Anatomic influencing factors on implantation depth of self-expandable valve and its short-term clinical outcome: a retrospective cohort study of 54 cases
Clinical Medicine|更新时间:2026-01-09
|
Anatomic influencing factors on implantation depth of self-expandable valve and its short-term clinical outcome: a retrospective cohort study of 54 cases
Journal of Third Military Medical UniversityVol. 43, Issue 4, Pages: 329-334(2021)
Yong WANG, Chen ZHANG, Ting LIU, et al. Anatomic influencing factors on implantation depth of self-expandable valve and its short-term clinical outcome: a retrospective cohort study of 54 cases[J]. Journal of Third Military Medical University, 2021, 43(4): 329-334.
DOI:
Yong WANG, Chen ZHANG, Ting LIU, et al. Anatomic influencing factors on implantation depth of self-expandable valve and its short-term clinical outcome: a retrospective cohort study of 54 cases[J]. Journal of Third Military Medical University, 2021, 43(4): 329-334. DOI: 10.16016/j.1000-5404.202009141.
Anatomic influencing factors on implantation depth of self-expandable valve and its short-term clinical outcome: a retrospective cohort study of 54 cases
To investigate the anatomic factors influencing the implantation depth (ID) of self-expandable valve during transcatheter aortic valve replacement (TAVR) surgery
and to analyze the impact of ID on the short-term clinical prognosis.
Methods
2
Clinical data of 54 patients with severe aortic stenosis who underwent TAVR in our hospital from October 2017 to May 2020 were collected and retrospectively analyzed. The anatomic diameter of aortic root and its ratio to the implanted valve size was measured and calculated
and the depth of the valve implanted was also measured. The patients were assigned into either over-implanted group (>14.8 mm
the highest quartile of ID) or well-implanted group (≤14.8 mm) based on the ID of their valve. The differentiation of anatomical structures was compared between the 2 groups. Additionally
the impacts of ID on the clinical outcomes such as hemodynamics and conduction block were analyzed.
Results
2
There were 21 cases of bicuspid aortic valve (BAV) and 33 cases of tricuspid aortic valve (TAV)
and the ID of valve was 0~21 mm
with a median of 11.6 mm. Among the BAV pat
ients
the average diameter of sinotubular junction (STJ) was significantly larger in the over-implanted group than the well-implanted group (36.06±2.29
vs
29.69±2.55 mm
P
=0.001). As for the TAV patients
the over-implanted group had a higher proportion of large prosthesis implantation (100.0%
vs
26.9%
P
=0.025)
and a smaller ratio of the length of the left ventricular output tract to the bottom diameter of the valve (0.99±0.03
vs
1.12±0.15
P
=0.021) when compared with the well-implanted group. Postoperative mortality was comparable between the 2 groups (4.88%
vs
15.38%
P
=0.242). However
the incidence of being converted to open surgery was higher in the over-implanted group than the other group (15.4%
vs
0%
P
=0.055). In 1 week after TAVR
there were no statistical differences in the mean aortic valve gradient
maximum velocity
permanent pacemaker implantation rate
moderate or severe paravalvular leakage
or new-onset left bundle branch block (LBBB) between the 2 groups (
P
>
0.05)
whereas the incidence of new-onset LBBB (50.0%
vs
13.3%
P
=0.044) and paravalvular leakage (33.3%
vs
0%
P
=0.009) were higher in the over-implanted group on the 30th day. The early safety was inferior in the over-implanted group (69.2%
vs
95.1%
P
=0.025).
Conclusion
2
The anatomical structure of the aortic root and its ratio to the size of the implanted valve have a certain effect on the implantation depth of self-expandable prosthesis. The BAVs patients with greater STJ as well as those TAVs patients treated with larger size valve may be both correlated with increased risks of deep implantation. Over implantation of the valve may increase the risk of new-onset LBBB and moderate or severe paravalvular leakage in 1 month after operation
Professional Committee of Structural Cardiology of Cardiovascular Physicians Branch, Chinese Medical Doctor Association. Chinese expert consensus on transcatheter aortic valve Replacement (2020 Update)[J]. Chin J Intervent Cardiol, 2020, 28 (6): 301-309. DOI: 10.3969/j.issn.1004-8812.2020.06.001.
CHEN Y H. Does valve implantation depth defined by pre-release angiogram reflect the final depth in TAVR?[J]. JACC Cardiovasc Interv, 2019, 12(23): 2435-2436. DOI: 10.1016/j.jcin.2019.09.026.
PETRONIO A S, SINNING J M, VAN MIEGHEM N, et al . Optimal implantation depth and adherence to guidelines on permanent pacing to improvethe results of transcatheter aortic valve replacement with the medtronic CoreValve system: the CoreValve prospective, international, post-market ADVANCE-Ⅱ study[J ] . JACC Cardiovasc Interv, 2015, 8(6): 837-846. DOI: 10.1016/j.jcin.2015.02.005.
PIAYDA K, HELLHAMMER K, VEULEMANS V, et al . Navigating the "optimal implantation depth" with a self-expandable TAVR device in daily clinical practice[J ] . JACC Cardiovasc Interv, 2020, 13(6): 679-688. DOI: 10.1016/j.jcin.2019.07.048.
VAN BELLE E, DELHAYE C, VINCENT F. The mirage of the optimal implantation depth with transcatheter bioprosthesis[J]. JACC Cardiovasc Interv, 2020, 13(6): 689-692. DOI: 10.1016/j.jcin.2019.10.035.
WANG M Y, SONG Y G, WANG Y, et al . Impact of aortic root morphology on the implantation depth of aortic valve prosthesis during trans-catheter aortic valve replacement in patients with native bicuspid aortic valve[J ] . Chin J Cardiol, 2018, 46(8): 629-634. DOI:10.3760/cma.j.issn.0253-3758.2018.08.010.
ELFAQUIR N, DEBACKER O, BOSMANS J, et al . Patient-specific computer simulation in TAVR with the self-expanding evolut R valve[J ] . JACC Cardiovasc Interv, 2020, 13(15): 1803-1812. DOI: 10.1016/j.jcin.2020.04.018.
WANG Y, ZHANG C, LIU T, et al .Analysis of characteristics and cardiac anatomy of patients with conduction block after transcatheter aortic valve replacement with Venus-A valve[J ] . West China Med J, 2020, 35(9): 1044-1049. DOI: 10.7507/1002-0179.202008011.
JILAIHAWI H, CHEN M, WEBB J, et al . A bicuspid aortic valve imaging classification for the TAVR era[J ] . JACC Cardiovasc Imaging, 2016, 9(10): 1145-1158. DOI: 10.1016/j.jcmg.2015.12.022.
KAPPETEIN A P, HEAD S J, GÉNÉREUX P, et al . Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document[J ] . Eur Heart J, 2012, 33(19): 2403-2418. DOI: 10.1093/eurheartj/ehs255.
XIONG T Y, LI Y J, FENG Y, et al . Understanding the interaction between transcatheter aortic valve prostheses and supra-annular structures from post-implant stent geometry[J ] . JACC Cardiovasc Interv, 2019, 12(12): 1164-1171. DOI: 10.1016/j.jcin.2019.02.051.
LIU Q R, LYU S L, WU Y J. Design features of Venus A-Valve artificial aortic valve made in China[J]. Chin J Med, 2015, 50(1): 9-10.
VAN GILS L, WÖHRLE J, HILDICK-SMITH D, et al . Importance of contrast aortography with Lotus transcatheter aortic valve replacement: a post hoc analysis from the RESPOND post-market study[J ] . JACC Cardiovasc Interv, 2018, 11(2): 119-128. DOI: 10.1016/j.jcin.2017.10.016.
LIAO Y B, ZHAO Z G, WEI X, et al . Transcatheter aortic valve implantation with the self-expandable Venus A-Valve and CoreValve devices: Preliminary experiences in China[J ] . Catheter Cardiovasc Interv, 2017, 89(s1): 528-533. DOI: 10.1002/ccd.26912.
Working Group of Structural Heart Diseases of Branch of Cardiovascular Disease of Chinese Medical Association. Expert recommendation on the transcatheter aortic valve replacement for bicuspid aortic[J]. Chin J Cardiol, 2020, 48(8): 634-640.
Influence of early left ventricular end-diastolic diameter improvement on prognosis of severe aortic valve stenosis patients after transcatheter aortic valve replacement
A novel estrogen receptor expression stratification (low/moderate/high) based on Chinese population provides more accurate prognosis prediction for HR+/HER2- early breast cancer patients
Immunosuppressive microenvironment of TGIF1-overexpressing gastric cancers and its clinical significance
Impact of molecular heterogeneity of NPM1 mutations on prognosis of acute myeloid leukemia: a clinical report of 86 cases
Association of 5-factor modified frailty index and controlling nutritional status score with overall survival in patients with unresectable hepatocellular carcinoma undergoing interventional therapy
Related Author
胡美玲
王勇
刘婷
李春
曾颖
胡金蓉
王颖
钱德慧
Related Institution
Department of Breast and Thyroid Surgery, First Affiliated Hospital, Army Medical University (Third Military Medical University)
Department of Gastroenterology, Chongqing Hechuan District People’s Hospital
School of Medicine, Chongqing University
Chongqing Key Laboratory of Precision Prevention and Treatment for Digestive System Tumors, Department of Gastroenterology, Army Medical Center of PLA/Daping Hospital of Third Military Medical University
Department of Hematology, the First Hospital of Lanzhou University