BAO Minmin,LYU Beibei,WEI Wenzhi,et al.Method establishment for content determination of related substances in Oxcarbazepine tablets[J].ZHONGGUO YAOFANG,2023,34(10):1199-1203.
BAO Minmin,LYU Beibei,WEI Wenzhi,et al.Method establishment for content determination of related substances in Oxcarbazepine tablets[J].ZHONGGUO YAOFANG,2023,34(10):1199-1203. DOI: 10.6039/j.issn.1001-0408.2023.10.09.
Method establishment for content determination of related substances in Oxcarbazepine tablets
To establish the method for content determination of related substances in Oxcarbazepine tablets.
METHODS
2
Ultra-high performance liquid chromatography (UPLC) method was adopted and the separation was performed on ZORBAX Eclipse Plus C
18
column with mobile phase consisted of acetonitrile-0.01 mol/L ammonium acetate solution (pH6.0) (gradient elution) at the flow rate of 0.5 mL/min. The detection wavelength was 230 nm and column temperature was set at 35 ℃. The sample size was 10 μL.
RESULTS
2
The linear ranges of oxcarbazepine and impurity A, B, C, D, E, I, K, L and N were 0.192-1.440, 1.019-7.639, 0.208-1.559, 0.230-1.727, 0.389-2.915, 0.182-1.364, 0.393-2.945, 0.199-1.493, 0.199-1.490 and 0.200-1.503 μg/mL, respectively (all
r
>0.999). The detection limits were 0.046, 0.037, 0.049, 0.027, 0.077, 0.040, 0.114, 0.054, 0.055 and 0.039 μg/mL. The quantitation limits were 0.152, 0.122, 0.162, 0.090, 0.258, 0.132, 0.380, 0.181, 0.185 and 0.130 μg/mL. RSDs of precision, repeatability, stability (24 h) and durability tests were all lower than 5.0%. The average recoveries were 92.8%-105.6% (RSD≤3.0%,
n
=9). Only impurity K and unknown impurity were detected in the original preparation sample, with a total content of 0.078% to 0.083%; impurities A, B, D, I and unknown impurity were detected in the generic preparations produced by domestic enterprise Ⅰ, with a total content of 0.147% to 0.163%; impurities A, B, I and unknown impurity were detected in the generic preparations produced by domestic enterprise Ⅱ, with a total content of 0.085% to 0.161%.
CONCLUSIONS
2
The established method is rapid, sensitive, accurate, stable and durable. It can be used for the content determination of 9 known impurities in Oxcarbazepine tablets.
VELUGULA S R K , REDDY A S K , MISRA N C , et al . Synthesis and characterization of potential impurities of oxcarbazepine drug substance:an antiepileptic agent [J ] . J Heterocycl Chem , 2021 , 58 ( 8 ): 1581 - 1587 .
FAUDONE S N , PASCHOAL A R , CARVALHO P S , Jr , et al . X-ray diffraction,vibrational and thermal study of dibenzazepinodione,a pharmacopeial impurity of oxcarbazepine [J ] . J Mol Struct , 2019 , 1182 : 204 - 212 .
SUN Y H , LI M , HADIZADEH M H , et al . Theoretical insights into the degradation mechanisms,kinetics and eco-toxicity of oxcarbazepine initiated by OH radicals in aqueous environments [J ] . J Environ Sci(China) , 2023 , 129 : 189 - 201 .
Quality evaluation of Xintong granules based on HPLC fingerprint and quantitative analysis of multi-components by single-marker method
Study on fingerprint establishment, content determination, and spectrum-effect relationship of in vitro antioxidant activity for Bushen ningshen ointment
Identification of tortoiseshell glue and antler glue in Qixiong zuogui granules and content determination of 12 chemical components
Establishment of HPLC fingerprint and content determination of multiple index components in Xiao’er resuqing oral liquid
Method establishment of component identification and content determination of 7 components in Mongolian medicine Ixeris chinensis
Related Author
YE Xide
FENG Xiaolong
SHAO Mingguo
WAN Linchun
HU Zhenyu
CHEN Chunyu
WU Yu
BU Junwen
Related Institution
Jiangxi Institute for Drug Control
Lunan Pharmaceutical Group Co., Ltd.
School of Pharmacy, Jiangxi University of Chinese Medicine