Pengcheng TANG, Yin ZHU, Minzhu ZHAO, et al. Establishment of 3-D finite element model of elbow joint and its application for analysis of impact injury[J]. Journal of Third Military Medical University, 2018, 40(7): 596-602.
DOI:
Pengcheng TANG, Yin ZHU, Minzhu ZHAO, et al. Establishment of 3-D finite element model of elbow joint and its application for analysis of impact injury[J]. Journal of Third Military Medical University, 2018, 40(7): 596-602. DOI: 10.16016/j.1000-5404.201711237.
Establishment of 3-D finite element model of elbow joint and its application for analysis of impact injury
To establish a 3-D finite element model (FEM) of elbow joint
and analyze the biomechanical changes of the elbow joint in impact injury by dynamical simulation of elbow joint to impact the ground at different angels.
Methods
2
The finite element model of the elbow joint was established based on CT images of a young health male with his elbow joint bent at 90°
with aid of Mimics
Geomagic
UG and other softwares. Abaqus and Hypermesh softwares were used to simulate the injuries of the elbow joint impacting the ground at different angles (the angle of the forearm and the ground were 30°
60° and 90°
respectively). The critical velocities of cortical bone fracture and obvious fracture were calculated
and the patterns of conduction
intensity and distribution of the stress force were analyzed during impact process.
Results
2
When the elbow joint bent at 90° impacted the ground frontally
the conduction of the impact stress mainly concentrated in the humerus condyle
humerus trochlear and olecranon
but little in the radius. The critical velocities of cortical rupture were 11.4
9.3
and 13.8 m/s respectively
when the angulations were 30°
60°
and 90°. When the angulations were 30° and 60°
the impact velocities speeded up to 15.0 and 13.0 m/s
the olecranon had obvious fracture. Obvious transverse fracture was found in the distal humerus at the condition of angulations of 90° and velocity of 18.0 m/s.
Conclusion
2
The established FEM of elbow joint can be used in the biomechanical studies on mechanism of elbow injuries. It also provides new means to infer the intensity
velocity and direction of violence when the elbow joint is injured.
关键词
Keywords
references
MARTIN S, SANCHEZ E. Anatomy and biomechanics of the elbow ioint[J]. Semin Musculoskelet Radiol, 2013, 17(5):429-436. DOI:10.1055/s-0033-1361587.
ZHANG P N, JIA Y L, ZHANG X, et al . Biodynamics research of effect of disruption of elbow joint medial collateral ligament on humeroradial joint[J ] . ChinJ Bone Joint Injury, 2017, 32(5): 490-493. DOI:10.7531/j.issn.1672-9935.2017.05.012.
ZHANG J W, GAO S J, YANG X M, et al . The biomechanics research of anterior bundle in MCL injury of elbow joint[J ] . Orthopedic J Chin, 2012, 20(16): 1480-1483. DOI:10.3977/j.issn.1005-8478.2012.16.12.
WILLING R T, LALONE E A, SHANNON H, et al . Validation of a finite element model of the human elbow for determining cartilage contact mechanics[J ] . J Biomech, 2013, 46 (10): 1767-1771. DOI:10.1016/j.jbiomech.2013.04.001.
SUN J, YAN S, JIANG Y, et al . Finite element analysis of the valgus knee joint of an obese child[J ] . Biomed Eng Online, 2016, 15 (2): 309-321.
TANG B C, REN X J, ZOU X H.Finite element analysis of biomechanical comparison of cervical hybrid surgery in continuous two-level segments[J].J Third Mil Med Univ, 2015, 37(8):809-815. DOI:10.16016/j.1000-5404.201411247.
LI J, WANG H G, SHANG J, et al .Finite element analysis of stress distribution before and after segment fusion in transforaminal lumbar interbody fusion model[J ] .J Third Mil Med Univ, 2015, 37(14):1449-1454. DOI:10.16016/j.1000-5404. 201410189.
DUPREY S, BRUYERE K, VERRIEST J P. Human shoulder response to side impacts: a finite element study[J]. Comput Methods Biomech Biomed Engin, 2007, 10(5): 361-370. DOI:10.1080/10255840701463986.
王以进, 王介麟.骨科生物力学[M].北京:人民军医出版社, 1989:310.
WANG Y J, WANG J L. Orthopaedic Biomechanics[M].Beijing: People's Military Medical Press, 1989:310.
LAN C C, KUO C S, CHEN C H, et al . Finite element analysis of biomechanical behavior of whole thoraco-lumbar spine with ligamentous effect[J ] . Changhua J Med, 2013, 11 (1): 26-41.
CHENG L, HANNAFORD B. Finite element analysis for evaluating liver tissue damage due to mechanical compression[J]. J Biomech, 2015, 48 (6): 948-955. DOI:10.1016/j.jbiomech.2015.02.014.
ZENG Z. The establishment of the three-dimensional finite element model of the elbow and forearm in adult and the analysis of the stress conduction of the radial head[D]. Heng yang: University of South China, 2014.
ZHANG J X, TIAN H B, CHEN R Q. Three-dimensional limited element analysis of the complication after resection of head of radius for adults[J]. J Med Biomech, 2009, 24(6): 444-447.
TAN J. The study of the biomechanics of the lateral collateral ligament of the elbow joint by three-dimensional CT reconstruction[D]. Suzhou: Soochow University, 2014.
HAMEL A, LLARI M, PIERCECCHI-MARTI M D, et al . Effects of fall conditions and biologi cal variability on the mechanism of skull fractures caused by falls[J ] . Int J Legal Med, 2013, 127(1): 111-118. DOI:10.1007/s00414-011-0627-9.
YANG Z Y, QIU S B, LIU Y, et al . Biomechanical study on the impact injure of human mandible by finite element method[J ] . J Pract Stomatol, 2016, 32(3): 377-382. DOI:10.3969/j.issn.1001-3733.2016.03.017.
YANG Y P, XU D C, XU B K, et al . Analysis of the morphological structure and function of the collateral ligament of the elbow joint[J ] . Chin J Orthop, 2000, 20(6):345-347.
WANG Y H, LIU F, WANG H, et al . Study of radial collateral ligaments of elbow joint[J ] . J Nantong Univ (Med Sci), 2005, 25(1): 34-36. DOI:10.3969/j.issn.1674-7887.2005.01.011.
JI B, WANG Y H, ZHAO D Y, et al . Study on anatomy, function and biomechanis of medical collateral accessary ligamtnes of elbow[J ] .J Nantong Univ (Med Sci), 2006, 26(2): 97-99. DOI:10.3969/j.issn.1674-7887.2006.02.007.
MORREY B F, AN K N, STORMONT T J. Force transmission through the radial head[J]. J Bone Joint Surg Am, 1988, 70(2):250-256. DOI:10.2106/00004623-19887 0020-00014.
Finite element analysis of stress distribution before and after segment fusion in transforaminal lumbar interbody fusion model
Finite element analysis in scaphoid bone under action of axial stress
Finite element analysis on different types of rigid internal fixation for preventing postoperative fractures in cystic lesions of the mandibular angle
Finite element simulation and biomechanical analysis of indirect injury of temporomandibular joint under lateral impact on the angle of human mandible
Finite element analysis of mandibular first molar under different conditions of occlusal contact
Related Author
李杰
王洪岗
尚进
周跃
钦斌
黄永火
欧阳羽
吕发金
Related Institution
Key Laboratory of Oral Biomedical Engineering of Higher Education, Chongqing Key Laboratory for Oral Diseases and Biomedical Sciences, Stomatological Hospital of Chongqing Medical University