浏览全部资源
扫码关注微信
400038 重庆,陆军军医大学(第三军医大学)第一附属医院骨科,全军矫形外科中心
[ 许建中,E-mail:xngkxjz@sina.com XU Jianzhong, E-mail: xngkxjz@sina.com
收稿:2018-04-16,
修回:2018-05-10,
纸质出版:2018-10-15
移动端阅览
汪正东, 代飞, 刘瑶瑶, 等. 可注射骨水泥椎弓根螺钉在骨质疏松症脊柱内固定手术应用中的中长期临床疗效评估[J]. 第三军医大学学报, 2018,40(19):1777-1783.
Zhengdong WANG, Fei DAI, Yaoyao LIU, et al. Bone cement-injectable cannulated pedicle screw augmented with polymethylme-thacrylate in osteoporotic spine: a mid- and long-term clinical efficacy of 128 cases[J]. Journal of Third Military Medical University, 2018, 40(19): 1777-1783.
汪正东, 代飞, 刘瑶瑶, 等. 可注射骨水泥椎弓根螺钉在骨质疏松症脊柱内固定手术应用中的中长期临床疗效评估[J]. 第三军医大学学报, 2018,40(19):1777-1783. DOI: 10.16016/j.1000-5404.201804100.
Zhengdong WANG, Fei DAI, Yaoyao LIU, et al. Bone cement-injectable cannulated pedicle screw augmented with polymethylme-thacrylate in osteoporotic spine: a mid- and long-term clinical efficacy of 128 cases[J]. Journal of Third Military Medical University, 2018, 40(19): 1777-1783. DOI: 10.16016/j.1000-5404.201804100.
目的
2
评价可注射骨水泥椎弓根螺钉(bone cement-injectable cannulated pedicle screw,CICPS)在骨质疏松症(osteoporosis,OP)脊柱手术应用中的中长期安全性及有效性。
方法
2
本科2011年3月至2015年3月收治OP患者128例,均应用CICPS进行脊柱内固定手术。术前进行腰腿痛视觉模拟评分法(Visual Analogue Scale/Score
VAS)评分、Oswestry功能障碍指数问卷表(ODI)评分,行X线、CT、MRI检查进行影像学评估。术后即刻(术后1周内)复查X线片,术后1、3、6、12个月及以后每年定期随访,统计各个随访节点各指标[临床指标:腰痛VAS评分、腿痛VAS评分、ODI评分;影像学指标:椎体高度、椎间隙高度、滑脱角、Taillard指数、螺钉位移情况(钉尖至椎体前缘及上终板的距离,分别记为x
y)、融合率;并发症情况:骨水泥渗漏情况、血管栓塞、肺栓塞
]
,并与术前、术后即刻进行对比分析,采用SPSS 18.0统计软件,对符合正态分布变量的进行配对
t
检验。评估患者临床症状、影像学检查、并发症等情况。
结果
2
病例均获随访,随访时间23~71(42.4±13.4)个月。共使用418枚CICPS,术中及随访过程中共发现27枚螺钉发生骨水泥渗漏(约占6.46%),均未发现任何临床并发症。末次随访腰腿痛VAS评分、ODI指数均明显低于术前(
P
<
0.05),末次随访螺钉位置较术后即刻无明显移位(
P
<
0.05),且均获骨性融合,无一例翻修病例。术后未发生感染及血栓形成。
结论
2
骨水泥强化的CICPS应用于OP脊柱内固定手术安全、有效。
Objectives
2
To evaluate the mid- and long-term safety and efficacy of a novel bone cement-injectable cannulated pedicle screw (CICPS) augmented with polymethylmethacrylate (PMMA) in osteoporotic spinal surgery.
Methods
2
A total of 128 osteoporosis patients who underwent spinal instrumentation with PMMA-augmented CICPS in our department from March 2011 to March 2015 were enrolled in this study. Postoperative Visual Analogue Scale (VAS) and Oswestry Disability Index (ODI) were carried out preoperatively. Postoperative plain radiography and CT scanning were performed immediately after surgery. All the patients were followed up at 1
3
6 and 12 months
and annually thereafter. Their clinical parameters (VAS scores for low back and leg pains and ODI score)
radiological indexes [vertebral height
intervertebral space height
slip angle
Taillard index
fusion rate and screw displacement (distance from screw tip to anterior edge of vertebral body and upper endplate)]
complications (bone cement leakage
vascular embolism and pulmonary embolism) were observed and measured
and the results at pre-operation and immediate post-operation were compared with the aid of SPSS 18.0 statistics.
Results
2
All patients were followed up for a mean time of 42.4±13.4 months (23 to 71 months).A total of 418 PMMA-augmented CICPS were used
but cement extravasations were only found in 27 CICPS (6.46%)
and caused no clinical sequela. The low back and lower limb VAS scores and ODI scores at the final follow-up were significantly lower than those of pre-operation (P < 0.05). No significant screw displacement was found at the final follow-up when compared with immediately after surgery (P < 0.05). All cases got successful bone fusion and no one needed revision. No infection and blood clots occurred after surgery.
Conclusion
2
The PMMA-augmented CICPS is safe and effective for osteoporotic patients who require spinal instrumentation.
LIU D, SHI L, LEI W, et al .Biomechanical comparison of expansive pedicle screw and polymet hylmethacrylate-augmented pedicle screw in osteoporotic synthetic bone in primary implantation: an experimental study[J ] .Clin Spine Surg, 2016, 29(7): E351-357. DOI:10.1097/BSD.0b013e31828bfc85.
SCHMID S L, BACHMANN E, FISCHER M, et al .Pedicle screw augmentation with bone cement enforced Vicryl mesh[J ] .J Orthop Res, 2018, 36(1) : 212-216. DOI:212-216.10.1002/jor.23631.
CHEN L H, TAI C L, LEE D M, et al . Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling[J ] . BMC Musculoskelet Disord, 2011, 12: 33. DOI:10.1186/1471-2474-12-33.
KIM Y Y, CHOI W S and RHYU K W. Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study[J]. Spine J, 2012, 12(2): 164-168. DOI:10.1016/j.spinee.2012.01.014.
YU T, ZHANG X, LIU J, et al . Superior cortical screw in osteoporotic lumbar vertebrae: A biomechanics and microstructure-based study[J ] . Clin Biomech, 2018, 53: 14-21. DOI:10.1016/j.clinbiomech.2018.01.017.
ZHUANG X M, YU B S, ZHENG Z M, et al . Effect of the degree of osteoporosis on the biomechanical anchoring strength of the sacral pedicle screws: an in vitro comparison between unaugmented bicortical screws and polymethylmethacrylate augmented unicortical screws[J ] .Spine, 2010, 35(19):925-931.
SHI L, WANG L, GUO Z, et al . A study of low elastic modulus expandable pedicle screws in osteoporotic sheep[J ] . J Spinal Disord Tech, 2012, 25(2): 123-128. DOI:10.1097/BSD.0b013e31820ef9f7.
KIYAK G, BALIKCI T, HEYDAR A M, et al . Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model[J ] . Asian Spine J, 2018, 12(1): 3-11. DOI:10.4184/asj.2018.12.1.3.
LIU D, SHENG J, LUO Y, et al . Biomechanical comparative study of the stability of injectable pedicle screws with different lateral holes augmented with different volumes of polymethylmethacrylate in osteoporotic lumbar vertebrae[J ] . Spine J, 2018. DOI:10.1016/j.spinee.2018.03.009.
BECKER S, CHAVANNE A, SPITALER R, et al . Assessment of different screw augmentation techniques and screw designs in osteoporotic spines[J ] . Eur Spine J, 2008, 17(11): 1462-1469. DOI:10.1007/s00586-008-0769-8.
JANSSEN I, RYANG Y M, GEMPT J, et al . Risk of cement leakage and pulmonary embolism by bone cement-augmented pedicle screw fixation of the thoracolumbar spine[J ] . Spine J, 2017, 17(6): 837-844. DOI:10.1016/j.spinee.2017.01.009.
MARTIN-FERNANDEZ M, LOPEZ-HERRADON A, PINERA A R, et al . Potential risks of using cement-augmented screws for spinal fusion in patients with low bone quality[J ] . Spine J, 2017, 17(8): 1192-1199. DOI:10.1016/j.spinee.2017.04.029.
STADELMANN V A, BRETTON E, TERRIER A, et al . Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation[J ] . J Biomech, 2010, 43(15): 2869-2874. DOI:10.1016/j.jbiomech.2010.07.025.
MOON B J, CHO B Y, CHOI E Y, et al . Polymethylmethacrylate-augmented screw fixationfor stabilization of the osteoporotic spine: a three-year follow-up of 37 patients[J ] . J Korean Neurosurg Soc, 2009, 46(4): 305-311. DOI:10.3340/jkns.2009.46.4.305.
LIU Y, XU J, SUN D, et al . Biomechanical and finite element analyses of bone cement-Injectable cannulated p edicle screw fixation in osteoporotic bone[J ] . J Biomed Mater Res Part B Appl Biomater, 2016, 104(5): 960-967. DOI:10.1002/jbm.b.33424.
DAI F, LIU Y, ZHANG F, et al . Surgical treatment of the osteoporotic spine with bone cement-injectable cannulated pedicle screw fixation: technical description and preliminary application in 43 patients[J ] . Clinics, 2015, 70(2): 114- 119. DOI:10.6061/clinics/2015(02)08.
PATEL P S, SHEPHERD D E, HUKINS D W. The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models[J]. Med Eng Phys, 2010, 32(8): 822-828. DOI:10.1016/j.medengphy.2010.05.005.
VARGHESE V, SARAVANA KUMAR G, KRISHNAN V. Effect of various factors on pull out strength of pedicle screw in normal and osteoporotic cancellous bone models[J]. Med Eng Phys, 2017, 40: 28-38. DOI:10.1016/j.medengphy.2016.11.012.
LORENZ A, LEICHTLE C I, FRANTZ S, et al . Pull out Strength of Dual OuterDiameter Pedicle Screws Compared to Uncemented and Cemented Standard Pedicle Screws: A Biomechanical in vitro Study[J ] . Orthop Surg, 2017, 9(2): 229-236. DOI:10.1111/os.12322.
CHANDRA V V, PRASAD B C, JAGADEESH M A, et al . Segmental polymethylmethacrylate-augmented fenestrated pedicle screw fixation for lumbar spondylolisthesis in patients with osteoporosis-A case series and review of literature[J ] . Neurol India, 2017, 65(1): 89-95. DOI:10.4103/0028-3886.198229.
孙浩林, 李淳德, 杨泽川, 等.多孔中空椎弓根螺钉骨水泥加强固定治疗合并骨质疏松症的腰椎退变性疾病[J].北京大学学报(医学版), 2016, 48(6): 1019-1025. DOI:10.3969/j.issn.1671-167X.2016.06.017.
SUN H L, LI C D, YANG Z C, et al . Polymethylmethacrylate augmentation of bone cement-injectable cannulated pediclescrews for the treatment of degenerative lumbar diseases with osteoporosis[J ] . J Peking Univ (Health Sciences), 2016, 48(6): 1019-1025. DOI:10.3969/j.issn.1671-167X.2016.06.017.
SHEA T M, LAUN J, GONZALEZ-BLOHM S A, et al . Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae: current status[J ] . Biomed Res Int, 2014, 2014: 748393. DOI:10.1155/2014/748393.
FRANKEL B M, JONES T, WANG C. Segmental polymethylmethacrylate-augmented pedicle screw fixation in patients with bone softening caused by osteoporosis and metastatic tumor involvement: a clinical evaluation[J]. Neurosurgery, 2007, 61(3): 531-537. DOI:10.1227/01.NEU.0000290899.15567.68.
MUMMANENI P V, HADDOCK S M, LIEBSCHNER M A, et al . Biomechanical evaluation of a double-threaded pedicle screw in elderly vertebrae[J ] . J Spinal Disord Tech, 2002, 15(1): 64-68. DOI:10.1097/00024720-200202000-00012.
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621