Wei Bo,Li Zhiyong,Wang Li,et al.Application of intracardiac echocardiography combined with total three-dimensional technique in zero-fluoroscopy individualized transseptal puncture[J].Journal of Chongqing Medical University,2025,50(3):359-366.
Wei Bo,Li Zhiyong,Wang Li,et al.Application of intracardiac echocardiography combined with total three-dimensional technique in zero-fluoroscopy individualized transseptal puncture[J].Journal of Chongqing Medical University,2025,50(3):359-366. DOI: 10.13406/j.cnki.cyxb.003657.
Application of intracardiac echocardiography combined with total three-dimensional technique in zero-fluoroscopy individualized transseptal puncture
To investigate the feasibility and safety of intracardiac echocardiography(ICE) combined with total three-dimensional(T3D) technique in zero-fluoroscopy individualized transseptal puncture.
Methods
2
A total of 112 patients with atrial fibrillation who underwent radiofrequency ablation in Yongchuan Hospital Affiliated to Chongqing Medical University from April 2021 to March 2024 were enrolled,and according to the method for transseptal puncture,they were randomly divided into ICE+T3D group with 56 patients and ICE group with 56 patients. The two groups were analyzed in terms of baseline data,time to atrial reconstruction,time to coronary sinus electrode placement,frequency of ICE probe adjustment during transseptal puncture,duration of transseptal puncture,pretreatment time before ablation,incidence rate of complications,and the duration and dosage of X-ray exposure.
Results
2
There were no significant differences in baseline data between the two groups. Compared with the ICE group,the ICE+T3D group had a significantly lower frequency of ICE probe adjustment during transseptal puncture(1.70±0.63 vs. 5.34±1.71,
P
<
0.001) and the duration of transseptal puncture(3.66±1.09 min vs. 4.90±1.92 min,
P
<
0.001). Compared with the ICE group,the ICE+T3D group had significantly longer time to atrial reconstruction(22.44±3.13 min vs. 12.34±2.12 min,
P
<
0.001) and pretreatment time before ablation(49.41±3.52 min vs. 37.65±4.04 min,
P
<
0.001). In the ICE+T3D group,43(76.8%) patients achieved
zero radiation during pretreatment before ablation,and 13 patients received X-ray due to the difficulty in catheter placement; compared with the ICE group,the ICE+T3D group had a significantly shorter duration of X-ray exposure(1.68±0.72 min vs. 3.14±1.95 min,
P
=0.010) and a significantly lower dosage of X-ray exposure(6.28±2.78 mGy vs. 23.85±21.32 mGy,
P
=0.004). During the stage of transseptal puncture,all patients in the ICE+T3D group achieved zero radiation,while 45 patients(80.4%) in the ICE patients received X-ray. In terms of complications,there were no life-threatening complications such as cardiac tamponade,perforation of the aorta by mistake,and embolization in either group,while there was one case(1.8%) of vascular complications in each group.
Conclusions
2
ICE combined with T3D after integration and improvement is a safe and reliable procedure for zero-fluoroscopy individualized transseptal puncture.
关键词
Keywords
references
Cha MJ , Jo SJ , Cho Y , et al . Patient characteristics and the incidence of radiation-induced dermatitis following radiofrequency catheter ablation [J ] . Korean Circ J , 2016 , 46 ( 5 ): 646 - 653 .
Ector J , Dragusin O , Adriaenssens B , et al . Obesity is a major determinant of radiation dose in patients undergoing pulmonary vein isolation for atrial fibrillation [J ] . J Am Coll Cardiol , 2007 , 50 ( 3 ): 234 - 242 .
Hang F , Cheng LT , Liang Z , et al . Study on the curative effect and safety of radiofrequency catheter ablation of paroxysmal atrial fibrillation via zero-fluoroscopy transseptal puncture under the dual guidance of electroanatomical mapping and intracardiac echocardiography [J ] . Cardiol Res Pract , 2021 , 2021 : 5561574 .
Wasmer K , Zellerhoff S , Köbe J , et al . Incidence and management of inadvertent puncture and sheath placement in the aorta during attempted transseptal puncture [J ] . Europace , 2017 , 19 ( 3 ): 447 - 457 .
Jan M , Žižek D , Kuhelj D , et al . Combined use of electro-anatomic mapping system and intracardiac echocardiography to achieve zero-fluoroscopy catheter ablation for treatment of paroxysmal atrial fibrillation:a single centre experience [J ] . Int J Cardiovasc Imaging , 2020 , 36 ( 3 ): 415 - 422 .
Bulava A , Hanis J , Eisenberger M . Catheter ablation of atrial fibrillation using zero-fluoroscopy technique:a randomized trial [J ] . Pacing Clin Electrophysiol , 2015 , 38 ( 7 ): 797 - 806 .
Zhong JQ , Long DY , Chu HM , et al . Intracardiac echocardiography Chinese expert consensus [J ] . Front Cardiovasc Med , 2022 , 9 : 1012731 .
Yu RH , Liu N , Lu J , et al . 3-dimensional transseptal puncture based on electrographic characteristics of Fossa ovalis: a fluoroscopy-free and echocardiography-free method [J ] . JACC Cardiovasc Interv , 2020 , 13 ( 10 ): 1223 - 1232 .
Bohnen M , Minners J , Eichenlaub M , et al . Feasibility and safety of a three-dimensional anatomic map-guided transseptal puncture for left-sided catheter ablation procedures [J ] . Europace , 2023 , 25 ( 3 ): 1126 - 1134 .
Chokesuwattanaskul R , Ananwattanasuk T , Hughey AB , et al . Three-dimensional-guided and ICE-guided transseptal puncture for cardiac ablations:a propensity score match study [J ] . J Cardiovasc Electrophysiol , 2023 , 34 ( 2 ): 382 - 388 .
Lerman BB , Markowitz SM , Liu CF , et al . Fluoroless catheter ablation of atrial fibrillation [J ] . Heart Rhythm , 2017 , 14 ( 6 ): 928 - 934 .
Zuo S , Sang CH , Long DY , et al . Feasibility and safety of intracardiac ultrasound-assisted atrial septal puncture during radiofrequency ablation for atrial fibrillation [J ] . Chin J Cardiol , 2021 , 49 ( 5 ): 474 - 478 .
Li D , Yuan CZ , Zhou X , et al . Modified fluorolesstransptal puncture method guided by three-dimensional intracardiac echocardiography [J ] . Chin J Card Pacing Electrophysiol , 2021 , 35 ( 3 ): 234 - 238 .
Zhang GP , Cheng LT , Liang Z , et al . Zero-fluoroscopy transseptal puncture guided by right atrial electroanatomical mapping combined with intracardiac echocardiography:a single-center experience [J ] . Clin Cardiol , 2020 , 43 ( 9 ): 1009 - 1016 .
Hindricks G , Potpara T , Dagres N , et al . 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS):the Task Force for the diagnosis and management of atrial fibrillation of the European Society of Cardiology(ESC) Developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC [J ] . Eur Heart J , 2021 , 42 ( 5 ): 373 - 498 .
Role of tumor necrosis factor-α in regulating the expression and distribution of connexin in the development of atrial fibrillation in rats with sepsis
Construction and validation of a nomogram prediction model for new-onset atrial fibrillation during hospitalization in patients with acute ST-elevation myocardial infarction
Value of advanced lung cancer inflammation index in predicting the prognosis of patients with atrial fibrillation and heart failure
The study of anticoagulation in elderly patients with nonvalvular atrial fibrillation
Related Author
Hua Liwei
Xia Jiading
Zheng Xin
Li Guobin
Xu Min
Zhang Kun
Xiao Jun
Ao Qinrong
Related Institution
Department of Critical Care Medicine,Affiliated Hospital of Chengde Medical University
Department of Cardiovascular Medicine,Chongqing Emergency Medical Center/The Fourth People’s Hospital of Chongqing
Department of Cardiology,The First Affiliated Hospital of Chongqing Medical University
Department of Nursing,Tongji Hospital of Tongji University
Department of Neurology,Tongji Hospital of Tongji University