Efficacy of ultrasound-guided nasointestinal tube placement technique based on the "R-S-A" 3-point positioning in critically ill patients
To evaluate the precision and effectiveness of ultrasound-guided visualization for nasojejunal tube placement with the "R(right reclining)-S(shoulder)-A(abdominal)" 3-point positioning for critically ill patients.
Methods
2
A retrospective analysis was conducted on all critically ill patients who underwent nasojejunal tube placement in Department of Critical Medicine of a tertiary hospital in Chongqing from April 2022 to August 2023. According to the position of the catheter
they were divided into a control group and an observation group. The control group received ultrasound-guided nasojejunal tube insertion
while the observation group used the "R-S-A" 3-point positioning (the patient were placed in a right lateral position
the nurse stood at the right shoulder of the patient
and the ultrasound operator stood on the right side of the abdomen in the operating direction) for ultrasound-guided nasojejunal tube insertion. And
the control group had no specific requirements for positioning during the procedure. After propensity matching
the time and success rate of catheter insertion and incidence of complications were compared between the 2 groups.
Results
2
The time of catheter insertion was significantly shorter (36.2±10.3
vs
42.3±8.3 min)
and the success rate of insertion was obviously higher (95.2%
vs
66.7%) in the observation group when compared with the control group (
P
<
0.05). The incidence of complication was 9.5% in the observation group
and
28.6% in the control group
but there was no statistical difference between the 2 groups.
Conclusion
2
Ultrasound-guided nasojejunal tube placement based on "R-S-A" 3-point positioning has high precision and strong effectiveness in critically ill patients
which can shorten the time and improve the success rate of catheter insertion.
DU J, WANG H, HE M, et al . Effect of individualized nutritional support treatment based on nutritional risk assessment on nutritional status and prognosis of critically ill patients[J ] . J Guangxi Med Univ, 2019, 36(9): 1518-1522. DOI: 10.16190/j.cnki.45-1211/r.2019.09.030.
West China Evidence-Based Nursing Center of Sichuan University, Nursing Management Committee of Chinese Nursing Association, Neurosurgery Branch of Chinese Medical Association. Nursing practice guideline for enteral nutrition in patients with stroke[J]. Chin J Evid-Based Med, 2021, 21(06): 628-641. DOI: 10.7507/1672-2531.202101115
JIANG L B, LI R J, LIU L L, et al . Clinical practice guide of early enteral nutrition for critically ill patients of European intensive care medical association[J ] . Chin J Emerg Med, 2017, 26(3): 270-271. DOI: 10.3760/cma.j.issn.1671-0282.2017.03.007.
DAVIES A R, FROOMES P R A, FRENCH C J, et al . Randomized comparison of nasojejunal and nasogastric feeding in critically ill patients[J ] . Crit Care Med, 2002, 30(3): 586-590. DOI: 10.1097/00003246-200203000-00016.
ZHENG Y H, WANG M X, XU F Y, et al . Nursing care on methods and complication of inserting nasal-intestinal tube for critically elderly patients[J ] . J Nurs Rehabil, 2018, 17(5): 31-33. DOI: 10.3969/j.issn.1671-9875.2018.05.010.
SUN B R, ZHANG C, SHEN C Y, et al . Real-time ultrasound-assisted combined with intermittent water and gas injection in nasojejunal tube insertion in critically ill patients[J ] . Parenter Enter Nutr, 2020, 27(4): 199-204. DOI : 10.16151/j.1007-810x.2020.04.003.
ZHU R, XU F L, FU H, et al . The effect of ultrasound-assisted spiral nasointestinal tube placem ent on stress response and hemodynamics in patients with severe trauma[J ] . Parenter Enter Nutr, 2019, 26(5): 281-285. DOI: 10.16151/j.1007-810x.2019.05.006.
XU C, HUANG Z W, JIANG H Y, et al . Localization of pylorus under the guidance of bedside ultrasound and its clinical application in nasal-jejunum intubation for critical patients[J ] . Acta Anat Sin, 2017, 48(4): 440-444. DOI: 10.16098/j.issn.0529-1356.2017.04.012.
LENG Q, HU D, WU X H, et al . Application effect of improved "three-step" blind naso-intestinal tube insertion in critically ill patients[J ] . Mod Nurse, 2021, 28(3): 114-116. DOI: 10.19793/j.cnki.1006-6411.2021.09.045.
LIANG J L, LI M Y, LIU D H, et al . Application of improved posture combined with auscultation positioning in nasointestinal tube placement in critically ill patients[J ] . Electron J Pract Clin Nurs Sci, 2019, 4(19): 156, 158.
CHEN Q B, WANG W P, ZHOU P P, et al . Application efficacy of indwelling nasojejunal tube in senile dementia patients under different postures[J ] . China Mod Dr, 2021, 59(15): 179-182.
JIA X Y. Study on the effect of stomach-pushing manipulation combined with ultrasound on nasojejunal intubation in patients with severe neurological diseases[D]. Changchun: Jilin University, 2023.
LI C L, HUANG W H. Application of gas injection combined with pen holding blind nasojejunostomy tube insertion in critically ill patients[J]. Jilin Med J, 2023, 44(5): 1369-1371. DOI: 10.3969/j.issn.1004-0412.2023.05.074.
SUN J H, LI X, ZHAO M X, et al . Application of ultrasound combined with abdominal palpation in nasojejunal feeding tube placement[J ] . J Nurses Train, 2022, 37(20): 1834-1837, 1856. DOI: 10.16821/j.cnki.hsjx.2022.20.003.
Professional Committee of Nasoenteric Nursing Technology of Guangdong NursingSociety. Expert consensus on ultrasound-guided nasoenteric intubation in adults[J]. Mod Clin Nurs, 2022, 21(10): 1-6. DOI: 10.3969/j.issn.1671-8283.2022.10.001.
Safe and effective concentration of ropivacaine in interscalene brachial plexus block for children aged 6 to 10 years: a sequential allocation study
A case series report of extracorporeal membrane oxygenation support for inter-hospital transport to critically ill patients
Efficacy of ultrasound-guided versus body surface localization on scalp nerve block in awake craniotomy: report of 82 cases
Safety of ultrasound-guided deep vein catheterization in uremic patients with heart failure under unconventional body positions: report of 148 cases
Related Author
YANG Li
YANG Fei
TIAN Yaqiong
LIU Ling
GAO Wen
SHI Yuan
TU Shengfen
LI Shangyingying
Related Institution
Department of Anesthesiology Children’s Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Child Neurodevelopment and Cognitive Disorders
Department of Thoracic Surgery, First Affiliated Hospital, Army Medical University (Third Military Medical University)
Department of Cardiac Surgery, First Affiliated Hospital, Army Medical University (Third Military Medical University)
Department of Anesthesiology, the First Affiliated Hospital of Chongqing Medical University
Department of Anesthesiology, the Second Affiliated Hospital of Chongqing Medical University