
浏览全部资源
扫码关注微信
纸质出版:2016
移动端阅览
付有晴,娄季武,赵颖,蔡婉芳,颜妙丽,瞿京辉,徐婉芳,何怡,林洋洋,叶菀华,周光纪,刘彦慧.胎儿染色体非整倍体无创基因检测试剂盒的临床验证[J].陆军军医大学学报(原第三军医大学学报),2016,38(01):97-100.
Fu Youqing,Lou Jiwu,Zhao Ying,Cai Wanfang,Yan Miaoli,Qu Jinghui,Xu Wanfang,He Yi,Lin Yangyang,Ye Wanhua,Zhou Guangji,Liu Yanhui.Clinical validation of noninvasive genetic testing kit of fetal chromosomal aneuploidy[J].J Amry Med Univ (J Third Mil Med Univ),2016,38(01):97-100.
付有晴,娄季武,赵颖,蔡婉芳,颜妙丽,瞿京辉,徐婉芳,何怡,林洋洋,叶菀华,周光纪,刘彦慧.胎儿染色体非整倍体无创基因检测试剂盒的临床验证[J].陆军军医大学学报(原第三军医大学学报),2016,38(01):97-100. DOI:
Fu Youqing,Lou Jiwu,Zhao Ying,Cai Wanfang,Yan Miaoli,Qu Jinghui,Xu Wanfang,He Yi,Lin Yangyang,Ye Wanhua,Zhou Guangji,Liu Yanhui.Clinical validation of noninvasive genetic testing kit of fetal chromosomal aneuploidy[J].J Amry Med Univ (J Third Mil Med Univ),2016,38(01):97-100. DOI:
目的 验证胎儿染色体非整倍体(T21、T18、T13)基因检测试剂盒(联合探针锚定连接测序法)在临床检测上的准确性和有效性。 方法 选择广东省东莞市妇幼保健院的孕妇外周血样本,采用胎儿染色体非整倍体(T21、T18、T13)基因检测试剂盒通过联合探针锚定连接测序法检测,并将结果与临床诊断金标准染色体核型分析结果或出生随访结果作对比。对灵敏度、特异性、总符合率和一致性系数Kappa值进行评价,以验证该试剂盒在临床检测上的准确性和有效性。 结果 共完成有效样本389例,测序法检出T21阳性6例,T18和T13均未检出阳性,与染色体核型分析结果相符,检测为阴性共383例,经电话随访至出生未发现非整倍体胎儿。统计分析结果显示,测序法与核型分析法总符合率为100%,Kappa=1(≥0.8),其中检测T21的灵敏度、特异性、阳性预测值、阴性预测值均为100%;检测T18和T13的特异性、阴性预测值均为100%。 结论 采用试剂盒通过联合探针锚定连接测序法检测T21、T18、T13的结果准确度高且方法安全,可以在临床上推广使用。
Objective To verify the accuracy and effectiveness of a genetic detection kit for noninvasive fetal trisomy (T21
T18 and T13
based on combinatorial probe-anchor ligation sequencing
a product of BGI Biotechnology Limited Co.) in clinical practice. Methods Pregnant women who underwent prenatal diagnosis in our hospital were recruited in this study. Maternal peripheral blood samples were collected from each participant
and then processed in accordance with the kit instructions followed by combinatorial probe-anchor ligation sequencing. The results were compared with the results from prenatal karyotyping confirmation and baby born. The sensitivity
specificity
overall compliance rate and consistency coefficient Kappa values were evaluated to verify the accuracy and validity of the kit in the clinical testing. Results A total of 389 valid samples was tested using this genetic testing kit. Six pregnant women were found carrying trisomy 21 fetuses by sequencing
and none of them carrying trisomy 18 or 13 fetus
which consistent with the results of karyotyping. The other 383 women were negative
which was further validated by telephone follow-up after baby born. Statistical analysis showed that the total coincidence rate of our sequencing and karyotyping was 100% and the Kappa=1 (≥0.8)
indicating that the sensitivity
specificity
positive predictive value and negative predictive value of trisomy 21 were 100%
and the specificity
negative predictive value of trisomy 18 and trisomy 13 were 100%. Conclusion This genetic detection kit for noninvasive fetal trisomy is of high accuracy and security
and should be worth of extensive application in clinic.
0
浏览量
0
下载量
0
CSCD
关联资源
相关文章
相关作者
相关机构
京公网安备11010802024621