Jian FU, Wenhao SHEN. Curative efficacy and safety of 2 surgical approaches in management of female stress urinary incontinence: a prospective randomized controlled trial[J]. Journal of Third Military Medical University, 2017, 39(24): 2418-2422.
DOI:
Jian FU, Wenhao SHEN. Curative efficacy and safety of 2 surgical approaches in management of female stress urinary incontinence: a prospective randomized controlled trial[J]. Journal of Third Military Medical University, 2017, 39(24): 2418-2422. DOI: 10.16016/j.1000-5404.201709004.
Curative efficacy and safety of 2 surgical approaches in management of female stress urinary incontinence: a prospective randomized controlled trial
To compare the effectiveness and complications of adjustable single-incision sling (TVT-Ajust) and modified tension-free vaginal tape-obturator (TVT-Abbrevo)for the treatment of female stress urinary incontinence(SUI).
Methods
2
A total of 60 female patients with SUI admitted in our institute from March 2015 to July 2016 were enrolled in this study
and then randomly assigned into TVT-Abbrevo and TVT-Ajust groups (
n
=30 for each group).The patients were at an average age of 50.5±7.6 years and had a mean body mass index(BMI) of 24.9±3.3. Their age
BMI
parity
maximum flow rate
and abdominal leak point pressure (ALPP) were evaluated before operation. Operation time
intraoperative bleeding volume
operation-related complications
postoperative pain
objective and subjective cure rates
and quality of life were compared between the 2 groups.
Results
2
The intraoperative bleeding volume was significantly less in the TVT-Ajust group than the TVT-Abbrevo (
P
<
0.05). There were 4 cases of postoperative dysuria
with each group having 2 cases
and vaginal sling corrosion was found in 1 case from the TVT-Ajust group. The patients of TVT-Ajust
group experienced obviously milder postoperative pain than those of the TVT-Abbrevo group at 4 weeks after surgery(
P
<
0.05). There were no notable differences in objective and subjective cure rates between the 2 groups(
P
>
0.05). The quality of life was obviously improved in all the 60 patients after surgery (
P
<
0.05). However
both surgical approaches could not significantly improve the symptoms of urge incontinence.
Conclusion
2
TVT-Ajust procedure is safe and effective in treatment of female SUI. Compared with TVT-Abbrevo
it has less amount of intraoperative bleeding
milder postoperative pain
reduced incidence of postoperative moderate to severe pain
and faster postoperative recovery. But long-term outcomes need to be further observed.
关键词
Keywords
references
AGUR W, RIAD M, SECCO S, et al.Surgical treatment of recurrentstressurinaryincontinence in women: asystematicreview and meta-analysis of randomisedcontrolledtrials[J]. Eur Urol, 2013, 64(2): 323-336. DOI: 10.1016/j.eururo.2013.04.034.
LEONE ROBERTI MAGGIORE U, FINAZZI AGRO E, SOLIGO M, et al. Long-term outcomes of TOT and TVT procedures for the treatment of female stress urinary incontinence: a systematic review and meta-analysis[J]. Int Urogynecol J, 2017, 28(8): 1119-1130. DOI: 10.1007/s00192-017-3275-x.
DELEVAL J. Novel surgical technique for the treatment of female stress urinaryincontinence: transobturatorvaginaltape inside-out[J]. Eur Urol, 2003, 44: 724-730. DOI: 10.1016/j.eururo.2004.03.013.
CANEL V, THUBERT T, WIGNIOLLE I, et al. Postoperative groin pain and success rates following transobturator midurethral sling placement: TVT ABBREVO ® system versus TVT TM obturator system[J ] . Int Urogynecol J, 2015, 26(10): 1509-1516. DOI: 10.1007/s00192-015-2723-8..
LI W L, LU Z W, LI F P, et al.A comparative study on treating femal stress urinary incontinence with TVT-Abbrevo and TVT-Obturator[J]. Natl Med J China, 2016, 96(28): 2238-2240. DOI: 10.3760/cma.j.issn.0376-2491.2016.28.008.
LI F P, WANG L Z, LI W L, et al. TVT-Abbrevo in treatment of female stress urinary incontinence[J].J Clin Urology(China), 2014, 29(12): 1064-1066. DOI: 10.13201/j.issn.1001-1420.2014.12.007.
PALOMBA S, OPPEDISANO R, TORELLA M, et al. A randomized controlled trial comparing three vaginal kitsof single-incision mini-slings for stress urinary incontinence: surgical data[J]. Eur J Obstet Gynecol Reprod Biol, 2012, 163(1): 108-112. DOI: 10.1016/j.ejogrb.2012.03.038.
CARMEL M E, DENG D Y, GREENWELL T J, et al. Definition of Success after Surgery for Female Stress Incontinence or Voiding Dysfunction:AnAttempt at Standardization[J]. Eur Urol Focus, 2016, 2(3): 231-237. DOI: 10.1016/j.euf.2016.03.005.
BLAIVAS J G, PANAGOPOULOS G, WEISS J P, et al. The urgency perception score: validation and test-retest[J]. J Urol, 2007, 177(1): 199-202. DOI: 10.1016/j.juro.2006.08.091.
ROGERS R G, COATES K W, KAMMERER-DOAK D, et al. A short form of the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire (PISQ-12)[J]. Int Urogynecol J Pelvic Floor Dysfunct, 2003, 14(3): 164-168. DOI: 10.1007/s00192-003-1063-2.
ULRICH D, BJELIC-RADISIC V, GRABNER K, et al. Objective outcome and quality-of-life assessment in women with repeat incontinence surgery[J]. Neurourol Urodyn, 2017, 36(6): 1543-1549. DOI: 10.1002/nau.23144.
MOSTAFA A, AGUR W, ABDEL-ALL M, et al. A multicentre prospective randomised study of single-incision mini-sling (Ajust ® ) versus tension-free vaginal tape-obturator (TVT-O TM ) in the management of female stress urinary incontinence: pain profile and short-term outcomes[J ] . Eur J Obstet Gynecol Reprod Biol, 2012, 165(1): 115-121. DOI: 10.1016/j.ejogrb.2012.06.022..
MASATA J, SVABIK K, ZVARA K, et al. Comparison of the efficacy of tension-free vaginal tape obturator (TVT-O) and single-incision tension-free vaginal tape (Ajust ® ) in the treatment of female stress urinary incontinence:a 1-year follow-up randomized trial[J ] . Int Urogynecol J, 2016, 27(10): 1497-1505. DOI: 10.1007/s00192-016-3012-x.
XIN X, SONG Y, XIA Z. A comparison between adjustable single-incision sling and tension-free vaginal tape-obturator in treating stress urinary incontinence[J]. Arch Gynecol Obstet, 2016, 293(2): 457-463. DOI: 10.1007/s00404-015-3949-x.
MOSTAFA A, AGUR W, ABDEL-ALL M, et al. Multicenter prospective randomized study of single-incision mini-sling vs tension-free vaginal tape-obturator in management of female stress urinary incontinence:a minimum of 1-year follow-up[J]. Urology, 2013, 82(3): 552-559. DOI: 10.1016/j.urology.2013.02.080.
Cold versus hot snare polypectomy in treatment of small colorectal polyps: a retrospective study on safety and efficacy
Transcatheter aortic valve replacement: clinical researches and progress of application
Risk factors and treatment strategies of digestive tract foreign body perforation
Clinical characteristics and endoscopic treatment of suprasellar Rathke cleft cysts
Predictive values of proportional postoperative reduction of albumin for postoperative complications and long-term outcomes following sphincter-preserving surgery for rectal cancer
Related Author
Jinlong HE
Lei CHEN
Jing CHEN
Xiaofeng FENG
Yao CHEN
Lixia DUAN
Dianchun FANG
Qing JI
Related Institution
Department of Gastroenterology, First Affiliated Hospital, Army Medical University (Third Military Medical University)
Department of Cardiology, Institute of Cardiology, Second Affiliated Hospital, Army Medical University (Third Military Medical University)
Department of Vascular Surgery, the First Affiliated Hospital of Chongqing Medical University
Department of Gastrointestinal and Neonatal Surgery, Key Laboratory of Child Development and Disorders Co-founded by Chongqing and Ministry of Education, Chongqing International Science and Technology Cooperation Center for Child Development and Disoeders, Chongqing Key Laboratory of Pediatrics, Children's hospital of Chongqing Medical University