Yibing LIU, Nannan HUANG, Zhuyu ZHANG, et al. Finite element analysis of mandibular first molar under different conditions of occlusal contact[J]. Journal of Third Military Medical University, 2018, 40(20): 1906-1910, 封3.
DOI:
Yibing LIU, Nannan HUANG, Zhuyu ZHANG, et al. Finite element analysis of mandibular first molar under different conditions of occlusal contact[J]. Journal of Third Military Medical University, 2018, 40(20): 1906-1910, 封3. DOI: 10.16016/j.1000-5404.201803209.
Finite element analysis of mandibular first molar under different conditions of occlusal contact
To establish a finite element model of the mandibular first molar and analyze the effects of different conditions of occlusal contact on stress distribution in the tooth and periodontal tissue and on tooth displacement.
Methods
2
The DICOM data of cone-beam computed tomography (CBCT) were obtained from a patient with neutral occlusion of the mandibular first molar to establish the finite element model of the mandibular first molar and the periodontal tissue. Three occlusal contact areas were defined on the occlusal surface of the first molar
namely the buccal slope at the buccal cusp (A)
lingual slope at the buccal cusp (B)
and buccal slope at the lingual cusp (C). The extreme values of stress
strain and displacement of the mandibular first molar were determined under a vertical loading of 300 N
and the impact of different conditions of occlusal contact on the dental and periodontal tissues was analyzed.
Results
2
Force loading at the occlusal contact area C resulted in the greatest peak stress
followed by simultaneous loading at a and B
and then by loading at all the 3 contacts. The stress was concentrated mostly on the lateral walls of the central fossa of the occusal surface. The variation of stress distribution in the tooth with strain loading caused displacements of the tooth
which was the greatest with force loading at C
followed sequentially by loading at A
BC
AB
and B
and was the smallest with loading at AC and ABC.
Conclusions
2
Occlusal contact at a or C exclusively can be detrimental to maintaining the tooth contact stability and should be avoided
and occlusal adjustment to allow multiple occlusal contacts helps to disperse the occlusal stress.
关键词
Keywords
references
STONE J C, HANNAH A, NAGAR N. Dental occlusion and temporomandibular disorders[J]. Evid Based Dent, 2017, 18(3): 86-87. DOI: 10.1038/sj.ebd.6401258.
RIBEIRO A A, AZCARATE-PERIL M A, CADENAS M B, et al. The oral bacterial microbiome of occlusal surfaces in children and its association with diet and caries[J]. PLoS ONE, 2017, 12(7): e0180621. DOI: 10.1371/journal.pone.0180621.
易新竹.牙合学[M]. 2版.北京:人民卫生出版社, 2008: 10.
YI X Z. Gnathology[M]. 2nd Ed. Beijing: People's Medical Publishing House, 2008: 10.
MACDONALD J W, HANNAM A G. Relationship between occlusal contacts and jaw-closing muscle activity during tooth clenching: Part Ⅱ[J]. J Prosthet Dent, 1984, 52(6): 862-867. DOI: 10.1016/0022-3913(84)90149-5.
NAVROTCHI C, BADEA M E. The influence of occlusal stabilization appliances on cervical dystonia symptoms[J]. Clujul Med, 2017, 90(4): 438-444. DOI: 10.15386/cjmed-824.
皮昕.口腔解剖生理学[M].北京:人民卫生出版社, 2007: 1-316.
PI X. Oral anatomy and physiology[M]. Beijing: People's Medical Publishing House, 2007: 1-316.
BENAZZI S, KULLMER O, GROSSE I R, et al. Using occlusal wear information and finite element analysis to investigate stress distributions in human molars[J]. J Anat, 2011, 219(3): 259-272. DOI: 10.1111/j.1469-7580.2011.01396.x.
GAO G N, WANG G Y, SONG J W, et al. Three dimensional finite element analysis of the influence of stress on occlusal surface of the mandibular first molar[J]. Shanghai J Stomatol, 2016, 25(2): 162-167.
ZHANG H, CUI J W, LU X L, et al. Finite element analysis on tooth and periodontal stress under simulated occlusal loads[J]. J Oral Rehabil, 2017, 44(7): 526-536. DOI: 10.1111/joor.12512.
SHEIHAM A, JAMES W P. Diet and dental caries: the pivotal role of free sugars reemphasized[J]. J Dent Res, 2015, 94(10): 1341-1347. DOI: 10.1177/0022034515590377.
COSTALONGA M, HERZBERG M C. The oral microbiome and the immunobiology of periodontal disease and caries[J]. Immunol Lett, 2014, 162(2PtA): 22-38. DOI: 10.1016/j.imlet.2014.08.017.
KRZY S ' CIAK W, KO S ' CIELNIAK D, PAPIE Z · M, et al. Effect of a lactobacillus salivarius probiotic on a double-species Streptococcus mutans and candida albicans caries biofilm[J]. Nutrients, 2017, 9(11): 1242.
NISHIGAWA K, SUZUKI Y, ISHIKAWA T, et al. Effect of occlusal contact stability on the jaw closing point during tapping movements[J]. J Prosthodont Res, 2012, 56(2): 130-135. DOI: 10.1016/j.jpor.2011.04.005.
IMAMURA Y, SATO Y, KITAGAWA N, et al. Influence of occlusal loading force on occlusal contacts in natural dentition[J]. J Prosthodont Res, 2015, 59(2): 113-120. DOI: 10.1016/j.jpor.2014.07.001.
WANG M, MEHTA N. A possible biomechanical role of occlusal cusp-fossa contact relationships[J]. J Oral Rehabil, 2013, 40(1): 69-79. DOI: 10.1111/j.1365-2842.2012.02333.x.
DEJAK B, MLOTKOWSKI A, ROMANOWICZ M. Finite element analysis of mechanism of cervical lesion formation in simulated molars during mastication and parafunction[J]. J Prosthet Dent, 2005, 94(6): 520-529. DOI: 10.1016/j.prosdent.2005.10.001.
ZENG Y, WANG J D. Establishment of the three-dimensional finite element model of the first permanent mandibular molar and its stress analysis[J]. Chin J Stomatol, 2005, 40(5): 394-397.
徐樱华.徐樱华实用牙合学[M].北京:科学技术出版社, 2011: 1-2.
XU Y H. Practical Gnathology[M]. Beijing: Science and Technology Press, 2011: 1-2.
陈新民, 赵云凤.口腔生物力学[M].北京:科学出版社, 2010.
CHEN X M, ZHAO Y F. Oral biomechanics[M]. Beijing: Science Press, 2010.
MASUMOTO N, YAMAGUCHI K, FUJIMOTO S. Daily chewing gum exercise for stabilizing the vertical occlusion[J]. J Oral Rehabil, 2009, 36(12): 857-863. DOI: 10.1111/j.1365-2842.2009.02010.x.
CHAI H. On crack growth in molar teeth from contact on the inclined occlusal surface[J]. J Mech Behav Biomed Mater, 2015, 44: 76-84. DOI: 10.1016/j.jmbbm.2014.12.014.
FU G, DENG F, WANG L, et al. The three-dimension finite element analysis of stress in posterior tooth residual root restored with postcore crown[J]. Dent Traumatol, 2010, 26 (1): 64-69. DOI: 10.1111/j.1600-9657.2009.00829.x.
ZHOU H. 3-dimensional finite element analysis of superstructure of an implant under functional occlusions[D]. Tianjin: Tianjin Medical University, 2003.
CHEN Y, LIN Z M, LING J Q. Clinical observation on the characteristics of occlusion and tooth abrasion in patients with cracked tooth[J]. Chin J Stomatol, 2009, 44(9): 520-523.