1.四川省肿瘤临床医学研究中心,四川省肿瘤医院·研究所,四川省癌症防治中心, 电子科技大学附属肿瘤医院影像科,成都 610041
2.山东第一医科大学放射学院,泰安 271000
Received:25 March 2023,
Revised:2023-04-16,
Accepted:27 April 2023,
Published:28 February 2024
移动端阅览
何长久,刘杰克,青浩渺,等.双能量CT非线性融合和噪声优化的虚拟单能量图像技术在喉鳞状细胞癌中的应用[J].重庆医科大学学报,2024,49(2):198-202.
He Changjiu,Liu Jieke,Qing Haomiao,et al.Application of dual-energy CT nonlinear blending and noise-optimized virtual monoenergetic imaging in laryngeal squamous cell carcinoma[J].Journal of Chongqing Medical University,2024,49(2):198-202.
何长久,刘杰克,青浩渺,等.双能量CT非线性融合和噪声优化的虚拟单能量图像技术在喉鳞状细胞癌中的应用[J].重庆医科大学学报,2024,49(2):198-202. DOI: 10.13406/j.cnki.cyxb.003436.
He Changjiu,Liu Jieke,Qing Haomiao,et al.Application of dual-energy CT nonlinear blending and noise-optimized virtual monoenergetic imaging in laryngeal squamous cell carcinoma[J].Journal of Chongqing Medical University,2024,49(2):198-202. DOI: 10.13406/j.cnki.cyxb.003436.
目的
2
探讨双能量CT线性融合图像(linear blending imaging,LBI)、非线性融合图像(nonlinear blending image,NBI)和噪声优化的虚拟单能量图像(noise-optimized virtual monoenergetic image,VMI+)技术在喉鳞状细胞癌中的应用价值。
方法
2
回顾性分析2019年6月至2022年3月61例经病理证实为喉鳞状细胞癌患者的双能量CT资料。双能量图像采用LBI[融合系数为1(80 kV)和0.6(M0.6)]、NBI和VMI+(40 keV、55 keV)技术重建。比较5组图像的客观图像质量[对比噪声比(contrast-to-noise ratio,CNR)、肿瘤CT值、噪声]和主观图像质量(肿瘤边界评分和整体图像质量评分)。
结果
2
40 keV的CNR、肿瘤CT值和肿瘤边界评分均明显高于80 kV、M0.6、NBI和55 keV,差异均有统计学意义(均
P
<
0.05)。NBI的整体图像质量评分明显高于80 kV、M0.6、40 keV和55 keV,差异均有统计学意义(均
P<
0.05)。NBI的噪声明显低于80 kV、40 keV和55 keV,差异均有统计学意义(均
P
<
0.05)。
结论
2
在喉鳞状细胞癌的双能量CT中,采用VMI+技术(40 keV)能提供更好的CNR、肿瘤CT值和肿瘤边界,采用NBI技术能提供更低的噪声和更好的整体图像质量。
Objective
2
To investigate the application value of dual-energy CT(DECT) linear blending imaging(LBI),nonlinear blending imaging(NBI),and noise-optimized virtual monoenergetic imaging(VMI+) techniques in laryngeal squamous cell carcinoma (SCC).
Methods
2
A retrospective analysis was performed for the DECT data of 61 patients with pathologically confirmed laryngeal SCC from June 2019 to March 2022. DECT images were reconstructed using LBI with weighting factors 1 (80 kV) and 0.6(M0.6),NBI,and VMI+(40 keV and 55 keV) techniques. The five groups of images were compared in terms of objective image quality [contrast-to-noise ratio (CNR),tumor CT value,and noise] and subjective image quality(tumor delineation score and overall image quality score).
Results
2
The 40 keV images ha
d significantly higher CNR,tumor CT value,and tumor delineation score than 80 kV,M0.6,NBI,and 55 keV images(all
P
<
0.05). The NBI images had a significantly higher overall image quality score than the 80 kV,M0.6,40 keV,and 55 keV images(all
P
<
0.05). The NBI images had a significantly lower noise than the 80 kV,40 keV,and 55 keV images(all
P
<
0.05).
Conclusion
2
In DECT for laryngeal SCC,the VMI+(40 keV) technique can provide images with better CNR,tumor CT value,and tumor delineation,while the NBI technique can provide images with lower noise and better overall image quality.
雷大鹏 , 潘新良 . 中晚期喉癌的治疗选择 [J ] . 中华耳鼻咽喉头颈外科杂志 , 2019 , 54 ( 5 ): 398 - 400 .
Lei DP , Pan XL . Treatment options for advanced laryngeal carcinoma [J ] . Chin J Otorhinolaryngol Head Neck Surg , 2019 , 54 ( 5 ): 398 - 400 .
Suntharalingam S , Stenzel E , Wetter A , et al . Third generation dual-energy CT with 80/150 Sn kV for head and neck tumor imaging [J ] . Acta Radiol , 2019 , 60 ( 5 ): 586 - 592 .
Zopfs D , Lennartz S , Große Hokamp N , et al . Head and neck squamous cell carcinoma:evaluation of iodine overlay maps and low-energy virtual mono-energetic images acquired with spectral detector CT [J ] . Clin Radiol , 2022 , 77 ( 6 ): e425 - e433 .
Scholtz JE , Hüsers K , Kaup M , et al . Non-linear image blending improves visualization of head and neck primary squamous cell carcinoma compared to linear blending in dual-energy CT [J ] . Clin Radiol , 2015 , 70 ( 2 ): 168 - 175 .
Kraft M , Ibrahim M , Spector M , et al . Comparison of virtual monochromatic series,iodine overlay maps,and single energy CT equivalent images in head and neck cancer conspicuity [J ] . Clin Imaging , 2018 , 48 : 26 - 31 .
Scholtz JE , Kaup M , Kraft J , et al . Objective and subjective image quality of primary and recurrent squamous cell carcinoma on head and neck low-tube-voltage 80-kVp computed tomography [J ] . Neuroradiology , 2015 , 57 ( 6 ): 645 - 651 .
May MS , Wiesmueller M , Heiss R , et al . Comparison of dual- and single-source dual-energy CT in head and neck imaging [J ] . Eur Radiol , 2019 , 29 ( 8 ): 4207 - 4214 .
Tawfik AM , Kerl JM , Bauer RW , et al . Dual-energy CT of head and neck cancer:average weighting of low- and high-voltage acquisitions to improve lesion delineation and image quality-initial clinical experience [J ] . Invest Radiol , 2012 , 47 ( 5 ): 306 - 311 .
Deak PD , Smal Y , Kalender WA . Multisection CT protocols:sex- and age-specific conversion factors used to determine effective dose from dose-length product [J ] . Radiology , 2010 , 257 ( 1 ): 158 - 166 .
Bahig H , Lapointe A , Bedwani S , et al . Dual-energy computed tomography for prediction of loco-regional recurrence after radiotherapy in larynx and hypopharynx squamous cell carcinoma [J ] . Eur J Radiol , 2019 , 110 : 1 - 6 .
Albrecht MH , Scholtz JE , Kraft J , et al . Assessment of an advanced monoenergetic reconstruction technique in dual-energy computed tomography of head and neck cancer [J ] . Eur Radiol , 2015 , 25 ( 8 ): 2493 - 2501 .
Ascenti G , Krauss B , Mazziotti S , et al . Dual-energy computed tomography(DECT)in renal masses:nonlinear versus linear blending [J ] . Acad Radiol , 2012 , 19 ( 10 ): 1186 - 1193 .
He YL , Zhang DM , Xue HD , et al . Clinical value of dual-energy CT in detection of pancreatic adenocarcinoma:investigation of the best pancreatic tumor contrast to noise ratio [J ] . Chung Kuo I Hsueh K'o Hsueh Tsa Chih , 2013 , 27 ( 4 ): 207 - 212 .
余甲乐 , 刘 峰 , 邢 杰 , 等 . 低管电压联合低剂量对比剂在头颈部CT血管成像中的应用 [J ] . 中国医学影像学杂志 , 2022 , 30 ( 4 ): 327 - 332 .
Yu JL , Liu F , Xing J , et al . Application of low tube voltage combined with low dose contrast medium in head and neck CT angiography [J ] . Chin J Med Imag , 2022 , 30 ( 4 ): 327 - 332 .
胡洁婷 , 何 花 , 李雪霜 , 等 . 评价双能量CT非线性融合技术对肾癌诊断的影响 [J ] . 中国医学计算机成像杂志 , 2020 , 26 ( 2 ): 135 - 139 .
Hu JT , He H , Li XS , et al . Evaluating the effect of DECT nonlinear blending technique on the diagnosis of renal cell carcinoma [J ] . Chin Comput Med Imag , 2020 , 26 ( 2 ): 135 - 139 .
Sekiguchi T , Ozawa Y , Hara M , et al . Visibility of the hilar lymph nodes using advanced virtual monoenergetic low-keV images for preoperative evaluation of lung cancer [J ] . Br J Radiol , 2019 , 92 ( 1103 ): 20180734 .
高钦宗 , 王志伟 , 齐亚飞 , 等 . 双层探测器能谱CT虚拟单能量成像在兔VX2肝癌模型微小病灶检测中的价值 [J ] . 中国医学科学院学报 , 2018 , 40 ( 5 ): 651 - 655 .
Gao QZ , Wang ZW , Qi YF , et al . Monoenergetic reconstructions using detector-based spectral CT for imaging of small lesions in the rabbit VX2 liver cancer models [J ] . Acta Acad Med Sin , 2018 , 40 ( 5 ): 651 - 655 .
0
Views
6
下载量
0
CSCD
Publicity Resources
Related Articles
Related Author
Related Institution
京公网安备11010802024621