Liu Wenjie,Xiao Zhibo,Yu Bin,et al.Impact of different flip angles on the image quality of female pelvic susceptibility-weighted imaging[J].Journal of Chongqing Medical University,2025,50(12):1737-1743.
Liu Wenjie,Xiao Zhibo,Yu Bin,et al.Impact of different flip angles on the image quality of female pelvic susceptibility-weighted imaging[J].Journal of Chongqing Medical University,2025,50(12):1737-1743. DOI: 10.13406/j.cnki.cyxb.003849.
Impact of different flip angles on the image quality of female pelvic susceptibility-weighted imaging
纳入44例行盆腔MRI增强的患者。测量各组病变、子宫及臀大肌的信号强度(signal intensity,SI)、标准差(standard deviation,SD),计算信噪比(signal to noise ratio,SNR)、对比噪声比(contrast to noise ratio,CNR);采用4分法对盆腔各部位的解剖细节显示、几何畸形程度、伪影和病灶清晰度进行主观评价;采用非参数Friedman检验进行SNR、CNR及主观评分多组间比较,采用LSD-
To investigate the impact of flip angle (FA) on the image quality of female pelvic susceptibility-weighted imaging(SWI).
Methods
2
A total of 44 patients undergoing contrast-enhanced pelvic MRI were enrolled in this study. The signal intensity and standard deviation of lesion,uterus,and gluteus maximus were measured for each group,and signal-to-noise ratio(SNR) and contrast-to-noise ratio(CNR) were calculated. The 4-point method was used to perform subjective evaluation of anatomical details,the degree of geometric deformation,artifacts,and the clarity of lesions in each part of the pelvic cavity. The non-parametric Friedman test was used for comparison of SNR,CNR,and subjective scores between groups,and the least significant difference
t
-test was used for post-hoc comparison of SNR,CNR,and subjective scores between groups,while Bonferroni correction was performed on the results. The intraclass correlation coefficient(ICC) was used to investigate the consistency in objective and subjective scores between two observers.
Results
2
There was good consistency in subjective scores the two observers in all groups(ICC
>
0.75) except for the degree of geometric deformation in the FA=15° and FA=20° groups(ICC=0.75). The SNR values of lesion,gluteus maximus,and uterus was 132.33±34.15,61.90±15.41,and 103.89±22.48,respectively,in the FA=10° group,with sig
nificant differences compared with the FA=15° and FA=20° groups(
P
<
0.001). The FA=10° group had the highest CNR value of lesion(69.67±29.15),with significant differences compared with the FA=15° and FA=20° groups(
P
<
0.001).
Conclusion
2
Reducing FA can significantly improve the contrast of female pelvic images,and the SWI image quality of female pelvic cavity can be improved at an FA of10°,which can be used as the optimal regimen for setting parameters for female pelvic SWI imaging in clinical practice.
关键词
Keywords
references
Song S , Zhang D , Wang Y , et al . Changing trends in the disease burden of uterine cancer globally from 1990 to 2019 and its predicted level in 25 years [J ] . Front Oncol , 2024 , 14 : 1361419 .
Ji X , Duan H , Wang Set al . Low-intensity pulsed ultrasound in obstetrics and gynecology:advances in clinical application and research progress [J ] . Front Endocrinol(Lausanne) , 2023 , 14 : 1233187 .
Fan L , Ma L , Ling R , et al . Clinical value of conventional magnetic resonance imaging combined with diffusion-weighted imaging in predicting pelvic lymph node metastasis of cervical cancer [J ] . Front Oncol , 2023 , 13 : 1267598 .
Bazot M , Bharwani N , Huchon C , et al . European Society of urogenital radiology(ESUR) guidelines:MR imaging of pelvic endometriosis [J ] . Eur Radiol , 2017 , 27 ( 7 ): 2765 - 2775 .
Guerra A , Daraï E , Osório F , et al . Imaging of postoperative endometriosis [J ] . Diagn Interv Imaging , 2019 , 100 ( 10 ): 607 - 618 .
Li B , Hu Y Z , Li X S . Progress of imaging studies on secondary brain injury after spontaneous cerebral hemorrhage [J ] . Chin J Stroke , 2023 , 18 ( 3 ): 347 - 352 .
Tay KL , Leason SR , Dawes LC , et al . Haemorrhage and calcification on susceptibility-weighted imaging:a quick and reliable qualitative technique for differentiating lesions with ambiguous phase [J ] . Clin Neuroradiol , 2022 , 32 ( 3 ): 705 - 715 .
Yan SM , Dong XY , Ding DW , et al . Iron deposition in ovarian endometriosis evaluated by magnetic resonance imaging R2* correlates with ovarian function [J ] . Reprod Biomed Online , 2023 , 47 ( 3 ): 103231 .
Mohammadi S , Ghaderi S . Parkinson’s disease and Parkinsonism syndromes:evaluating iron deposition in the putamen using magnetic susceptibility MRI techniques-A systematic review and literature analysis [J ] . Heliyon , 2024 , 10 ( 7 ): e27950 .
Martín-Noguerol T , Santos-Armentia E , Ramos A , et al . An update on susceptibility-weighted imaging in brain gliomas [J ] . Eur Radiol , 2024 , 34 ( 10 ): 6763 - 6775 .
Liu S , Buch S , Chen Y , et al . Susceptibility-weighted imaging:current status and future directions [J ] . NMR Biomed , 2017 , 30 ( 4 ): 10 .
Franco PN , Annibali S , Viganò S , et al . T2*-weighted imaging performance in the detection of deep endometriosis among readers with different experience:Comparison with conventional MRI sequences [J ] . Diagnostics(Basel) , 2022 , 12 ( 7 ): 1545 .
Haacke EM , Mittal S , Wu Z , et al . Susceptibility-weighted imaging:technical aspects and clinical applications,part 1 [J ] . AJNR Am J Neuroradiol , 2009 , 30 ( 1 ): 19 - 30 .
Mittal S , Wu Z , Neelavalli J , et al . Susceptibility-weighted imaging:technical aspects and clinical applications,part 2 [J ] . AJNR Am J Neuroradiol , 2009 , 30 ( 2 ): 232 - 252 .
Morbée L , Vereecke E , Laloo F , et al . MR Imaging of the pelvic bones:The current and cutting-edge techniques [J ] . J Belg Soc Radiol , 2022 , 106 ( 1 ): 123 .
Sakala MD , Shampain KL , Wasnik AP . Advances in MR imaging of the female pelvis [J ] . Magn Reson Imaging Clin N Am , 2020 , 28 ( 3 ): 415 - 431 .
Pin L , Monseau-Thiburce AC , Ziade-Coularis C , et al . Exploratory study of the interest of MR susceptibility-weighted imaging for the pre-operative assessment of pelvic endometriosis extent [J ] . Eur J Radiol , 2019 , 118 : 245 - 250 .
Guerriero S , Ajossa S , Pagliuca M , et al . Advances in imaging for assessing pelvic endometriosis [J ] . Diagnostics(Basel) , 2022 , 12 ( 12 ): 2960 .
Chen H , Wang G , Wang X , et al . Diagnostic value of susceptibility-weighted imaging for endometrioma:preliminary results from a retrospective analysis [J ] . Acta Radiol , 2022 , 63 ( 7 ): 976 - 981 .
Arribarat G , Cartiaux B , Boucher S , et al . Ex vivosusceptibility-weighted imaging anatomy of canine brain-comparison of imaging and histological sections [J ] . Front Neuroanat , 2022 , 16 : 948159 .
Halefoglu AM , Yousem DM . Susceptibility weighted imaging:Clinical applications and future directions [J ] . World J Radiol , 2018 , 10 ( 4 ): 30 - 45 .
Schmidt VF , Dietrich O , Kazmierczak PM , et al . Optimized visualization of focal liver lesions and vascular structures in real-time T1-weighted gradient echo sequences for magnetic resonance-guided liver procedures [J ] . Diagn Interv Radiol , 2023 , 29 ( 1 ): 128 - 137 .
Ren X , Zhao Y , Zhou L P , et al . Effects of different flip angles and delay times on image quality of liver and biliary system in hepatobiliary phase images of Gd-BOPTA-enhanced magnetic resonance images [J ] . Chin J Magn Reson Imaging , 2024 , 15 ( 2 ): 147 - 154 .
Jeon I , Cho ES , Kim JH , et al . Feasibility of 10-minute delayed hepatocyte phase imaging using a 30° flip angle in Gd-EOB-DTPA-enhanced liver MRI for the detection of hepatocellular carcinoma in patients with chronic hepatitis or cirrhosis [J ] . PLoS One , 2016 , 11 ( 12 ): e0167701 .
Cai L , Chen GY , Lyu Q , et al . Study on the effect of different flip angles on the image quality of Gd-EOB-DTPA-enhanced 3.0 T MRI in biliary tract system imaging [J ] . Chin J Clin Med Imaging , 2022 , 33 ( 2 ): 118 - 121,126 .
Knobloch G , Colgan T , Wang XK , et al . Combined gadoxetic acid and gadobenate dimeglumine enhanced liver MRI:a parameter optimization study [J ] . Abdom Radiol(NY) , 2020 , 45 ( 1 ): 220 - 231 .
Hellms S , Gutberlet M , Peperhove MJ , et al . Applicability of readout-segmented echoplanar diffusion weighted imaging for prostate MRI [J ] . Medicine(Baltimore) , 2019 , 98 ( 29 ): e16447 .
Knobloch G , Nagle S , Colgan T , et al . Feasibility and optimization of ultra-short echo time MRI for improved imaging of IVC filters at 3.0 T [J ] . Abdom Radiol (NY) , 2021 , 46 ( 1 ): 362 - 372 .
Cai Z , Wei Z , Wu M , et al . Knee osteochondral junction imaging using a fast 3D T 1 -weighted ultrashort echo time cones sequence at 3T [J ] . Magn Reson Imaging , 2020 , 73 : 76 - 83 .