Comparison of echocardiographic findings of fetal pulmonary stenosis before and after delivery
Clinical Medicine|更新时间:2026-01-09
|
Comparison of echocardiographic findings of fetal pulmonary stenosis before and after delivery
Journal of Third Military Medical UniversityVol. 39, Issue 12, Pages: 1268-1274(2017)
作者机构:
400038 重庆,第三军医大学西南医院超声科
作者简介:
基金信息:
"Twelfth Five-year Plan" for National Key Technology R & D Program(2014BA106B00);Science and Technology Wellbeing Project of Chongqing(CSTC2015jcsf40001)
Jianjun Liu, Yanli Guo, Lingmin Duan, et al. Comparison of echocardiographic findings of fetal pulmonary stenosis before and after delivery[J]. Journal of Third Military Medical University, 2017, 39(12): 1268-1274.
DOI:
Jianjun Liu, Yanli Guo, Lingmin Duan, et al. Comparison of echocardiographic findings of fetal pulmonary stenosis before and after delivery[J]. Journal of Third Military Medical University, 2017, 39(12): 1268-1274. DOI: 10.16016/j.1000-5404.201701002.
Comparison of echocardiographic findings of fetal pulmonary stenosis before and after delivery
To compare the echocardiographic characteristics of fetal pulmonary stenosis before and after delivery.
Methods
2
Sixteen fetuses with a confirmed or suspected diagnosis of pulmonary stenosis by echocardiography in our department from June 2014 to June 2016 were analyzed. The sonographic features of pulmonary stenosis in echocardiography and the hemodynamic parameters before and after delivery were compared. The misdiagnosis and missed diagnosis were analyzed in these cases.
Results
2
Within 1 month after birth
echocardiography confirmed pulmonary stenosis in 13 newborns
including 10 with uncomplicated pulmonary valve stenosis. The cases with severe pulmonary stenosis showed characteristic echocardiographic features
including severe tricuspid regurgitation
a large right atrium
a small right ventricle
and retrograde blood flow in the arterial duct
which were all associated with a poor prognosis. In cases with mild or moderate pulmonary stenosis
prenatal echocardiography showed no characteristic findings to easily cause missed diagnosis
and follow-up echocardiography may show gradual alleviation of the stenosis
but in 2 cases
the condition could deteriorate progressively. Three cases were confirmed to have pulmonary stenosis with concurrent intracardiac malformation and consistent pre-and postnatal echocardiographic findings
and all these 3 cases had a poor prognosis. In another 3 cases
echocardiography after delivery showed normal pulmonary artery although they were diagnosed to have mild pulmonary stenosis by prenatal echocardiography.
Conclusion
2
The hemodynamics of fetal pulmonary artery stenosis can present with characteristic changes in echocardiography after birth
suggesting the need of close and regular echocardiographic follow-up of the fetuses to assess the changes of stenosis and the prognosis.
Dong F Q, Zhao Z. Practical clinical ultrasonic diagnosis of congenital heart diseases[M]. 2nd ed. Beijing: People's Military Medical Press, 2011: 67-72.
Jie L L, Xu Y, Cheng J, et al. Characteristics and diagnostic value of ultrasonogram for fetal simple pulmonary artery stenosis [J]. Chin J Ultrasonogr, 2012, 21(12): 1082-1083. DOI: 10.3760/ cma.j.issn 1004-4477.2012.12.024.
Jia L, Li J, Zhou X D, et al. Two-dimensional and doppler echocardiography in the diagnosis of congenital simple pulmonary stenosis[J]. Chin Heart J, 2001, 13(2): 158-159. DOI:10.3969/j.issn.1009-7236.2001.02.034.
Liu Y L, Xiao Y, Hu X F. The ultrasonic characteristics of fetal pulmonary stenosis[J]. J Clin Res, 2014, 31(2): 383-384. DOI: 10.3969/j.issn.1671-7171.2014.02.064.
Shou L J, Xie Z P, Shen X Y, et al. Comparison of prenatal and postpartum ultrasonic diagnosis for pulmonary artery stenosis and strategies for missed diagnosis[J]. Chin J Birth Health Heredity, 2015, 23(8): 98-99. DOI: 10.13404/j.cnki.cjbhh.2015.08.044.
Peterson R E, Levi D S, Williams R J, et al. Echocardiographic predictors of outcome in fetuses with pulmonary atresia with intact ventricular septum[J]. J Am Soc Echocardiogr, 2006, 19(11): 1393-1400. DOI: 10.1016/j.echo.2006.05.021.
Favilli S, Giusti S, Vangi V, et al. Pulmonary atresia or critical pulmonary stenosis with intact interventricular septum diagnosed in utero: echocardiographic findings and post-natal outcome[J]. Pediatr Med Chir, 2003, 25(4): 266-268.
Zhang Y, He Y H, Sun L, et al. Analysis of the relationship between reverse ductus arteriosus flow and pulmonary development of fetal with right ventricular obstructive lesions [J]. Chin J Ultrasound Med, 2015, 31(4): 355-357.
Jie L L, Liu Q H, Xu Y, et al. Diagnostic value of ultrasonogram for fetal simple pulmonary artery stenosis [J]. Chin J Ultrasonogr, 2006, 15(1): 68-69. DOI: 10.3760/j.issn:1004-4477.2006.01.019.
李治安.临床超声影像学[M].北京:人民卫生出版社, 2003: 640-643.
Li Z A. Clinical ultrasound imaging[M]. Beijing: People's Medical Publising House, 2003: 640-643.
Xie L Y, Xie Z P, Jin S H, et al. Fetal prenatal ultrasound diagnosis value of right ventricular dysplasia[J]. Chin J Birth Health Hered, 2016, 24(1): 87-87. DOI: 10.13404/j.cnki.cjbhh.2016.01.034.
Vi als F, Heredia F, Giuliano A. The role of the three vessels and trachea view (3VT) in the diagnosis of congenital heart defects[J]. Ultrasound Obstet Gynecol, 2003, 22(4): 358-367. DOI: 10.1002/uog.882.
Qian X H, Jin J W. Clinical analysis of abnormal pulmonary artery in fetus detected by obstetric ultrasound from three vessel trachea views [J]. Chin J Woman Child Health Res, 2016, 27(5): 637-639. DOI: 10.3969/j.issn.1673-5293.2016.05.030.
Wei Y F, Zhang H F, Ding Q.Diagnostic value of echocardiography for fetal simple pulmonary artery stenosis[J]. J Clin Ultrasound in Med, 2015, 17(8): 571-572. DOI: 10.16245/j.cnki.issn 1008-6978.2015.08.033.
Zhao Y L, Cai A L, Zhang Y, et al. Ductus venous flow waveforms in fetuses with pulmonary stenosis[J]. Chin J Med Imaging Technol, 2010, 26(7): 1314-1317.
Lu H Y, Zhao B W, Pan M, et al. Quantification of z-scores of fetal aortic and pulmonary artery diameters using echocardiography[J]. Chin J Ultrasonography, 2013, 22(2): 111-114. DOI: 10.3760/ema.j.issn.1004-4477.2013.02.006.
Comparison on myocardial injury in rats with classic versus exertional heat stroke
Efficacy of surgical valve surgery for end stage atrial fibrillation: a report of 693 cases
Assessment of coronary artery anatomy in patients with transposition of the great arteries using dual-source computed tomography
Normal reference values for left ventricular peak systolic longitudinal strain and strain rate in healthy children at different ages: a preliminary analysis
Multifunctional echocardiography for right ventricular function in fetuses suffering from double outlet right ventricle or Tetralogy of Fallot
Related Author
杨学森
刘晓倩
申婷婷
李萍
何根林
谭雨龙
王泽泽
罗珍
Related Institution
Department of Radiology, West China Hospital, Sichuan University
Department of Radiology, Sichuan Cancer Hospital & Institute
Department of Ultrasonography, Children's Hospital of Chongqing Medical University
Department of Epidemiology and Bioinformatics, Children's Hospital of Chongqing Medical University
Pediatric Research Institute, Children's Hospital of Chongqing Medical University