Evaluation of a time-resolved fluorescence immunochromatography for procalcitonin
Basic Medicine|更新时间:2026-01-09
|
Evaluation of a time-resolved fluorescence immunochromatography for procalcitonin
Journal of Third Military Medical UniversityVol. 41, Issue 6, Pages: 581-586(2019)
作者机构:
400037 重庆,陆军军医大学(第三军医大学)第二附属医院检验科
作者简介:
基金信息:
the Key Project of Social Welfare of Chongqing(CSTC 2015 shmszx120091);the Clinical Research Project of Xinqiao Hospital of Third Military Medical University(2015YLC29)
Dezhi HUANG, Haojun YING, Fei LIU, et al. Evaluation of a time-resolved fluorescence immunochromatography for procalcitonin[J]. Journal of Third Military Medical University, 2019, 41(6): 581-586.
DOI:
Dezhi HUANG, Haojun YING, Fei LIU, et al. Evaluation of a time-resolved fluorescence immunochromatography for procalcitonin[J]. Journal of Third Military Medical University, 2019, 41(6): 581-586. DOI: 10.16016/j.1000-5404.201810210.
Evaluation of a time-resolved fluorescence immunochromatography for procalcitonin
To evaluate the performance of a time-resolved fluorescence immunochromatographic assay for quantitative detection of procalcitonin (PCT).
Methods
2
Based on double antibody sandwich method and using time-resolved fluorescent nano-microspheres as the marker
we established an immunochromatographic assay for detecting PCT. We evaluated the performance of this method for PCT detection in terms of linearity
sensitivity
precision
specificity
and correlation.
Results
2
This immunochromatographic assay had a good linearity for PCT detection within the linear range of 0.05-100 ng/mL
and the linear equation was Y=0.074 7X+0.524 6 (
R
2
=0.990 4). The sensitivity of this method was 0.03 ng/mL with an inter-assay
precision
CV
≤5.42% and an intra-assay precision
CV
≤6.86%. The detection results by this method were well correlated with those by AE-180 automatic chemiluminescence immunoanalyzer and showed a positive coincidence rate of 96.61% and a negative coincidence rate of 94.44%; The false positive rate
false negative rate and diagnostic coincidence rate of this assay were 5.56%
3.39%
and 95.53%
respectively.
Conclusion
2
This time-resolved immunochromatographic assay allows simple
economic
rapid and quantifiable detection of PCT and shows a good performance for potential application in the detection for clinical serum samples.
关键词
Keywords
references
BOBILLO-PEREZ S, RODRÍGUEZ-FANJUL J, JORDAN GARCIA I. Is procalcitonin useful in pediatric critical care patients?[J]. Biomark Insights, 2018, 13: 117727191879 2244. DOI: 10.1177/1177271918792244.
YIN C H, WANG C, WEN Y, et al . Procalcitonin and its application in the diagnosis of sepsis[J ] . Chin J Emerg Med, 2003, 12(5): 357-358. DOI: 10.3760/j.issn:1671-0282.2003.05.036.
SHIN H J, KANG S H, MOON H S, et al . Serum procalcitonin levels can be used to differentiate between inflammatory and non-inflammatory diarrhea in acute infectious diarrhea[J ] . Medicine, 2018, 97(32): e11795. DOI: 10.1097/MD.0000000000011795.
ASSICOT M, GENDREL D, CARSIN H, et al . High serum procalcitonin concentrations in patientswith sepsis and infection[J ] . Lancet, 1993, 341(8844): 515-518. DOI: 10.1016/0140-6736(93)90277-N.
DAVIES J. Procalcitonin[J]. J Clin Pathol, 2015, 68(9): 675-679.
MUSTAFIC S, BRKIC S, PRNJAVORAC B, et al . Diagnostic and prognostic value of procalcitonin in patients with sepsis[J ] . Med Glas (Zenica), 2018, 15(2): 93-100. DOI: 10.1016/j.ijid.2008.05.1301.
Expert Consensus Group on the Emergency Clinical Application of Procalcitonin. Expert consensus on emergency clinical application of procalcitonin (PCT)[J]. Chin J Emerg Med, 2012, 21(9): 944-951. DOI: 10.3760/cma.j.issn.1671-0282.2012.09.005.
ZHU M Y, CAO E H. Detection and application of procalcitonin—interpretation for expert consensus on clinical signifcance interpretation of infection-related biomarkers[J]. Shanghai Pharmaceutical, 2018, 39(1): 14-18.
LEE T, 杨发青, 王朝南, 等.降钙素原快速定量检测试剂的研制及性能评估[J].天津科技, 2013(3): 82-84. DOI: 10.3969/j.issn.1006-8945.2013.03.034.
LEE T, YANG F Q, WANG C N, et al . Development and performance evaluation of procalcitonin quantitative rapid test kit[J ] . Tianjin Sci Technol, 2013(3): 82-84. DOI: 10.3969/j.issn.1006-8945.2013.03.034.
LI L P, YU Y, GU H F, et al . Establishment of quantitative detection method for procalcitonin by up-converting immunochromatographic assay[J ] . Chin J Lab Med, 2014, 37(2): 144-146. DOI: 10.3760/cma.j.issn.1009-9158.2014.02.017.
ZHONG Y, ZHU J, FENG H, et al . Development of immunochromatography test strips for quantitative procalcitonin detection in serum[J ] . J Nanjing Univ Technol (Nat Sci Ed), 2016, 38(4): 125-129. DOI: 10.3969/j.issn.1671-7627.2016.04.021.
LIU X W, ZHAO S. Establishment and performance evaluation of fluorescence immunochromatography for procalcitonin detection[J]. Int J Lab Med, 2017, 38(23): 3324-3326. DOI: 10.3969/j.issn.1673-4130.2017.23.039.
SHAO X, WANG C, XIE C, et al . Rapid and sensitive lateral flow immunoassay method for procalcitonin (PCT) based on time-resolved immunochromatography[J ] . Sensors, 2017, 17(3): 480. DOI: 10.3390/s17030480.
YU H, XU L, QI X P. Detection of procalcitonin in blood by quantum-dots-labeled immunochromatography[J]. Chin J Anal Chem, 2014, 42(11): 1592-1597. DOI: 10.11895/j.issn.0253-3820.140453.
QI X, HUANG Y, LIN Z, et al . Dual-quantum-dots-labeled lateral flow strip rapidly quantifies procalcitonin and C-reactive protein[J ] . Nanoscale Res Lett, 2016, 11: 167. DOI: 10.1186/s11671-016-1383-z.
HUANG X, AGUILAR Z P, XU H, et al . Membrane-based lateral flow immunochromatographic strip with nanoparticles as reporters for detection: A review[J ] . Biosens Bioelectron, 2016, 75: 166-180. DOI: 10.1016/j.bios.2015.08.032.
SHI Y M, HE H, FENG Z L, et al . Application of time-resolved fluorescence immunoassay in medical field[J ] . Int J Lab Med, 2015, 36(19): 2866-2869. DOI: 10.3969/j.issn.1673-4130.2015.19.039.
冯仁丰.临床检验质量管理技术基础[M]. 2版.上海:上海科学技术文献出版社, 2007.
FENG R F. Technical basis of clinical laboratory quality management[M]. 2nd Edition. Shanghai: Shanghai Science and Technology Literature Publishing House, 2007.
LI Y, WANG Y L. Research progress of immunochromatographic technology[J]. Chin J Health Lab Tech, 2015, 25(22): 3978-3980.
BAHADIR E B, SEZGINTVRK M K. Lateral flow assays: principles, designs and labels[J]. TrAC Trends Anal Chem, 2016, 82: 286-306. DOI: 10.1016/j.trac.2016.06.006.
HARMA H, SOUKKA T, LOVGREN T. Europium nanoparticles and time-resolved fluorescence for ultrasensitive detection of prostate-specific antigen[J]. Clin Chem, 2001, 47(3): 561-568. DOI: 10.1016/S0009-9120(01)00197-7.
LIANG R L, XU X P, LIU T C, et al . Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (Ⅲ) chelate microparticles-based lateral flow test strips[J ] . Anal Chim Acta, 2015, 891: 277-283. DOI: 10.1016/j.aca.2015.07.053.
Quantitative detection of serum pepsinogen Ⅰ by time-resolved fluorescent nanoparticle immunochromatography
Analysis of influencing factors for serum procalcitonin level in septic patients
Clinical efficacy of teicoplanin combined with L-carnitine for methicillin-resistant Staphylococcus aureus infective endocarditis
Diagnostic value of serum procalcitonin level and neutrophil percentage in prediction of spontaneous bacterial peritonitis in patients with liver disease
Diagnostic values of procalcitonin, platelet, C-reactive protein, erythrocyte sedimentation rate and white blood cell count for Kawasaki disease
Related Author
Yan ZHOU
Jun FAN
Yehua JIANG
Jue ZHANG
Yi ZHANG
Lixin FU
Biao HUANG
熊玮
Related Institution
Jiangsu Institute of Nuclear Medicine
Wuxi Jiangyuan Industrial Technology and Trade Corporation
Second Department of Cardiology, Beijing Armed Police Corps Hospital