Tengyun GUO, Rui XU, Guojing LIU, et al. Efficacy of Complex coils in embolization of intracranial lobulated aneurysms: a clinical analysis of 34 cases[J]. Journal of Third Military Medical University, 2019, 41(17): 1677-1681.
DOI:
Tengyun GUO, Rui XU, Guojing LIU, et al. Efficacy of Complex coils in embolization of intracranial lobulated aneurysms: a clinical analysis of 34 cases[J]. Journal of Third Military Medical University, 2019, 41(17): 1677-1681. DOI: 10.16016/j.1000-5404.201903169.
Efficacy of Complex coils in embolization of intracranial lobulated aneurysms: a clinical analysis of 34 cases
To evaluate the efficacy of Complex coils as the framing coils on the embolization of intracranial lobulated aneurysms.
Methods
2
From April 2017 to April 2018
34 patients with lobulated aneurysms admitted in our neurosurgery department were enrolled in this study. They all underwent implantation of Complex coils as the framing coils
and their clinical data were collected and retrospectively analyzed. The results of intraoperative cerebral angiography and follow-up outcomes were discussed.
Results
2
According to the Raymond standard of aneurysm occlusion
grade Ⅰ occurred in 27 of 34 patients (79.4%)
and grade Ⅱ in 5 patients (14.7%)
in intraoperative assessment. In the 31 patients who were followed-up through digital subtraction angiography at 6 months after operation
no recurrence was found. In the assessment of aneurysm occlusion
Raymond grade Ⅰ was achieved in 28 patients (90.3%)
and Raymond grade Ⅱ in 3 patients (9.7%). No complications associated with Complex coils were observed during perioperative period.
Conclusion
2
Complex coils achieves a high success rate as forming frame in the embolization of lobulated aneurysms
with no obvious increase in complications.
关键词
Keywords
references
ZHANG X G, ZHONG J J, GAO H, et al . Endovascular treatment of intra cranial aneurysms with the LVIS device: A systematic review[J ] . J Neurointerv Surg, 2017, 9(6): 553- 557. DOI:10.1136/neurintsurg-2016-012403.
MOLYNEUX A, KERR R, INTERNATIONAL SUBARACHNOID ANEURYSM TRIAL (ISAT) COLLABORATIVE GROUP, et al . International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms: A randomized trial[J ] . J Stroke Cerebrovasc Dis, 2002, 11(6): 304-314. DOI:10.1053/jscd.2002.130390.
MOLYNEUX A J, KERR R S, YU L M, et al . International Subarachnoid Aneurysm Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2 143 patients with ruptured intracranial aneurysms: A randomised comparison of effects on survival, dependency, seizures, rebleeding, subgroups, and aneurysm occlusion[J ] . Lancet, 2005, 366(9488): 809-817. DOI:10.1016/S0140-6736(05)67214-5.
GOERTZ L, KASUYA H, HAMISCH C, et al . Impact of aneurysm shape on morbidity after clipping of unruptured intracranial aneurysms[J ] . Acta Neurochir (Wien), 2018, 160(11): 2169-2176. DOI:10.1007/s00701-018-3675-9.
JIANG Y X, JI X, CHENG Y, et al . Embolization of internal carotid artery anterior wall aneurysms by stenting and coiling: 8 cases with "rivets" technology[J ] . J Third Mily Med Univ, 2019, 41(4): 360-365. DOI:10.16016/j.1000-5404.201809081.
PENG T M, HUANG C R, JIANG Y, et al . Is single low-profile visualized intraluminal support (LVIS)-assisted coiling of wide-necked ruptured multiple intracranial aneurysms in one stage feasible?[J ] . World Neurosurg, 2018, 118: e388-e394. DOI:10.1016/j.wneu.2018.06.200.
ZHANG Y, YANG X J, MU S Q, et al . Analysis of hemodynamic numerical simulation of lobulated intracranial aneurysms[J ] . Chin J Cerebrovascul Dis, 2009, 6(6): 293-297. DOI:10.3969/j.issn.1672-5921.2009.06.005.
PENTIMALLI L, MODESTI A, VIGNATI A, et al . Role of apoptosis in intracranial aneurysm rupture[J ] . J Neurosurg, 2004, 101(6): 1018-1025. DOI:10.3171/jns.2004.101.6.1018.
LI X X, KATO Y, QIU Y M, et al . Analysis of size, aspect ratio and configuration in ruptured aneurysms[J ] . J Shanghai Jiaotong Univ (Med Sci), 2007, 27(3): 265-267.
ZHANG M H, PENG T M, LI L, et al . Risk factors and prognostic analysis of rerupture in the embolization of ruptured intracranial aneurysms[J ] . Chin J Neurosurg, 2016, 32(11): 1131-1134. DOI:10.3760/cma.j.issn.1001-2346.2016.11.013.
LI L, ZHANG X X, FENG Z Z, et al . Risk factors for intraprocedural rupture in the endovascular treatment of unruptured intracranial aneurysms: A single-center experience with 1232 procedures[J ] . World Neurosurg, 2019, 123: e9-e14. DOI:10.1016/j.wneu.2018.09.164.
LEI T, ZHAO Z W, MA X Y, et al . Causes and protection of intracranial aneurysms uncompletely embolized with micro-coils[J ] . J Pract Radiol, 2006, 22(4): 443-445. DOI:10.3969/j.issn.1002-1671.2006.04.018.
XU X, ZHENG Y, WANG D Y, et al .Clinical application of versatile fill coils to endovascular treatment of irregular intracranial aneurysm[J ] . Chin J Neurosurg, 2017, 33(1): 41-44. DOI: 10.3760/cma.j.issn.1001-2346.2017.01.011.
YIN L, WEI M, REN H C. Double microcatheter technique for coil embolization of small aneurysms with unfavorable configurations: A comparative study of the aneurysms that are ≤3 mm or>3 mm[J]. Interv Neuroradiol, 2016, 22(2): 158-164. DOI:10.1177/1591019915622166.
YANG S, XU Z J, YANG Y W, et al . Application of double microcatheter in the intervened embolism of lobulated arterial aneurysm[J ] . Chin J Neurosurgl Dis Res, 2018, 17(5): 403-405.
ZHU Q F, WANG G F, ZHOU Z G, et al .Clinical experience of endovascular treatment for ruptured and lobulated intracranial aneurysms[J ] . Chin J Neuromed, 2013, 12(11): 1168-1170. DOI: 10.3760/cma.j.issn.1671-8925.2013.11.019.
ZHANG Y, GAO G, CHAO Y J, et al . Endovascular treatment of irregular and complicated intracranial aneurysms with coils using double microcatheter technique[J ] . Exp Ther Med, 2017, 13(1): 75-78. DOI:10.3892/etm.2016.3960.
DHOLAKIA R J, KAPPEL A D, PAGANO A, et al . In vitro angiographic comparison of the flow-diversion performance of five neurovascular stents[J ] . Interv Neuroradiol, 2018, 24(2): 150-161. DOI: 10.1177/15910199177 48317..
LYU N, ZHOU Y, YANG P F, et al . Flow diverters in treatment of complex intracranial aneurysms: a single-center experience[J ] . Acad J Second Mil Med Univ, 2019, 40(3): 304-310. DOI: 10.16781/j.0258-879x.2019.03.0304.
CAGNAZZO F, DI CARLO D T, CAPPUCCI M, et al . Acutely ruptured intracranial aneurysms treated with flow-diverter stents: a systematic review and meta-analysis[J ] . Am J Neuroradiol, 2018, 39(9): 1669-1675. DOI: 10.3174/ajnr.A5730.
Early identification of delayed cerebral ischemia following aneurysmal subarachnoid hemorrhage: development and validation of a multifactorial clinical prediction model
Risk factors for stroke-associated pneumonia after endovasular treatment in acute anterior circulation ischemic stroke patients
Efficacy of surgical clipping and endovascular treatment for middle cerebral artery aneurysms: a retrospective cohort study based on propensity score matching
Efficacy of endovascular treatment for acute ischemic stroke with large core infarction and its influencing factors
Application of AI-assisted head and neck CT angiography in diagnosis of intracranial aneurysms
Related Author
ZHENG Hui
TAO Yihao
JI Xiang
MA Ying
CAI Zhengwei
ZHANG Xiaoge
GAO Yang
ZUO Meng
Related Institution
Department of Neurosurgery, the Second Affiliated Hospital of Chongqing Medical University
Department of Neurology, First Affiliated Hospital, Army Medical University (Third Military Medical University)
Chongqing Center for Disease Control and Prevention
Department of Neurology, Daping Hospital, Army Medical University (Third Military Medical University)
Department of Neurosurgery, Fujian Provincial Hospital, Fujian Medical University Provincial Clinical Medical College