目的 建立胸部放疗中纵隔淋巴结剂量监测的辐照仿真模型,为临床上监测纵隔淋巴结的实际受照剂量提供实验依据。 方法 以标准中国人体(身高170 cm、体质量65 kg)为参照,选取20例相近体型的男性胸部肿瘤患者,运用瓦里安公司的Eclipse治疗计划系统(treatment planning system
TPS)确定纵隔淋巴结分布区的三维定位点;根据定位点和三维立体数据,对辐照仿真体模(以下简称体模)进行打孔;根据辐射监测探头的形状和大小,安装辐射剂量监测设备。 结果 通过Eclipse系统,精确定位了标准中国人体的纵隔淋巴结各分区中心点,并在胸部CT图像横断面、矢状面和冠状面上测量了标准中国人体的三维定位平均数据;利用该数据在体模上实施精确打孔,并安装辐射剂量监测装置,建立了纵隔淋巴结辐射剂量监测的仿真模型。 结论 建立了胸部放疗中纵隔淋巴结剂量监测的辐照仿真模型,实现了精确打孔并安装了探测设备。
Objective To establish an irradiation simulation model for monitoring dose of mediastinal lymph nodes in thoracic radiotherapy and provide the experimental basis for monitoring the actual dose of the lymph nodes in clinical setting. Methods Based on the standard height of Chinese men (height 170 cm
weight 65 kg)
20 male chest cancer patients with similar somatotype were recruited in this study. Varian’s Eclipse treatment planning system (TPS) was used to determine the three-dimensional positioning point of mediastinal lymph node distribution areas. The irradiation simulation phantom (hereinafter referred to as phantom) was drilled according to the positioning point and the three-dimensional data. Equipment for monitoring radiation dose was installed according to the shape and size of the radiation monitoring probe. Results The central points of the distribution areas in the mediastinal lymph nodes were accurately positioned using the Eclipse system. The average three-dimensional positioning data of standard Chinese men were measured on cross-sectional
sagittal and coronal planes of the chest CT images based on these accurate data. The phantom was accurately punched and the devices for monitoring radiation dose were installed
leading to the establishment of an irradiation simulation model for monitoring the dose of mediastinal lymph nodes. Conclusion An irradiation simulation model for monitoring dose of mediastinal lymph nodes in thoracic radiotherapy is established
which offering the accurate punching and installation of detection equipment. This model lays the foundation for the studies of dosimetry of thoracic radiotherapy.