Zixuan LI, Yibing FANG, Wei CHENG. Establishment and stability assessment of mouse cervical heterotopic heart transplantation model with "Anchoring Node"[J]. Journal of Army Medical University, 2024, 46(8): 822-828.
DOI:
Zixuan LI, Yibing FANG, Wei CHENG. Establishment and stability assessment of mouse cervical heterotopic heart transplantation model with "Anchoring Node"[J]. Journal of Army Medical University, 2024, 46(8): 822-828. DOI: 10.16016/j.2097-0927.202312083.
Establishment and stability assessment of mouse cervical heterotopic heart transplantation model with "Anchoring Node"
① 实验组共进行25只移植,失败2只,供心存活率92%;对照组共进行25只移植,失败8只,供心存活率68%。实验组动脉平均外翻1.16次,修剪0.04次;静脉平均外翻1.16次,修剪0.04次。对照组动脉平均外翻2.00次,修剪0.21次;静脉平均外翻2.28次,修剪0.46次。②实验组、对照组的颈部心脏移植总时间[(77.22±3.82)
To optimize the operational steps and processes in mouse cervical heterotopic heart transplantation by modifying the conventional cuff technique for vascular anastomosis and consequently establish a more stable cervical heterotopic heart transplantation model in mice.
Methods
2
C57BL/6 male mice (6~8 weeks old
weighing 20~24 g) were categorized into control (conventional cuff technique) and experimental groups (our "Anchoring Node" technique). Time for each surgical step
frequencies of vascular everting and vascular trimming
and the reasons for failure were recorded and compared between the 2 groups. Postoperative survival of heart allograft was determined by daily observation and touching
and the mice with the survival time >48 h were considered as successful model establishment. On the 7th and 14th days after surgery
HE staining was used to observe the pathologic changes in the vascular tissues at anastomosis. The expression of troponin T (cTnT) in the heart on the 7th day was detected with immunofluorescence assay.
Results
2
① In the 25 hearts from each group
2 hearts from the experimental group and 8 from the control group failed
and the survival rate of heart allografts was 92% and 68%
respectively. In the experimental group
arterial and venous everting occurred at an average of 1.16 times
with an average frequency of trimming of 0.04 times
while in the control group
arterial and venous everting was 2.00 and 2.28 times
respectively
with an average frequency of trimming of 0.21 and 0.46 times
respectively. ② Significant differences were observed in the overall duration for cervical heterotopic heart transplantation (77.22±3.82
vs
87.49±8.01 min)
vascular separation plus cannulation (30.06±2.68
vs
36.50±6.67 min)
and cervical anastomosis (7.31±1.08
vs
12.34±2.58 min) between the experimental and control groups (all
P
<
0.05). ③HE staining displayed that vascular patency was observed in the experimental group on the 7th and 14th days after surgery. ④cTnT staining indicated no massive myocardial necrosis was seen in both groups.
Conclusion
2
Based on conventional cuff technique for mouse cervical heterotopic heart transplantation
our modified "Anchoring Node" technique ensures the stability and efficiency of one-man microscopic operation with controllable quality
with the advantages of longer postoperative survival of heart allograft
high patency rate of anastomotic vessels
good cardiac function
and fewer postoperative complications.
关键词
Keywords
references
LI W J, SHEPHERD H M, KRUPNICK A S, et al . Mouse heterotopic cervical cardiac transplantation utilizing vascular cuffs[J ] . J Vis Exp, 2022(184): 10.3791/64089. DOI: 10.3791/64089.
LI C, QI F, LIU T, et al . Improved cuff technique for establishing a mouse-rat heterotopic cardiac xenotransplan-tation model[J ] . Transplant Proc, 2015, 47(6): 2026-2031. DOI: 10.1016/j.transproceed.2015.02.028.
HE Y, GONG N Q. Construction of animal model of heart transplantation[J]. Pract J Organ Transplant Electron Version, 2016, 4(2): 88-92. DOI: 10.3969/j.issn.2095-5332.2016.02.008.
LIU Y W, YANG P J, WEI Q Y. Preliminary exploration of mouse cervical heterotopic heart transplantation model[J]. J Med Res, 2023, 52(2): 71-75. DOI: 10.11969/j.issn.1673-548X.2023.02.014.
CORRY R J, WINN H J, RUSSELL P S. Primarily vascularized allografts of hearts in mice[J]. Transplantation, 1973, 16(4): 343-350. DOI: 10.1097/00007890-197310000-00010.
SONG S H, XU C Y, GUO M, et al . Establishment and improvement of abdominal heterotopic heart transplantation model in mice[J ] . Acad J Second Mil Med Univ, 2018, 39(3): 280-284. DOI: 10.16781/j.0258-879x.2018.03.0280.
LI H, KONG G C, ZHUANG Q, et al . Improve the procedure of heart transplantation in mice and summarize the previous experience[J ] . Chin J Transplant Electron Ed, 2018, 12(1): 34-38. DOI: 10.3877/cma.j.issn.1674-3903.2018.01.008.
LIU F C, KANG S M. Heterotopic heart transplantation in mice[J]. J Vis Exp, 2007(6): 238. DOI: 10.3791/238.
CHEN Z H. A technique of cervical heterotopic heart transplantation in mice[J]. Transplantation, 1991, 52(6): 1099-1101. DOI: 10.1097/00007890-199112000-00035.
RATSCHILLER T, DEUTSCH M A, CALZADA-WACK J, et al . Heterotopic cervical heart transplantation in mice[J ] . J Vis Exp, 2015(102): e52907. DOI: 10.3791/52907.
MATSUURA A, ABE T, YASUURA K. Simplified mouse cervical heart transplantation using a cuff technique[J]. Transplantation, 1991, 51(4): 896-898. DOI: 10.1097/00007890-199104000-00031.
MAO X, XIAN P, YOU H, et al . A modified cuff technique for mouse cervical heterotopic heart transplantation model[J ] . J Vis Exp, 2022(180). DOI: 10.3791/63504.
FUKUNAGA N, BISSOONDATH V, RAO V. Submandibular gland-preserving technique for heterotopic cervical heart transplantation in mice[J]. Transplantation, 2018, 102(11): e464-e465. DOI: 10.1097/TP.0000000000002395.
MA Y H, XIE B Y, DAI H L, et al . Optimization of the cuff technique for murine heart transplantation[J ] . J Vis Exp, 2020(160). DOI: 10.3791/61103.
OBERHUBER R, CARDINI B, KOFLER M, et al . Murine cervical heart transplantation model using a modified cuff technique[J ] . J Vis Exp, 2014(92): e50753. DOI: 10.3791/50753.
TAN L, XIE X B, XU Y N, et al . Skills to perform vessel eversion in mouse cervical cardiac transplantation with cuff technique[J ] . Braz J Cardiovasc Surg, 2021, 36(3): 318-322. DOI: 10.21470/1678-9741-2020-0125.
PLENTER R J, ZAMORA M R, GRAZIA T J. Four decades of vascularized heterotopic cardiac transplantation in the mouse[J]. J Invest Surg, 2013, 26(4): 223-228. DOI: 10.3109/08941939.2012.755238.
TOMITA Y, ZHANG Q W, YOSHIKAWA M, et al . Improved technique of heterotopic cervical heart transplantation in mice[J ] . Transplantation, 1997, 64(11): 1598-1601. DOI: 10.1097/00007890-199712150-00017.
WANG Q X, LIU Y S, LI X K. Simplified technique for heterotopic vascularized cervical heart transplantation in mice[J]. Microsurgery, 2005, 25(1): 76-79. DOI: 10.1002/micr.20082.
FUKUNAGA N, BISSOONDATH V, RAO V. Custom-made clamp facilitating stabilization of cuffs in murine heterotopic cervical heart transplantation[J]. Transplantation, 2019, 103(4): e62-e63. DOI: 10.1097/TP.0000000000002582.