.
KAUTZNER J, PEICHL P. You get what You inspect, not what You expect: can we make the transseptal puncture safer?[J]. Europace, 2010, 12(10): 1353-1355. DOI: 10.1093/europace/euq358.
DE PONTI R, CAPPATO R, CURNIS A, et al . Trans-septal catheterization in the electrophysiology laboratory[J ] . J Am Coll Cardiol, 2006, 47(5): 1037-1042. DOI: 10.1016/j.jacc.2005.10.046.
ANNA R T S, LIMA G G, SAFFI M L, et al . Atrial fibrillation ablation: impact of intracardiac echocardiography in reducing procedure time and hospitalization[J ] . Arq Bras Cardiol 2023, 120 (5), e20220306. DOI: 10.36660/abc.20220306.
JAN M, ŽIŽEK D, KUHELJ D, et al . Combined use of electro-anatomic mapping system and intracardiac echocardiography to achieve zero-fluoroscop y catheter ablation for treatment of paroxysmal atrial fibrillation: a single centre experience[J ] . Int J Cardiovasc Imaging, 2020, 36(3): 415-422. DOI: 10.1007/s10554-019-01727-1.
KAWAJI T, AIZAWA T, HOJO S, et al . The impact of current strategy using intracardiac echocardiography, lesion index, and minimum substrate ablation on clinical outcomes after catheter ablation procedure for atrial fibrillation[J ] . J Arrhythmia, 2021, 37(5): 1278-1286. DOI: 10.1002/joa3.12611.
REDDY V, SHAH D, KAUTZNER J, et al . The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study[J ] . Heart Rhythm, 2012, 9(11): 1789-1795. DOI: 10.1016/j.hrthm.2012.07.016.
NEUZIL P, REDDY V Y, KAUTZNER J, et al . Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment[J ] . Circ Arrhythmia Electrophysiol, 2013, 6(2): 327-333. DOI: 10.1161/circep.113.000374.
STEINBERGB A, HAMMILL B G, DAUBERT J P, et al . Periprocedural imaging and outcomes after catheter ablation of atrial fibrillation[J ] . Heart, 2014, 100(23): 1871-1877. DOI: 10.1136/heartjnl-2014-306067.
PIMENTEL R C, RAHAI N, MACCIONI S, et al . Differences in outcomes among patients with atrial fibrillation undergoing catheter ablation with versus without intracardiac echocardiography[J ] . Cardiovasc Electrophysiol, 2022, 33(9): 2015-2047. DOI: 10.1111/jce.15599.
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621