周希,单晶,邓梦怡,等.采用可调节光源改良宏观现场评估技术可显著提升EUS-FNA胰腺标本充足率与诊断准确率:一项随机交叉对照试验[J].陆军军医大学学报,2026,48(03):337-344.DOI:10.16016/j.2097-0927.202510082.
ZHOU X,SHAN J,DENG M Y,et al.Improved visualization with an adjustable-light modified macroscopic on-site evaluation technique enhances specimen adequacy and diagnostic accuracy in EUS-FNA for pancreatic lesions: A randomized crossover trial[J].J Army Med Univ,2026,48(03):337-344.DOI:10.16016/j.2097-0927.202510082.
周希,单晶,邓梦怡,等.采用可调节光源改良宏观现场评估技术可显著提升EUS-FNA胰腺标本充足率与诊断准确率:一项随机交叉对照试验[J].陆军军医大学学报,2026,48(03):337-344.DOI:10.16016/j.2097-0927.202510082. DOI:
ZHOU X,SHAN J,DENG M Y,et al.Improved visualization with an adjustable-light modified macroscopic on-site evaluation technique enhances specimen adequacy and diagnostic accuracy in EUS-FNA for pancreatic lesions: A randomized crossover trial[J].J Army Med Univ,2026,48(03):337-344.DOI:10.16016/j.2097-0927.202510082. DOI:
目的
2
明确改良宏观现场评估(macroscopic on-site evaluation ,MOSE)能否提升22G/25G FNA标本中核心组织条(macroscopic visible core,MVC)的可视化效果,进而提高标本充足率及病理诊断准确性。
方法
2
本研究为单中心、前瞻性、随机交叉对照试验,连续纳入2023年2月至2024年8月成都市第三人民医院消化内科拟行超声内镜引导下细针穿刺抽吸术(endoscopic ultrasound-guided fine needle aspiration,EUS-FNA)的胰腺实性占位患者90例。患者通过计算机生成的随机序列按1∶1分配至A组(第一针采用传统MOSE,第二针采用改良MOSE)或B组(第一针采用改良MOSE,第二针采用传统MOSE)。改良MOSE的核心参数为:白光强度调节范围为35~1 700 LUX,光源发光面与标本载玻片底部距离固定为37.2 mm,以MVC≥4 mm定义为标本充足。主要结局指标为2组的标本充足率,次要结局指标为细胞病理及组织病理诊断准确率。研究通过盲法评估(病理医师及数据分析人员不知情分组)、标准化操作流程控制偏倚。
结果
2
改良MOSE组的标本充足率显著高于传统MOSE组[70.0%(95%
CI
:59.9%~78.5%)
vs
43.3%(95%
CI
:33.6%~54.6%),
χ²
=13.714,
P
<
0.001]。次要结局方面,改良MOSE组的细胞病理诊断准确率[94.4%(95%
CI
: 87.7%~97.6%)
vs
85.6%(95%
CI
: 76.8%~91.4%)
χ
2
=4.9
P
=0.021)及组织条病理诊断准确率[95.6%(95%
CI
: 89.1%~98.3%)
vs
83.3%(95%
CI
: 76.8%~91.4%)
χ
2
=7.69
P
=0.003
]
均显著优于传统MOSE组。在针型的亚组分析中显示,在占比87.8%(79/90)的22G针型中,改良MOSE组的标本充足率[65.8%(95%
CI
:55.1%~76.5%)
vs
41.8%(95%
CI
:30.7%~52.9%),
P
=0.003]、细胞诊断准确率[93.7%(95%
CI
:88.1%~99.2%)
vs
84.8%(95%
CI
:76.7%~92.9%),
P
=0.039]、组织诊断准确率[94.9%(95%
CI
:90.0%~99.9%)
vs
82.3%(95%
CI
:73.7%~90.9%),
P
=0.013]比传统MOSE组更有优势。
结论
2
改良MOSE能提升22G/25G FNA标本中 MVC 的可视化效果,进而提高标本充足率及病理诊断准确性。
Objective
2
Determine whether a modified macroscopic on-site evaluation (MOSE) technique
by enhancing visualization of the macroscopic visible core (MVC) in 22G/25G fine needle aspiration (FNA) specimens
improves specimen adequacy and pathological diagnostic accuracy. Methods This single-center
prospective
randomized crossover trial enrolled 90 consecutive patients with solid pancreatic lesions scheduled for EUS-FNA from the Department of Gastroenter
ology at the Third People’s Hospital of Chengdu between February 2023 and August 2024. Patients were randomly assigned (1∶1)
via
a computer-generated sequence to Group A (first pass using traditional MOSE
second pass using modified MOSE) or Group B (first pass using modified MOSE
second pass using traditional MOSE). The core modification was the use of an adjustable white light source from 35 to 1 700 LUX at a fixed distance (37.2 mm) from the slide. Specimen adequacy was defined as MVC≥4 mm. The primary outcome was the specimen adequacy rate between groups. Secondary outcomes included the diagnostic accuracy of cytopathology and histopathology. Bias was controlled through blinded assessment (pathologists and data analysts were unaware of group allocation) and standardized operating procedures.
Results
2
The specimen adequacy rate was significantly higher in the modified MOSE group (70.0%
95%
CI
: 59.9 to 78.5%) than in the traditional MOSE group (43.3%
95%
CI
: 33.6 to 54.6%;
χ
²=13.714
P
<
0.001). The modified MOSE group also demonstrated superior diagnostic accuracy for both cytopathology [94.4%(95%
CI
: 87.7%~97.6%)
vs
85.6%(95%
CI
: 76.8%~91.4%)
χ
2
=4.9
P
=0.021) and histopathology of tissue strips [95.6%(95%
CI
: 89.1%~98.3%)
vs
83.3%(95%
CI
: 76.8%~91.4%)
χ
2
=7.69
P
=0.003
]
. Subgroup analysis based on needle gauge demonstrated that for the 22G needle
which constituted 87.8% (79/90) of cases
the modified MOSE demonstrated statistically significant advantages over the traditional MOSE in the following outcomes: specimen adequacy rate [65.8% (95%
CI
: 55.1% to 76.5%)
vs
41.8% (95%
CI
: 30.7% to 52.9%)
P
=0.003
]
cytological diagnostic accuracy [93.7% (9
5%
CI
: 88.1% to 99.2%)
vs
84.8% (95%
CI
: 76.7% to 92.9%)
P
=0.039
]
and histological diagnostic accuracy [94.9% (95%
CI
: 90.0% to 99.9%)
vs
82.3% (95%
CI
: 73.7% to 90.9%)
P
=0.013
]
.
Conclusion
2
Modified MOSE can enhance the visualization of the MVC in specimens obtained by 22G/25G FNA
thereby improving the specimen adequacy rate and pathological diagnostic accuracy.
LIU P , SUN Q Q , LIU T X , et al . Serum lncRNA-UFC1 as a potential biomarker for diagnosis and prognosis of pancreatic cancer [J]. Int J Clin Exp Pathol , 2019 , 12 ( 11 ): 4125 - 4129 .
YOSHINAGA S , ITOI T , YAMAO K , et al . Safety and efficacy of endoscopic ultrasound-guided fine needle aspiration for pancreatic masses: a prospective multicenter study [J]. Dig Endosc , 2020 , 32 ( 1 ): 114 - 126 . DOI: 10.1111/den.13457 http://dx.doi.org/10.1111/den.13457 .
YANG X , LIU Z M , ZHOU X , et al . Methods to increase the diagnostic efficiency of endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions: an updated review [J]. World J Gastrointest Endosc , 2024 , 16 ( 3 ): 117 - 125 . DOI: 10.4253/wjge.v16.i3.117 http://dx.doi.org/10.4253/wjge.v16.i3.117 .
MACHICADO J D , SHETH S G , CHALHOUB J M , et al . American Society for Gastrointestinal Endoscopy guideline on the role of endoscopy in the diagnosis and management of solid pancreatic masses: summary and recommendations [J]. Gastrointest Endosc , 2024 , 100 ( 5 ): 786 - 796 . DOI: 10.1016/j.gie.2024.06.002 http://dx.doi.org/10.1016/j.gie.2024.06.002 .
ANG T L , WANG L M . Rapid on-site evaluation by endoscopists: Another option to improve the diagnostic yield of EUS-FNA of solid pancreatic lesions [J]. J Gastroenterol Hepatol , 2022 , 37 ( 10 ): 1837 - 1838 . DOI: 10.1111/jgh.16002 http://dx.doi.org/10.1111/jgh.16002 .
HAN S , BHULLAR F , ALABER O , et al . Comparative diagnostic accuracy of EUS needles in solid pancreatic masses: a network meta-analysis [J]. Endosc Int Open , 2021 , 9 ( 6 ): E853 - E862 . DOI: 10.1055/a-1381-7301 http://dx.doi.org/10.1055/a-1381-7301 .
PAN Y D , RAN T J , ZHANG X D , et al . Adequacy of EUS-guided fine-needle aspiration and fine-needle biopsy for next-generation sequencing in pancreatic malignancies: a systematic review and meta-analysis [J]. Endosc Ultrasound , 2024 , 13 ( 6 ): 366 - 375 . DOI: 10.1097/eus.0000000000000097 http://dx.doi.org/10.1097/eus.0000000000000097 .
FACCIORUSSO A , ARVANITAKIS M , CRINÒ S F , et al . Endoscopic ultrasound-guided tissue sampling: European Society of Gastrointestinal Endoscopy (ESGE) technical and technology review [J]. Endoscopy , 2025 , 57 ( 4 ): 390 - 418 . DOI: 10.1055/a-2524-2596 http://dx.doi.org/10.1055/a-2524-2596 .
DHAR J , SAMANTA J , NABI Z , et al . Endoscopic ultrasound-guided pancreatic tissue sampling: lesion assessment, needles, and techniques [J]. Medicina , 2024 , 60 ( 12 ): 2021 . DOI: 10.3390/medicina60122021 http://dx.doi.org/10.3390/medicina60122021 .
OGURA T , HIJIOKA S , HARA K , et al . Multicenter, randomized controlled trial of EUS-guided fine-needle biopsy using a fork-tip needle with macroscopic or rapid on-site evaluation for pancreatic lesions (H 2 O trial) [J]. Endosc Ultrasound , 2024 , 13 ( 5 ): 300 - 305 . DOI: 10.1097/eus.0000000000000087 http://dx.doi.org/10.1097/eus.0000000000000087 .
CHEN B , LV H B , FENG Z P , et al . The role of rapid on-site evaluation in pancreatic lesion: a systematic review and meta-analysis of randomized control trials [J]. Therap Adv Gastroenterol , 2025 , 18 : 17562848251381182 . DOI: 10.1177/17562848251381182 http://dx.doi.org/10.1177/17562848251381182 .
MANGIAVILLANO B , CRINÒ S F , FACCIORUSSO A , et al . Endoscopic ultrasound-guided fine-needle biopsy with or without macroscopic on-site evaluation: a randomized controlled noninferiority trial [J]. Endoscopy , 2023 , 55 ( 2 ): 129 - 137 . DOI: 10.1055/a-1915-5263 http://dx.doi.org/10.1055/a-1915-5263 .
ALI TASNEEM A , YASEEN T , LAEEQ S M , et al . Solid pancreatic lesions: etiology, morphology and utility of macroscopic on-site evaluation in predicting good yield of endoscopic ultrasound-guided biopsy [J]. Prz Gastroenterol , 2025 , 20 ( 2 ): 192 - 198 . DOI: 10.5114/pg.2025.151850 http://dx.doi.org/10.5114/pg.2025.151850 .
IWASHITA T , YASUDA I , MUKAI T , et al . Macroscopic on-site quality evaluation of biopsy specimens to improve the diagnostic accuracy during EUS-guided FNA using a 19-gauge needle for solid lesions: a single-center prospective pilot study (MOSE study) [J]. Gastrointest Endosc , 2015 , 81 ( 1 ): 177 - 185 . DOI: 10.1016/j.gie.2014.08.040 http://dx.doi.org/10.1016/j.gie.2014.08.040 .
MASUTANI H , OKUWAKI K , KIDA M , et al . On-site stereomicroscope quality evaluations to estimate white core cutoff lengths using EUS-FNA biopsy sampling with 22-gauge needles [J]. Gastrointest Endosc , 2019 , 90 ( 6 ): 947 - 956 . DOI: 10.1016/j.gie.2019.08.033 http://dx.doi.org/10.1016/j.gie.2019.08.033 .
WATANABE M , OKUWAKI K , KIDA M , et al . Multicenter prospective study of the efficacy of stereomicroscopic on-site evaluation in endoscopic ultrasound-guided tissue acquisition in patients with pancreatic cancer [J]. Pancreatology , 2022 , 22 ( 2 ): 311 - 316 . DOI: 10.1016/j.pan.2021.12.011 http://dx.doi.org/10.1016/j.pan.2021.12.011 .
HARADA R , KATO H , FUSHIMI S , et al . A “back light system” for identification of sites for endoscopic ultrasound-guided fine-needle aspiration in solid pancreatic masses: a prospective, randomized study with a crossover design [J]. Clin Endosc , 2019 , 52 ( 4 ): 334 - 339 . DOI: 10.5946/ce.2019.004 http://dx.doi.org/10.5946/ce.2019.004 .
VAN RIET P A , GIORGIO ARCIDIACONO P , PETRONE M , et al . Combined versus single use 20 G fine-needle biopsy and 25 G fine-needle aspiration for endoscopic ultrasound-guided tissue sampling of solid gastrointestinal lesions [J]. Endoscopy , 2020 , 52 ( 1 ): 37 - 44 . DOI: 10.1055/a-0966-8755 http://dx.doi.org/10.1055/a-0966-8755 .
HUANG J L , CHENG G L , WU W , et al . Macroscopic on-site magnifier-based evaluation to estimate visible tissue core cut-off lengths using EUS-FNA with 22-gauge needles [J]. Chin Med J(Engl) , 2024 , 137 ( 4 ): 493 - 495 . DOI: 10.1097/CM9.0000000000002972 http://dx.doi.org/10.1097/CM9.0000000000002972 .
0
Views
45
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621