
浏览全部资源
扫码关注微信
重庆市妇幼保健院、重庆医科大学附属妇女儿童医院儿一科/新生儿救治中心,重庆 401147
王 琪,Email:wangqizi520@126.com,研究方向:早产儿救治。
钟晓云,Email:13883519380@163.com。
收稿:2023-12-04,
修回:2024-01-15,
录用:2024-02-28,
纸质出版:2024-09-28
移动端阅览
王琪,钟晓云,吴艳.早产儿产房内持续气道正压通气支持不同连接装置治疗效果比较[J].重庆医科大学学报,2024,49(9):1171-1174.
Wang Qi,Zhong Xiaoyun,Wu Yan.Comparison of therapeutic effects of continuous positive airway pressure with different connection devices for premature infants in delivery room[J].Journal of Chongqing Medical University,2024,49(9):1171-1174.
王琪,钟晓云,吴艳.早产儿产房内持续气道正压通气支持不同连接装置治疗效果比较[J].重庆医科大学学报,2024,49(9):1171-1174. DOI: 10.13406/j.cnki.cyxb.003579.
Wang Qi,Zhong Xiaoyun,Wu Yan.Comparison of therapeutic effects of continuous positive airway pressure with different connection devices for premature infants in delivery room[J].Journal of Chongqing Medical University,2024,49(9):1171-1174. DOI: 10.13406/j.cnki.cyxb.003579.
目的
2
比较极早产儿产房内复苏时使用双鼻孔鼻导管或面罩连接持续气道正压通气的治疗效果。
方法
2
选择2021年6月至2023年1月在重庆市妇幼保健院出生的极早产儿共249例,依据出生后持续气道正压通气不同连接方式分为双鼻导管组(124例)和面罩组(125例),比较2组的复苏效果、住院情况及并发症发生情况。
结果
2
在复苏时经双鼻导管连接持续气道正压通气提供持续气道正压的早产儿,生后1 h内血气分析pH值高于面罩组(
P
<
0.05)、PaCO
2
值低于面罩组(
P
<
0.05),进入新生儿重症监护病房时的吸氧浓度低于面罩组(
P
<
0.05),2组早产儿心率
>
100次/min的时间、经皮氧饱和度(SpO
2
)
>
80%的时间、复苏时气管插管率以及生后5 min的Apgar评分差异无统计学意义,2组早产儿Ⅲ~Ⅳ度早产儿脑室周围-脑室内出血发生率、Ⅱ期以上坏死性小肠结肠炎发生率、支气管肺发育不良发生率、早产儿视网膜病发生率差异无统计学意义。
结论
2
产房内使用双鼻孔鼻导管连接持续气道正压通气提供持续气道正压在改善二氧化碳潴留、减轻酸中毒等方面优于面罩,且不增加早产儿严重并发症的发生,可用于极早产儿产房内稳定。
Objective
2
To compare the therapeutic effects of continuous positive airway pressure(CPAP) connected with a dual nasal cannula or a mask during delivery room resuscitation for very premature infants.
Methods
2
We included 249 very premature infants born in the Chong Qing Health Center for Women and Children from June 2021 to January 2023,including 124 infants treated with CPAP with a dual nasal cannula and 125 infants treated with CPAP with a mask. The resuscitation effect,hospitalization status,and complications of the two groups were compared.
Results
2
Compared with the mask group,the premature infants who received CPAP through a dual nasal cannula during resuscitation had a significantly higher blood pH value within 1 hour after birth(
P
<
0.05),a significantly lower blood PaCO
2
value(
P
<
0.05),and a significantly lower fraction of inspired oxygen when entering the neonatal intensive care unit(
P
<
0.05). There were no significant differences between the two groups in terms of the duration of heart rate
>
100 beats per minute,the duration of saturation of peripheral oxygen(SpO
2
)
>
80%,the tracheal intubation rate during resuscitation,and the Apgar score at 5 minutes after birth. The two groups showed no significant differences in the incidence rates of periventricular-intraventricular hemorrhage of grade Ⅲ-Ⅳ,necrotizing enterocolitis of stage Ⅱ or higher,bronchopulmonary dysplasia,and retinopathy of prematurity.
Conclusion
2
The use of dual nasal cannulas to connect CPAP in the delivery room is superior to masks in reducing carbon dioxide retention and acidosis,without increasing the occurrence of serious complications in preterm infants,which can be used to stabilize the conditions of very preterm infants in the delivery room.
茹喜芳 , 冯 琪 . 新生儿呼吸窘迫综合征的防治:欧洲共识指南2022版 [J ] . 中华新生儿科杂志(中英文) , 2023 , 38 ( 3 ): 191 - 192 .
Ru XF , Feng Q . European consensus guidelines on the management of respiratory distress syndrome:2022 update [J ] . Chin J Neonatol , 2023 , 38 ( 3 ): 191 - 192 .
Ru XF , Feng Q . Management of neonatal respiratory distress syndrome:European Consensus Guidelines 2022 [J ] . Chin J Neonatol , 2023 , 38 ( 3 ): 191 - 192 .
Kakkilaya V , Jubran I , Mashruwala V , et al . Quality improvement project to decrease delivery room intubations in preterm infants [J ] . Pediatrics , 2019 , 143 ( 2 ): e20180201 .
高建慧 , 赖春华 , 彭嘉恒 , 等 . 新生儿喉罩复苏效果及远期神经心理发育评估 [J ] . 中国妇幼健康研究 , 2019 , 30 ( 7 ): 787 - 791 .
Gao JH , Lai CH , Peng JH , et al . Evaluation of neonatal laryngeal mask resuscitation effect and long-term neuropsychological development [J ] . Chin J Woman Child Health Res , 2019 , 30 ( 7 ): 787 - 791 .
邵肖梅 , 叶鸿瑁 , 丘小汕 . 实用新生儿学 [M ] . 5版 . 北京 : 人民卫生出版社 , 2019 .
Shao XM , Ye HM , Qiu XS . Practical neonatology [M ] . 5th ed . Beijing : People's Medical Publishing House , 2019 .
Subramaniam P , Ho JJ , Davis PG . Prophylactic nasal continuous positive airway pressure for preventing morbidity and mortality in very preterm infants [J ] . Cochrane Database Syst Rev , 2016 ( 6 ): CD001243 .
欧姜凤 , 钟晓云 , 吴艳 , 等 . 2017年至2019年复苏质量改进情况及其对极低出生体重儿复苏效果的影响 [J ] . 中华围产医学杂志 , 2020 , 23 ( 9 ): 600 - 607 .
Ou JF , Zhong XY , Wu Y , et al . Resuscitation quality improvement and its outcomes in very low birth weight infants from 2017 to 2019 [J ] . Chin J Perinat Med , 2020 , 23 ( 9 ): 600 - 607 .
Kaufman J , Schmölzer GM , Kamlin CO , et al . Mask ventilation of preterm infants in the delivery room [J ] . Arch Dis Child Fetal Neonatal Ed , 2013 , 98 ( 5 ): F405 - F410 .
赖春华 , 高建慧 , 陈志君 , 等 . 早产儿/低出生体重儿应用国产喉罩复苏的效果分析 [J ] . 现代医院 , 2020 , 20 ( 6 ): 903 - 906,910 .
Lai CH , Gao JH , Chen ZJ , et al . Effect analysis of resuscitation of domestic laryngeal mask for premature infants/low birth weight infants [J ] . Modern Hospitals , 2020 , 20 ( 6 ): 903 - 906,910 .
McCarthy LK , Twomey AR , Molloy EJ , et al . A randomized trial of nasal prong or face mask for respiratory support for preterm newborns [J ] . Pediatrics , 2013 , 132 ( 2 ): e389 - e395 .
Kamlin CO , Schilleman K , Dawson JA , et al . Mask versus nasal tube for stabilization of preterm infants at birth:a randomized controlled trial [J ] . Pediatrics , 2013 , 132 ( 2 ): e381 - e388 .
van Vonderen JJ , Kamlin CO , Dawson JA , et al . Mask versus nasal tube for stabilization of preterm infants at birth:respiratory function measurements [J ] . J Pediatr , 2015 , 167 ( 1 ): 81 - 85 .
0
浏览量
8
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621