Fang LI, Xingwu ZHONG, Jun YANG, et al. Corneal visualization Scheimpflug technology evaluates corneal biomechanical properties in children with different refractive states[J]. Journal of Third Military Medical University, 2021, 43(8): 766-771.
DOI:
Fang LI, Xingwu ZHONG, Jun YANG, et al. Corneal visualization Scheimpflug technology evaluates corneal biomechanical properties in children with different refractive states[J]. Journal of Third Military Medical University, 2021, 43(8): 766-771. DOI: 10.16016/j.1000-5404.202010102.
Corneal visualization Scheimpflug technology evaluates corneal biomechanical properties in children with different refractive states
To evaluate the corneal biomechanical parameters in myopic
hypermetropic and emmetropic eyes using corneal visualization Scheimpflug technology (CorVis ST).
Methods
2
A total of 123 children having 191 myopic
hypermetropic and emmetropic eyes admitted to our hospital from August 2019 to January 2020 were enrolled in this study. Corneal biomechanical parameters
axial length (AL) and corneal curvature were measured using CorVis ST and Lenstar 900 respectively. Univariate linear correlation analysis and multivariate linear regression analysis were used to assess the impacts of age
spherical equivalent (SE)
AL
central corneal thickness (CCT) and mean corneal curvature on corneal biomechanical parameters.
Results
2
Multivariate linear regression analysis indicated that SE was positively correlated with time at first applanation (A1T
P
=0.004); AL was positively correlated with A1T (
P
=0.017) and radius of reverse curvature at the time of highest concavity (HCR
P
=0.02)
but negatively with deformation amplitude at second applanation (A2DA
P
<
0.001); CCT was positively correlated with length at first applanation (A1L
P
<
0.001)
A1DA (
P
=0.005)
time of highest concavity (
P
=0.004)
but negatively with A1T (
P
=0.041).
Conclusion
2
The biomechanical parameters of children may be related with their refractive states. Higher myopic eyes tend to have lower corneal elasticity.
关键词
Keywords
references
BUENO-GIMENO I, ESPAÑA-GREGORI E, GENE-SAMPEDRO A, et al . Relationship among corneal biomechanics, refractive error, and axial length[J ] . Optom Vis Sci, 2014, 91(5): 507-513. DOI: 10.1097/OPX.0000000000000231.
DEL BUEY M A, LAVILLA L, ASCASO F J, et al . Assessment of corneal biomechanical properties and intraocular pressure in myopic Spanish healthy population[J ] . J Ophthalmol, 2014, 2014: 905129. DOI: 10.1155/2014/905129.
WANG W, HE M, HE H, et al . Corneal biomechanical metrics of healthy Chinese adults using Corvis ST[J ] . Cont Lens Anterior Eye, 2017, 40(2): 97-103. DOI: 10.1016/j.clae.2016.12.003.
NEMETH G, HASSAN Z, CSUTAK A, et al . Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas[J ] . J Refract Surg, 2013, 29(8): 558-563. DOI: 10.3928/1081597x-20130719-06.
HON Y, LAM A K C. Corneal deformation measurement using scheimpflug noncontact tonometry[J]. Optom Vis Sci, 2013, 90(1): e1-e8. DOI: 10.1097/opx.0b013e3182 79eb87.
WU Y, TIAN L, HUANG Y F, et al . In vivo corneal biomechanical properties with corneal visualization scheimpflug technology in Chinese population[J ] . Biomed Res Int, 2016, 2016: 7840284. DOI: 10.1155/2016/7840284..
ASAOKA R, N AKAKURA S, TABUCHI H, et al . The relationship between corvis ST tonometry measured corneal parameters and intraocular pressure, corneal thickness and corneal curvature[J ] . PLoS ONE, 2015, 10(10): e0140385. DOI: 10.1371/journal.pone.0140385.
WANG J Y, LI Y, JIN Y M, et al . Corneal biomechanical properties in myopic eyes measured by a dynamic scheimpflug analyzer[J ] . J Ophthalmol, 2015, 2015: 161869. DOI: 10.1155/2015/161869.
LEE R, CHANG R T, WONG I Y, et al . Assessment of corneal biomechanical parameters in myopes and emmetropes using the Corvis ST[J ] . Clin Exp Optom, 2016, 99(2): 157-162. DOI: 10.1111/cxo.12341.
HE M, DING H, HE H, et al . Corneal biomechanical properties in healthy children measured by corneal visualization scheimpflug technology[J ] . BMC Ophthalmol, 2017, 17(1): 70. DOI: 10.1186/s12886-017-0463-x.
WU W J, DOU R, WANG Y. Comparison of corneal biomechanics between low and high myopic eyes—A meta-analysis[J]. AmJ Ophthalmol, 2019, 207: 419-425. DOI: 10.1016/j.ajo.2019.07.007.
BUENO-GIMENO I, ESPAÑA-GREGORI E, GENE-SAMPEDRO A, et al . Relationship among corneal biomechanics, refractive error, and axial length[J ] . Optom Vis Sci, 2014, 91(5): 507-513. DOI: 10.1097/OPX.0000 000000000231.
NEMETH G, SZALAI E, HASSAN Z, et al . Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas[J ] . Int J Ophthalmol, 2017, 10(2): 217-222. DOI: 10.18240/ijo.2017.02.06.
ZHANG Y H, WANG Y, LI L Y, et al . Corneal stiffness and its relationship with other corneal biomechanical and nonbiomechanical parameters in myopic eyes of Chinese patients[J ] . Cornea, 2018, 37(7): 881-885. DOI: 10.1097/ICO.0000000000001605.
ELSHEIKH A, GERAGHTY B, RAMA P, et al . Characterization of age-related variation in corneal biomechanical properties[J ] . J R Soc Interface, 2010, 7(51): 1475-1485. DOI: 10.1098/rsif.2010.0108.