Jing Wen, Jianzhong Zou, Qi Wang, et al. Efficacy of surface ablation with continuous versus pulsed high-intensity focused ultrasound in isolated bovine liver[J]. Journal of Third Military Medical University, 2017, 39(8): 749-754.
Jing Wen, Jianzhong Zou, Qi Wang, et al. Efficacy of surface ablation with continuous versus pulsed high-intensity focused ultrasound in isolated bovine liver[J]. Journal of Third Military Medical University, 2017, 39(8): 749-754. DOI: 10.16016/j.1000-5404.201610064.
Objective
2
To compare the effect of surface ablation with continuous high-intensity focused ultrasound (CHIFU) and pulsed high-intensity focused ultrasound (PHIFU) and investigate the optimization of surface ablation mode with HIFU.
Methods
2
Forty samples of fresh bovine liver tissues were divided into group A (
n
=30) and group B (
n
=10) for surface ablation with PHIFU and CHIFU
respectively. According to the duty cycles
the samples in group A were divided into 3 equal subgroups with duty cycles of 10% (group A1)
30% (group A2)
and 50% (group A3). With ultrasonographic guidance
the target areas in the liver tissues were irradiated with PHIFU and CHIFU for surface ablation
and the temperature changes in the geometric center of the target area were recorded. After ablation
tissue damages in the peripheral area and the areas within and outside the target area were observed
the energy efficiency factor (EEF) was calculated
and the temperature-time curve was analyzed.
Results
2
Compared with that in group B
the EEF in the 3 subgroups in group A all reduced significantly (
P
<
0.05)
and the reduction became more prominent as the duty cycles increased. Thermal damage outside the target area was observed only in group B. In each group
confined lesions were formed following the ablation
and the irradiated areas showed liquid necrosis in subgroup A1 and coagulation necrosis in the other groups. Within the target area of ablation
the tissue damage was intensified as the duty cycle increased
and the peak temperature in the center of the target area exceeded 60 ℃ in all the groups only with the exception of group A1.
Conclusion
2
Compared with CHIFU surface ablation
PHIFU surface ablation has a greater ablation efficiency and reduces tissue damage outside the target area. In PHIFU peripheral ablation
the temperature and tissue damage of the non-irradiated internal tissue within the target area can be controlled by adjusting the duty cycles.
Wu F High intensity focused ultrasound: A noninvasive therapy for locally advanced pancreatic cancer World J Gastroenterol 2014 20 44 16480 16488 10.3748/wjg.v20.i44.16480 Wu F. High intensity focused ultrasound: A noninvasive therapy for locally advanced pancreatic cancer[J]. World J Gastroenterol, 2014, 20(44):16480-16488. DOI:10.3748/wjg.v20.i44.16480.
Horsman M R Vaupel P Pathophysiological basis for the formation of the tumor microenvironment Front Oncol 2016 6 66 10.3389/fonc.2016.00066 Horsman M R, Vaupel P. Pathophysiological basis for the formation of the tumor microenvironment[J]. Front Oncol, 2016, 6: 66. DOI:10.3389/fonc.2016.00066.
Bu R Yin L Yang H Tissue ablation accelerated by peripheral scanning mode with high-intensity focused ultrasound: a study on isolated porcine liver perfusion Ultrasound Med Biol 2013 39 8 1410 1419 10.1016/j.ultrasmedbio.2013.03.012 Bu R, Yin L, Yang H, et al . Tissue ablation accelerated by peripheral scanning mode with high-intensity focused ultrasound: a study on isolated porcine liver perfusion[J ] . Ultrasound Med Biol, 2013, 39(8):1410-1419. DOI:10. 1016/j.ultrasmedbio. 2013.03.012.
银 丽 邹 建中 伍 烽 HIFU三维周边式辐照阻断离体灌注猪肝局部血供的可行性 中国介入影像与治疗学 2013 10 2 65 68 10.13929/j.1672-8475.2013.02.016. 银丽, 邹建中, 伍烽, 等. HIFU三维周边式辐照阻断离体灌注猪肝局部血供的可行性[J].中国介入影像与治疗学, 2013, 10(2): 65-68. DOI:10.13929/j.1672-8475.2013.02.016.
Yin L Zou J Z Wu F Feasibility of HIFU 3D-peripheral scanning on blocking the local blood supply of isolated perfused pig liver tissue Chin J Interv Imaging Ther 2013 10 2 65 68 10.13929/j.1672-8475.2013.02.016 Yin L, Zou J Z, Wu F, et al . Feasibility of HIFU 3D-peripheral scanning on blocking the local blood supply of isolated perfused pig liver tissue[J ] . Chin J Interv Imaging Ther, 2013, 10(2): 65-68. DOI:10.13929/j.1672-8475.2013.02.016.
许 利劼 邹 建中 高强度聚焦超声治疗"困难部位"肝癌的安全性及有效性 临床超声治疗学杂志 2014 16 3 182 184 10.16245/j.cnki.issn1008-6978.2014.03.041. 许利劼, 邹建中.高强度聚焦超声治疗"困难部位"肝癌的安全性及有效性[J].临床超声治疗学杂志, 2014, 16(3): 182-184. DOI:10.16245/j.cnki.issn1008-6978.2014. 03.041.
Xu L J Zou J Z Safety and efficacy of high intensity focused ultrasound therapy for liver cancer in"difficult locations" J Clin Ultrasound in Med 2014 16 3 182 184 10.16245/j.cnki.issn1008-6978.2014.03.041 Xu L J, Zou J Z.Safety and efficacy of high intensity focused ultrasound therapy for liver cancer in"difficult locations"[J]. J Clin Ultrasound in Med, 2014, 16(3):182-184. DOI:10. 16245/j.cnki.issn1008-6978.2014.03.041.
李 成海 王 静 李 非 聚焦超声辐照仿组织体模过程中实时气泡活动及其对损伤的影响 中国介入影像与治疗学 2015 12 7 437 440 10.13929/j.1672-8475.2015.07.014. 李成海, 王静, 李非, 等.聚焦超声辐照仿组织体模过程中实时气泡活动及其对损伤的影响[J].中国介入影像与治疗学, 2015, 12(7): 437-440. DOI:10.13929/j.1672-8475.2015.07.014.
Li C H Wang J Li F Real-time bubble activities and its effects in process of irradiation by focused ultrasound in tissue-mimicking phantom Chin J Interv Imaging Ther 2015 12 7 437 440 10.13929/j.1672-8475.2015.07.014 Li C H, Wang J, Li F, et al .Real-time bubble activities and its effects in process of irradiation by focused ultrasound in tissue-mimicking phantom[J ] . Chin J Interv Imaging Ther, 2015, 12(7): 437-440. DOI:10.13929/j.1672-8475.2015.07.014.
何 炜 王 维 周 平 HIFU非热效应诱导兔肝VX2肿瘤损伤 中国医学影像技术 2010 26 12 2235 2238 http://www.cnki.com.cn/Article/CJFDTOTAL-ZYXX201012005.htm 何炜, 王维, 周平, 等. HIFU非热效应诱导兔肝VX2肿瘤损伤[J].中国医学影像技术, 2010, 26(12): 2235-2238.
He W Wang W Zhou P Injury on rabbit hepatic VX2 tumor induced by non-thermal effects of high-intenstiy focused ultrasound Chin J Med Imaging Techol 2010 26 12 2235 2238 http://www.cnki.com.cn/Article/CJFDTOTAL-ZYXX201012005.htm He W, Wang W, Zhou P, et al . Injury on rabbit hepatic VX2 tumor induced by non-thermal effects of high-intenstiy focused ultrasound[J ] . Chin J Med Imaging Techol, 2010, 26(12): 2235-2238.
杨 含 白 晋 刁 庆春 连续高强度聚焦超声与脉冲高强度聚焦超声的生物学效应对比 中国介入影像与治疗学 2013 10 2 69 72 http://www.cnki.com.cn/Article/CJFDTOTAL-JRYX201302002.htm 杨含, 白晋, 刁庆春, 等.连续高强度聚焦超声与脉冲高强度聚焦超声的生物学效应对比[J].中国介入影像与治疗学, 2013, 10(2): 69-72.
Yang H Bai J Diao Q C Comparison on biological effects of continuous and pulse high intensity focused ultra sound Chin J Interv Imaging Ther 2013 10 2 69 72 http://www.cnki.com.cn/Article/CJFDTOTAL-JRYX201302002.htm Yang H, Bai J, Diao Q C, et al . Comparison on biological effects of continuous and pulse high intensity focused ultra sound[J ] . Chin J Interv Imaging Ther, 2013, 10(2): 69-72.
Ma C M Chen X Cvetkovic D An in-vivo investigation of the therapeutic effect of pulsed focused ultrasound on tumor growth Med Phys 2014 41 12 122901 10.1118/1.4901352 Ma C M, Chen X, Cvetkovic D, et al . An in-vivo investigation of the therapeutic effect of pulsed focused ultrasound on tumor growth[J ] . Med Phys, 2014, 41(12): 122901. DOI:10.1118/1.4901352.
Lee S H Jeong D Han Y S Pivotal role of vascular endothelial growth factor pathway in tumor angiogenesis Ann Surg Treat Res 2015 89 1 1 8 10.4174/astr.2015.89.1.1 Lee S H, Jeong D, Han Y S, et al . Pivotal role of vascular endothelial growth factor pathway in tumor angiogenesis[J ] . Ann Surg Treat Res, 2015, 89(1):1-8. DOI:10.4174/astr.2015.89.1.1.
Dvorak H F Tumor Stroma, Tumor Blood Vessels, and Antiangiogenesis Therapy Cancer J 2015 21 4 237 243 10.1097/PPO.0000000000000124 Dvorak H F. Tumor Stroma, Tumor Blood Vessels, and Antiangiogenesis Therapy[J]. Cancer J, 2015, 21(4): 237-243. DOI:10.1097/PPO.0000000000000124.
Jhaveri N Chen T C Hofman F M Tumor vasculature and glioma stem cells: Contributions to glioma progression Cancer Lett 2016 380 2 545 551 10.1016/j.canlet.2014.12.028 Jhaveri N, Chen T C, Hofman F M. Tumor vasculature and glioma stem cells: Contributions to glioma progression[J]. Cancer Lett, 2016, 380(2): 545-551.DOI:10.1016/j.canlet.2014.12.028.
Marx V Tracking metastasis and tricking cancer Nature 2013 494 7435 133 136 10.1038/494131a Marx V. Tracking metastasis and tricking cancer[J]. Nature, 2013, 494(7435):133-136.DOI:10.1038/494131a.
Peng S Zhou P He W Treatment of hepatic tumors by thermal versus mechanical effects of pulsed high intensity focused ultrasound in vivo Phys Med Biol 2016 61 18 6754 6769 10.1088/0031-9155/61/18/6754 Peng S, Zhou P, He W, et al . Treatment of hepatic tumors by thermal versus mechanical effects of pulsed high intensity focused ultrasound in vivo[J ] . Phys Med Biol, 2016, 61(18): 6754-6769. DOI:10.1088/0031-9155/61/18/6754.
Khokhlova V A Fowlkes J B Roberts W W Histotripsy methods in mechanical disintegration of tissue: towards clinical applications Int J Hyperthermia 2015 31 2 145 162 10.3109/02656736.2015.1007538 Khokhlova V A, Fowlkes J B, Roberts W W, et al . Histotripsy methods in mechanical disintegration of tissue: towards clinical applications[J ] . Int J Hyperthermia, 2015, 31(2):145-162.DOI:10.3109/02656736.2015.1007538.
Zhou Y Gao X W Effect of hydrodynamic cavitation in the tissue erosion by pulsed high-intensity focused ultrasound (pHIFU) Phys Med Biol 2016 61 18 6651 6667 10.1088/0031-9155/61/18/6651 Zhou Y, Gao X W. Effect of hydrodynamic cavitation in the tissue erosion by pulsed high-intensity focused ultrasound (pHIFU)[J]. Phys Med Biol, 2016, 61(18): 6651-6667. DOI:10.1088/0031-9155/61/18/6651.
0
Views
0
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621