浏览全部资源
扫码关注微信
1.重庆大学医学院智慧检验与分子医学中心,重庆 400044
2.重庆市第一实验中学校,重庆 400030
3.山东大学第二医院检验医学中心,济南 250033
刘睿宁,Email:liurn122@163.com, 研究方向:疾病快速检测技术研究。
罗 阳,Email:luoy@cqu.edu.cn。
收稿:2022-06-16,
纸质出版:2022-08-28
移动端阅览
刘睿宁,陈太菊,刘宏杰,等.可穿戴传感技术在检验医学中的应用与挑战[J].重庆医科大学学报,2022,47(8):877-882.
Liu Ruining,Chen Taiju,Liu Hongjie,et al.Applications and challenges of wearable sensing technology in laboratory medicine[J].Journal of Chongqing Medical University,2022,47(8):877-882.
刘睿宁,陈太菊,刘宏杰,等.可穿戴传感技术在检验医学中的应用与挑战[J].重庆医科大学学报,2022,47(8):877-882. DOI: 10.13406/j.cnki.cyxb.003080..
Liu Ruining,Chen Taiju,Liu Hongjie,et al.Applications and challenges of wearable sensing technology in laboratory medicine[J].Journal of Chongqing Medical University,2022,47(8):877-882. DOI: 10.13406/j.cnki.cyxb.003080..
可穿戴传感技术因其无创、便携等特征被广泛用于生物医学领域,尤其是对检验医学生物标志物的监测发挥重要作用。随着可穿戴传感技术从传统刚性结构到柔性贴片的发展,其灵敏度、特异性、稳定性、实用性等性能获得极大提升。本文就可穿戴传感技术在检验医学中的应用与挑战进行综述,分析其在葡萄糖、电解质等小分子监测中的优势与不足,展望其未来发展方向,为推动检验医学新技术发展提供参考。
Wearable sensing technology has been widely used in biomedical field because of its non-invasive and portable characteristics, and especially in the monitoring of medical biomarkers. From the conventional rigid structure to flexible patch, wearable sensing technology has been greatly enhanced in terms of sensitivity,specificity, stability and practicality. This paper reviews its application and challenges of laboratory medicine, analyzes its pros and cons in the monitoring of small molecules such as glucose and electrolyte, and looks forward to its future prospects, so as to provide reference for promoting the development of new technologies in laboratory medicine.
Mingrone G , Panunzi S , de Gaetano A , et al . Metabolic surgery versus conventional medical therapy in patients with type 2 diabetes:10-year follow-up of an open-label,single-centre,randomised controlled trial [J ] . Lancet , 2021 , 397 ( 10271 ): 293 - 304 .
Zhang WL , Zhang SY , Deng Y , et al . Trial of intensive blood-pressure control in older patients with hypertension [J ] . N Engl J Med , 2021 , 385 ( 14 ): 1268 - 1279 .
Mitratza M , Goodale BM , Shagadatova A , et al . The performance of wearable sensors in the detection of SARS-CoV-2 infection:a systematic review [J ] . Lancet Digit Health , 2022 , 4 ( 5 ): e370 - e383 .
Sreenilayam SP , Ahad IU , Nicolosi V , et al . Advanced materials of printed wearables for physiological parameter monitoring [J ] . Mater Today , 2020 , 32 : 147 - 177 .
Gao W , Ota H , Kiriya D , et al . Flexible electronics toward wearable sensing [J ] . Acc Chem Res , 2019 , 52 ( 3 ): 523 - 533 .
Dervisevic M , Alba M , Prieto-Simon B , et al . Skin in the diagnostics game:wearable biosensor nano- and microsystems for medical diagnostics [J ] . Nano Today , 2020 , 30 : 100828 .
Hong YJ , Jeong H , Cho KW , et al . Wearable and implantable devices for cardiovascular healthcare:from monitoring to therapy based on flexible and stretchable electronics [J ] . Adv Funct Mater , 2019 , 29 ( 19 ): 1808247 .
Gao JY , Shang KZ , Ding YC , et al . Material and configuration design strategies towards flexible and wearable power supply devices:a review [J ] . J Mater Chem A , 2021 , 9 ( 14 ): 8950 - 8965 .
Liu C , Zhang BJ , Chen WT , et al . Current development of wearable sensors based on nanosheets and applications [J ] . Trac Trends Anal Chem , 2021 , 143 : 116334 .
Chen G , Zheng JG , Liu LY , et al . Application of microfluidics in wearable devices [J ] . Small Methods , 2019 , 3 ( 12 ): 1900688 .
Wang ZY , Luan JY , Seth A , et al . Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid [J ] . Nat Biomed Eng , 2021 , 5 ( 1 ): 64 - 76 .
Bergenstal RM . Continuous glucose monitoring:transforming diabetes management step by step [J ] . Lancet , 2018 , 391 ( 10128 ): 1334 - 1336 .
Gao Y , Huang Y , Ge JL , et al . An interrelated CataFlower enzyme system for sensitively monitoring sweat glucose [J ] . Talanta , 2021 , 235 : 122799 .
Zhao JQ , Lin YJ , Wu JB , et al . A fully integrated and self-powered smartwatch for continuous sweat glucose monitoring [J ] . ACS Sens , 2019 , 4 ( 7 ): 1925 - 1933 .
Huang XC , Li JY , Liu YM , et al . Epidermal self-powered sweat sensors for glucose and lactate monitoring [J ] . Bio-des Manuf , 2022 , 5 ( 1 ): 201 - 209 .
Kim J , Campbell AS , de Ávila BEF , et al . Wearable biosensors for healthcare monitoring [J ] . Nat Biotechnol , 2019 , 37 ( 4 ): 389 - 406 .
Dervisevic M , Alba M , Yan L , et al . Transdermal electrochemical monitoring of glucose via high-density silicon microneedle array patch [J ] . Adv Funct Materials , 2022 , 32 ( 3 ): 2270022 .
Bandodkar AJ , Jia WZ , Yardımcı C , et al . Tattoo-based noninvasive glucose monitoring:a proof-of-concept study [J ] . Anal Chem , 2015 , 87 ( 1 ): 394 - 398 .
Lin PH , Sheu SC , Chen CW , et al . Wearable hydrogel patch with noninvasive,electrochemical glucose sensor for natural sweat detection [J ] . Talanta , 2022 , 241 : 123187 .
Lin YJ , Bariya M , Nyein HYY , et al . Porous enzymatic membrane for nanotextured glucose sweat sensors with high stability toward reliable noninvasive health monitoring [J ] . Adv Funct Mater , 2019 , 29 ( 33 ): 1902521 .
Chen YH , Lu SY , Zhang SS , et al . Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring [J ] . Sci Adv , 2017 , 3 ( 12 ): e1701629 .
Lee WC , Kim KB , Gurudatt NG , et al . Comparison of enzymatic and non-enzymatic glucose sensors based on hierarchical Au-Ni alloy with conductive polymer [J ] . Biosens Bioelectron , 2019 , 130 : 48 - 54 .
Ray TR , Ivanovic M , Curtis PM , et al . Soft,skin-interfaced sweat stickers for cystic fibrosis diagnosis and management [J ] . Sci Transl Med , 2021 , 13 ( 587 ): eabd8109 .
Choi DH , Thaxton A , Jeong IC , et al . Sweat test for cystic fibrosis:Wearable sweat sensor vs . standard laboratory test [J ] . J Cyst Fibros , 2018 , 17 ( 4 ): e35 - e38 .
Vernooij-van Langen A , Dompeling E , Yntema JB , et al . Clinical evaluation of the Nanoduct sweat test system in the diagnosis of cystic fibrosis after newborn screening [J ] . Eur J Pediatr , 2015 , 174 ( 8 ): 1025 - 1034 .
Yang YR , Song Y , Bo XJ , et al . A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat [J ] . Nat Biotechnol , 2020 , 38 ( 2 ): 217 - 224 .
Sekine Y , Kim SB , Zhang Y , et al . A fluorometric skin-interfaced microfluidic device and smartphone imaging module for in situ quantitative analysis of sweat chemistry [J ] . Lab Chip , 2018 , 18 ( 15 ): 2178 - 2186 .
He XC , Yang SJ , Pei QB , et al . Integrated smart Janus textile bands for self-pumping sweat sampling and analysis [J ] . ACS Sens , 2020 , 5 ( 6 ): 1548 - 1554 .
Ardalan S , Hosseinifard M , Vosough M , et al . Towards smart personalized perspiration analysis:an IoT-integrated cellulose-based microfluidic wearable patch for smartphone fluorimetric multi-sensing of sweat biomarkers [J ] . Biosens Bioelectron , 2020 , 168 : 112450 .
Zheng YB , Omar R , Zhang RJ , et al . A wearable microneedle‐based extended gate transistor for real‐time detection of sodium in interstitial fluids [J ] . Adv Mater , 2022 , 34 ( 10 ): 2270079 .
Li JZ , Lu HT , Wang YY , et al . Interstitial fluid biomarkers’ minimally invasive monitoring using microneedle sensor arrays [J ] . Anal Chem , 2022 , 94 ( 2 ): 968 - 974 .
Teymourian H , Moonla C , Tehrani F , et al . Microneedle-based detection of ketone bodies along with glucose and lactate:toward real-time continuous interstitial fluid monitoring of diabetic ketosis and ketoacidosis [J ] . Anal Chem , 2020 , 92 ( 2 ): 2291 - 2300 .
Fonseca DFS , Costa PC , Almeida IF , et al . Swellable gelatin methacryloyl microneedles for extraction of interstitial skin fluid toward minimally invasive monitoring of urea [J ] . Macromol Biosci , 2020 , 20 ( 10 ): 2000195 .
Rathee K , Dhull V , Dhull R , et al . Biosensors based on electrochemical lactate detection:a comprehensive review [J ] . Biochem Biophys Rep , 2016 , 5 : 35 - 54 .
Jia WZ , Bandodkar AJ , Valdés-Ramírez G , et al . Electrochemical tattoo biosensors for real-time noninvasive lactate monitoring in human perspiration [J ] . Anal Chem , 2013 , 85 ( 14 ): 6553 - 6560 .
Zhang LL , Liu J , Fu ZL , et al . A wearable biosensor based on bienzyme gel-membrane for sweat lactate monitoring by mounting on eyeglasses [J ] . J Nanosci Nanotechnol , 2020 , 20 ( 3 ): 1495 - 1503 .
Zhang YP , Yu HJ , Chai SW , et al . Noninvasive and individual-centered monitoring of uric acid for precaution of hyperuricemia via optical supramolecular sensing [J ] . Adv Sci , 2022 , 9 ( 18 ): 2104463 .
Wang YX , Tsao PK , Rinawati M , et al . Designing ZIF-67 derived NiCo layered double hydroxides with 3D hierarchical structure for Enzyme-free electrochemical lactate monitoring in human sweat [J ] . Chem Eng J , 2022 , 427 : 131687 .
Wang B , Zhao CZ , Wang ZQ , et al . Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring [J ] . Sci Adv , 2022 , 8 ( 1 ): eabk0967 .
Weng X , Fu ZY , Zhang C , et al . A portable 3D microfluidic origami biosensor for cortisol detection in human sweat [J ] . Anal Chem , 2022 , 94 ( 8 ): 3526 - 3534 .
Cheng C , Li X , Xu G , et al . Battery-free,wireless,and flexible electrochemical patch for in situ analysis of sweat cortisol via near field communication [J ] . Biosens Bioelectron , 2021 , 172 : 112782 .
Yang B , Fang XE , Kong JL . In situ sampling and monitoring cell-free DNA of the Epstein-Barr virus from dermal interstitial fluid using wearable microneedle patches [J ] . ACS Appl Mater Interfaces , 2019 , 11 ( 42 ): 38448 - 38458 .
He WY , Wang CY , Wang HM , et al . Integrated textile sensor patch for real-time and multiplex sweat analysis [J ] . Sci Adv , 2019 , 5 ( 11 ): eaax0649 .
0
浏览量
3
下载量
2
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621