Zhao Jun,Chen Wei,Zhou Daiquan,Wang Jian,Peng Xu,Duan Xiaojun,Li Chuan,Wen Yaming.Diagnosis of meniscal tear of knee joint by SWI sequence: a feasibility study[J].J Amry Med Univ (J Third Mil Med Univ),2012,34(19):2002-2004.
Zhao Jun,Chen Wei,Zhou Daiquan,Wang Jian,Peng Xu,Duan Xiaojun,Li Chuan,Wen Yaming.Diagnosis of meniscal tear of knee joint by SWI sequence: a feasibility study[J].J Amry Med Univ (J Third Mil Med Univ),2012,34(19):2002-2004.DOI:
Objective To study the feasibility of susceptibility weighted imaging in diagnosis of meniscus tear of knee joint. Methods Forty patients with suspected meniscus tear of knee joint underwent MRI scanning of T
1
WI
T
2
WI-FS and SWI sequences. The sensitivity
specificity
accuracy and diagnostic outcome of T
1
WI
T
2
WI-FS and SWI sequences were compared with arthroscopy as the golden standards. Results The sensitivity
specificity and accuracy of T
1
WI
T
2
WI-FS and SWI sequence
s were 76.3%
50.0% and 75.0%
respectively; 71.1%
100.0% and 72.5%
respectively; and 94.7%
50.0% and 92.5%
respectively
for the diagnosis of meniscus tear of knee joint. The consistency of T
1
WI and T
2
WI-FS sequences was poorer than that of SWI sequence in diagnosis of meniscus tear of knee joint (P0.05). The Kappa value was 0.391 and 0.288
respectively
for T
2
WI-FS and SWI sequences. The diagnostic outcomes of meniscus tear of knee joint were significantly different between T
2
WI-FS and SWI sequences (P0.05). Conclusion The SWI sequence can be used in diagnosis of meniscus tear of knee joint
and its sensitivity and accuracy are better than the T